UPPER FRASER VALLEY TP, Fraser, CO: NPDES CO0040142 discharge permit, effluent exceedances, inspections, penalties

UPPER FRASER VALLEY TP, Fraser, Colorado: Individual permit CO0040142, held by Fraser Town of; Publicly owned treatment works; Administratively continued; issued April 27, 2012, term to May 31, 2017; discharges to FRASER RIVER.

13 of the 51 pollutants listed for NPDES CO0040142 have no violation or effluent exceedance.

  • Zinc, potentially dissolved: 2 limits, 13 violations of any kind, 12 effluent exceedances, latest September 30, 2021, largest 76% over the limit.
  • Nitrogen, ammonia total [as N]: 32 limits, 10 violations of any kind, 8 effluent exceedances, latest January 31, 2024, largest 238% over the limit.
  • BOD, 5-day, 20 deg. C: 6 limits, 5 violations of any kind, 5 effluent exceedances, latest August 31, 2002, largest 91% over the limit.
  • pH: 2 limits, 4 violations of any kind, 4 effluent exceedances, latest January 31, 2007.
  • BOD, 5-day, percent removal: 1 limit, 4 violations of any kind, 4 effluent exceedances, latest August 31, 2002, largest 67% over the limit.
  • %Effect Static Renewal 7 Day Chronic Ceriodaphnia dubia: 0 limits, 9 violations of any kind, 3 effluent exceedances, latest December 31, 2009, largest 99,999% over the limit.
  • %Effect Static Renewal 7Day Chronic Pimephales promelas: 0 limits, 9 violations of any kind, 3 effluent exceedances, latest December 31, 2009, largest 99,999% over the limit.
  • Flow, in conduit or thru treatment plant: 4 limits, 5 violations of any kind, 3 effluent exceedances, latest May 31, 2005, largest 11% over the limit.
  • Copper, total recoverable: 24 limits, 2 violations of any kind, 2 effluent exceedances, latest October 31, 2025, largest 27% over the limit.
  • E. coli: 2 limits, 2 violations of any kind, 2 effluent exceedances, latest June 30, 2026, largest 169% over the limit.
  • Coliform, fecal general: 0 limits, 1 violation of any kind, 1 effluent exceedance, latest July 31, 2002, largest 10% over the limit.
  • Lead, potentially dissolvd: 2 limits, 110 violations of any kind.
  • Nonylphenol: 2 limits, 110 violations of any kind.
  • Selenium, potentially dissolvd: 2 limits, 37 violations of any kind.
  • Silver, potentially dissolved: 2 limits, 24 violations of any kind.
  • Cadmium, potentially dissolvd: 2 limits, 16 violations of any kind.
  • Manganese, dissolved [as Mn]: 2 limits, 12 violations of any kind.
  • Toxicity [chronic], Ceriodaphnia dubia: 0 limits, 6 violations of any kind.
  • Toxicity [chronic], Pimephales promelas [Fathead Minnow]: 0 limits, 6 violations of any kind.
  • Iron, total recoverable: 1 limit, 5 violations of any kind.
  • Solids, total suspended: 4 limits, 4 violations of any kind.
  • Mercury, total [as Hg]: 3 limits, 4 violations of any kind.
  • Static Renewal 7 Day Chronic Ceriodaphnia dubia: 3 limits, 4 violations of any kind.
  • Static Renewal 7 Day Chronic Pimephales promelas: 3 limits, 4 violations of any kind.
  • Cyanide, total [as CN]: 1 limit, 4 violations of any kind.
  • Arsenic, total [as As]: 1 limit, 4 violations of any kind.
  • Cadmium, total [as Cd]: 1 limit, 4 violations of any kind.
  • Chromium, total [as Cr]: 1 limit, 4 violations of any kind.
  • Molybdenum, total [as Mo]: 1 limit, 4 violations of any kind.
  • Lead, total [as Pb]: 1 limit, 3 violations of any kind.
  • Copper, potentially dissolved: 2 limits, 2 violations of any kind.
  • Copper, total [as Cu]: 1 limit, 2 violations of any kind.
  • Nickel, total [as Ni]: 1 limit, 2 violations of any kind.
  • Silver, total [as Ag]: 1 limit, 2 violations of any kind.
  • Phenols: 0 limits, 2 violations of any kind.
  • Solids, total dissolved: 2 limits, 1 violation of any kind.
  • Zinc, total [as Zn]: 1 limit, 1 violation of any kind.
  • Selenium, total [as Se]: 1 limit, 1 violation of any kind.
  • Chromium, hexavalent dissolved [as Cr]: 4 limits.
  • Iron, dissolved [as Fe]: 3 limits.
  • Temperature, water deg. centigrade: 2 limits.
  • Plant capacity fact. percent of capacity: 2 limits.
  • Nitrogen, inorganic total: 2 limits.
  • Cyanide, weak acid, dissociable: 2 limits.
  • Chromium, total recoverable: 2 limits.
  • Chlorine, total residual: 2 limits.
  • Arsenic, total recoverable: 1 limit.
  • Oil and grease: 1 limit.
  • Total phenols: 1 limit.
  • Solids, suspended percent removal: 1 limit.
  • Oil and grease visual: 1 limit.
  • August 21, 2026: Letter of Violation/ Warning Letter (State).

Colorado holds 206 Publicly owned treatment works coverages of this permit type in EPA’s file; 155 were issued before CO0040142. Fraser Town of holds 2 permits in Colorado.

Other permits held by Fraser Town of

Coverages issued nearest CO0040142

UPPER FRASER VALLEY TP among its neighbors

13 discharge permits are in the Middle Fraser River subwatershed (HUC 140100010206); CO0040142 is one. Its county: 104, 4 major; CO0040142 is major permit.

Other permits in the Middle Fraser River subwatershed (HUC 140100010206)

What stands out

  • Its term runs 5 years and 34 days, April 27, 2012 to May 31, 2017; the term ended 3,394 days before EPA's file was loaded on September 15, 2026, and the file lists the permit as administratively continued.
  • Its newest dated event on file is an informal enforcement action on August 21, 2026, 25 days before EPA's file was loaded.
  • In the 365 days to September 15, 2026, it was dated 1 informal enforcement action.
  • EPA's file dates 1 event for it, all in 2026.
  • 11 of its 51 pollutants on file have an effluent exceedance (22%); 45 are under a numeric limit; the largest exceedance is %Effect Static Renewal 7 Day Chronic Ceriodaphnia dubia at 99,999% over its limit.
  • It is one of 8,712 discharge permits on the register in Colorado; 219 of them (2.5%) are in its program, Publicly owned treatment works, and it is a major discharger.

Identity

FacilityUPPER FRASER VALLEY TP
PermitteeFraser Town of
NPDES IDCO0040142
StatusAdministratively continued
TypeIndividual permit
ClassMajor
Facility typePublicly owned treatment works
ProgramPublicly owned treatment works
IssuedApril 27, 2012
ExpiresMay 31, 2017
AddressFraser, CO 80442
Receiving waterFRASER RIVER
SubwatershedMiddle Fraser River (HUC 140100010206)

NPDES CO0040142: effluent limits and exceedances

UPPER FRASER VALLEY TP (NPDES CO0040142): 51 pollutants on file, 45 limited; 38 with a violation of any kind, 11 with an exceedance.

How exceedances are counted.

PollutantLimitsViolationsExceedancesLatestLargest, as filed
Zinc, potentially dissolved21312September 30, 202176% over the limit
Nitrogen, ammonia total [as N]32108January 31, 2024238% over the limit
BOD, 5-day, 20 deg. C655August 31, 200291% over the limit
pH244January 31, 2007
BOD, 5-day, percent removal144August 31, 200267% over the limit
%Effect Static Renewal 7 Day Chronic Ceriodaphnia dubia093December 31, 200999,999% over the limit
%Effect Static Renewal 7Day Chronic Pimephales promelas093December 31, 200999,999% over the limit
Flow, in conduit or thru treatment plant453May 31, 200511% over the limit
Copper, total recoverable2422October 31, 202527% over the limit
E. coli222June 30, 2026169% over the limit
Coliform, fecal general011July 31, 200210% over the limit
Lead, potentially dissolvd21100
Nonylphenol21100
Selenium, potentially dissolvd2370
Silver, potentially dissolved2240
Cadmium, potentially dissolvd2160
Manganese, dissolved [as Mn]2120
Toxicity [chronic], Ceriodaphnia dubia060
Toxicity [chronic], Pimephales promelas [Fathead Minnow]060
Iron, total recoverable150
Solids, total suspended440
Mercury, total [as Hg]340
Static Renewal 7 Day Chronic Ceriodaphnia dubia340
Static Renewal 7 Day Chronic Pimephales promelas340
Cyanide, total [as CN]140
Arsenic, total [as As]140
Cadmium, total [as Cd]140
Chromium, total [as Cr]140
Molybdenum, total [as Mo]140
Lead, total [as Pb]130
Copper, potentially dissolved220
Copper, total [as Cu]120
Nickel, total [as Ni]120
Silver, total [as Ag]120
Phenols020
Solids, total dissolved210
Zinc, total [as Zn]110
Selenium, total [as Se]110
Chromium, hexavalent dissolved [as Cr]400
Iron, dissolved [as Fe]300
Temperature, water deg. centigrade200
Plant capacity fact. percent of capacity200
Nitrogen, inorganic total200
Cyanide, weak acid, dissociable200
Chromium, total recoverable200
Chlorine, total residual200
Arsenic, total recoverable100
Oil and grease100
Total phenols100
Solids, suspended percent removal100
Oil and grease visual100

NPDES CO0040142: inspections, violations and enforcement

NPDES CO0040142: 1 informal enforcement action

DateWhat EPA recordedAgency
August 21, 2026Letter of Violation/ Warning LetterState

NPDES CO0040142 (UPPER FRASER VALLEY TP): no single-event violation, inspection and formal enforcement action on file.

Watch NPDES CO0040142

NPDES CO0040142: one email when its EPA record changes — $99/month.

Billing

Privacy

Permits near NPDES CO0040142

NPDES CO0040142: 51 pollutant rows, 1 dated events; ICIS-NPDES download, loaded September 15, 2026.