Velarion Records
Free: one email when NPDES COG317252 changes. Unsubscribe any time.

NPDES COG317252 · Clean Water Act

DAVIS ST PRESSURE REDUCING VALVE (PRV), Telluride, CO: NPDES COG317252 discharge permit, effluent exceedances, inspections, penalties

DAVIS ST PRESSURE REDUCING VALVE (PRV), Telluride, Colorado: General permit coverage COG317252, held by Telluride Town of; Effective; issued March 20, 2026, term to May 31, 2028; discharges to Cornet Creek & San Miguel River.

No violation or effluent exceedance is on file for any of the 8 pollutants listed for NPDES COG317252.

  • pH: 4 limits.
  • Copper, potentially dissolved: 4 limits.
  • Flow, in conduit or thru treatment plant: 4 limits.
  • Solids, total dissolved: 4 limits.
  • Solids, total suspended: 2 limits.
  • Oil and grease: 2 limits.
  • Flow, total: 2 limits.
  • Oil and grease visual: 2 limits.

Other permits held by Telluride Town of

DAVIS ST PRESSURE REDUCING VALVE (PRV) among its neighbors

23 discharge permits are in the Headwaters San Miguel River subwatershed (HUC 140300030106); COG317252 is one. Its county: 44, 1 major; COG317252 is minor permit.

Other permits in the Headwaters San Miguel River subwatershed (HUC 140300030106)

What stands out

  • Its term runs 2 years and 72 days, March 20, 2026 to May 31, 2028.
  • No dated event in the 365 days to September 15, 2026.
  • It is one of 8,712 discharge permits on the register in Colorado; the file names no program for it, and it is a minor discharger.

Identity

FacilityDAVIS ST PRESSURE REDUCING VALVE (PRV)
PermitteeTelluride Town of
NPDES IDCOG317252
StatusEffective
TypeGeneral permit coverage
ClassMinor
Facility typeNon-POTW
IssuedMarch 20, 2026
ExpiresMay 31, 2028
AddressTelluride, CO 81435
Receiving waterCornet Creek & San Miguel River
SubwatershedHeadwaters San Miguel River (HUC 140300030106)

NPDES COG317252: effluent limits and exceedances

DAVIS ST PRESSURE REDUCING VALVE (PRV) (NPDES COG317252): 8 pollutants on file, 8 limited; 0 with a violation of any kind, 0 with an exceedance.

How exceedances are counted.

PollutantLimitsViolationsExceedancesLatestLargest, as filed
pH400
Copper, potentially dissolved400
Flow, in conduit or thru treatment plant400
Solids, total dissolved400
Solids, total suspended200
Oil and grease200
Flow, total200
Oil and grease visual200

NPDES COG317252: inspections, violations and enforcement

NPDES COG317252 (DAVIS ST PRESSURE REDUCING VALVE (PRV)): no single-event violation, inspection, formal enforcement action and informal enforcement action on file.

Watch NPDES COG317252

NPDES COG317252: one email when its EPA record changes — $99/month.

Billing

Privacy

Permits near NPDES COG317252

NPDES COG317252: 8 pollutant rows, 0 dated events; ICIS-NPDES download, loaded September 15, 2026.