NPDES CT0003701 · Clean Water Act
ALLEGHENY LUDLUM CORPORATION, Wallingford, CT: NPDES CT0003701 discharge permit, effluent exceedances, inspections, penalties
ALLEGHENY LUDLUM CORPORATION, Wallingford, Connecticut: Individual permit CT0003701; Administratively continued; issued June 27, 2001, term to June 26, 2006, by CT DEP; discharges to QUINNIPIAC RIVER.
11 of the 21 pollutants listed for NPDES CT0003701 have no violation or effluent exceedance.
- Lead, total [as Pb]: 10 limits, 39 violations of any kind, 39 effluent exceedances, latest February 28, 2011, largest 466% over the limit.
- Chlorine, total residual: 6 limits, 21 violations of any kind, 21 effluent exceedances, latest July 31, 2002, largest 271% over the limit.
- Nickel, total [as Ni]: 10 limits, 8 violations of any kind, 8 effluent exceedances, latest February 28, 2006, largest 90% over the limit.
- Flow rate: 4 limits, 3 violations of any kind, 3 effluent exceedances, latest September 30, 2002, largest 14% over the limit.
- Solids, total suspended: 7 limits, 2 violations of any kind, 2 effluent exceedances, latest March 31, 2007, largest 95% over the limit.
- Zinc, total [as Zn]: 10 limits, 1 violation of any kind, 1 effluent exceedance, latest February 28, 2007, largest 112% over the limit.
- Flow, maximum during 24 hr period: 4 limits, 1 violation of any kind, 1 effluent exceedance, latest September 30, 2006, largest 4% over the limit.
- Iron, total [as Fe]: 2 limits, 1 violation of any kind, 1 effluent exceedance, latest March 31, 2007, largest 38% over the limit.
- NOAEL Static 48Hr Acute D. pulex: 0 limits, 1 violation of any kind.
- NOAEL Static 48Hr Acute Pimephales promelas: 0 limits, 1 violation of any kind.
- Copper, total [as Cu]: 10 limits.
- pH: 8 limits.
- Pass/Fail Static 48Hr Acute D. Pulex: 8 limits.
- Pass/Fail Static 96 Hr Acute Pimephales Promelas: 8 limits.
- Chromium, total [as Cr]: 4 limits.
- Flow: 4 limits.
- Oil & Grease: 3 limits.
- Nitrogen, ammonia total [as N]: 2 limits.
- Fluoride, total [as F]: 2 limits.
- Chromium, hexavalent [as Cr]: 2 limits.
- Surfactants [MBAS]: 2 limits.
Other permits held by ALLEGHENY LUDLUM CORPORATION
- ALLEGHENY LUDLUM CORPORATION, Waterbury: CTP001395, issued 2006-06-13
ALLEGHENY LUDLUM CORPORATION among its neighbors
27 discharge permits are in the Outlet Quinnipiac River subwatershed (HUC 011000040105); CT0003701 is one. Its county: 202, 21 major; CT0003701 is major permit.
Other permits in the Outlet Quinnipiac River subwatershed (HUC 011000040105)
- ALLNEX USA INCORPORATED, Wallingford: CT0000086, major, term to 2016-05-31
- AMAZON.COM SERVICES LLC - DOB2, Wallingford: CTR050158, minor, term to 2030-09-30
- AMERICAN MEDICAL RESPONSE OF CT INC, New Haven: CTR050322, minor, term to 2030-09-30
- COVIDIEN LP (FORMERLY U S SURGICAL CORP /TYCO HEALTHCARE GROUP), North Haven: CTR050194, minor, term to 2030-09-30
- CT HYPODERMICS, Wallingford: CTR050019, minor, term to 2030-09-30
- FIRST STUDENT, INC. #11845A, New Haven: CTGSI2818, minor, term to 2021-09-30
- FIRST STUDENT, INC. #11845A, New Haven: CTR050242, minor, term to 2030-09-30
- INTERGRATED INDUSTRIAL SYSTEM I2S, Wallingford (Yalesville): CTGSI2837, minor, term to 2021-09-30
- KUEHNE NEW HAVEN LLC, New Haven: CTR050017, minor, term to 2030-09-30
- MERIDEN MAINTENANCE FACILITY, Meriden: CTGVM1101
What stands out
- Its term runs 4 years and 364 days, June 27, 2001 to June 26, 2006; the term ended 7,415 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
- No dated event in the 365 days to October 14, 2026.
- 8 of its 21 pollutants on file have an effluent exceedance (38%); 19 are under a numeric limit; the largest exceedance is Lead, total [as Pb] at 466% over its limit.
- It is one of 1,045 discharge permits on the register in Connecticut; the file names no program for it, and it is a major discharger.
Identity
| Facility | ALLEGHENY LUDLUM CORPORATION |
|---|---|
| Permittee | ALLEGHENY LUDLUM CORPORATION |
| NPDES ID | CT0003701 |
| Status | Administratively continued |
| Type | Individual permit |
| Class | Major |
| Facility type | Non-POTW |
| Issued | June 27, 2001 |
| Expires | June 26, 2006 |
| Agency | CT DEP |
| Address | Wallingford, CT 06492 |
| Receiving water | QUINNIPIAC RIVER |
| Receiving water impaired | 303(D) Listed |
| Subwatershed | Outlet Quinnipiac River (HUC 011000040105) |
| SIC | 3316 – Cold Finishing Of Steel Shapes |
| Other EPA IDs (FRS) | RCRA handler CTD058867656; ICIS-AIR source CT0000000900906505 |
NPDES CT0003701: effluent limits and exceedances
ALLEGHENY LUDLUM CORPORATION (NPDES CT0003701): 21 pollutants on file, 19 limited; 10 with a violation of any kind, 8 with an exceedance.
| Pollutant | Limits | Violations | Exceedances | Latest | Largest, as filed |
|---|---|---|---|---|---|
| Lead, total [as Pb] | 10 | 39 | 39 | February 28, 2011 | 466% over the limit |
| Chlorine, total residual | 6 | 21 | 21 | July 31, 2002 | 271% over the limit |
| Nickel, total [as Ni] | 10 | 8 | 8 | February 28, 2006 | 90% over the limit |
| Flow rate | 4 | 3 | 3 | September 30, 2002 | 14% over the limit |
| Solids, total suspended | 7 | 2 | 2 | March 31, 2007 | 95% over the limit |
| Zinc, total [as Zn] | 10 | 1 | 1 | February 28, 2007 | 112% over the limit |
| Flow, maximum during 24 hr period | 4 | 1 | 1 | September 30, 2006 | 4% over the limit |
| Iron, total [as Fe] | 2 | 1 | 1 | March 31, 2007 | 38% over the limit |
| NOAEL Static 48Hr Acute D. pulex | 0 | 1 | 0 | ||
| NOAEL Static 48Hr Acute Pimephales promelas | 0 | 1 | 0 | ||
| Copper, total [as Cu] | 10 | 0 | 0 | ||
| pH | 8 | 0 | 0 | ||
| Pass/Fail Static 48Hr Acute D. Pulex | 8 | 0 | 0 | ||
| Pass/Fail Static 96 Hr Acute Pimephales Promelas | 8 | 0 | 0 | ||
| Chromium, total [as Cr] | 4 | 0 | 0 | ||
| Flow | 4 | 0 | 0 | ||
| Oil & Grease | 3 | 0 | 0 | ||
| Nitrogen, ammonia total [as N] | 2 | 0 | 0 | ||
| Fluoride, total [as F] | 2 | 0 | 0 | ||
| Chromium, hexavalent [as Cr] | 2 | 0 | 0 | ||
| Surfactants [MBAS] | 2 | 0 | 0 |
NPDES CT0003701: inspections, violations and enforcement
NPDES CT0003701 (ALLEGHENY LUDLUM CORPORATION): no single-event violation, inspection, formal enforcement action and informal enforcement action on file.
Watch NPDES CT0003701
NPDES CT0003701: one email when its EPA record changes — $99/month.
Permits near NPDES CT0003701
NPDES CT0003701: 21 pollutant rows, 0 dated events; ICIS-NPDES download, loaded October 14, 2026.