NPDES CT0100609 · Clean Water Act
VERNON WPCF, Vernon, CT: NPDES CT0100609 discharge permit, effluent exceedances, inspections, penalties
VERNON WPCF, Vernon, Connecticut: Individual permit CT0100609; Publicly owned treatment works; Administratively continued; issued November 10, 2015, term to November 30, 2020, by CT DEP; discharges to HOCKAMAN RIVER.
17 of the 57 pollutants listed for NPDES CT0100609 have no violation or effluent exceedance.
- Oxygen, dissolved [DO]: 1 limit, 113 violations of any kind, 110 effluent exceedances, latest June 30, 2011, largest 99% over the limit.
- Solids, total suspended: 5 limits, 37 violations of any kind, 30 effluent exceedances, latest December 31, 2023, largest 365% over the limit.
- Chlorine, total residual: 4 limits, 38 violations of any kind, 27 effluent exceedances, latest July 31, 2012, largest 13,400% over the limit.
- Coliform, fecal general: 2 limits, 21 violations of any kind, 21 effluent exceedances, latest September 30, 1998, largest 99,999% over the limit.
- Phosphorus, total [as P]: 5 limits, 19 violations of any kind, 19 effluent exceedances, latest April 30, 2024, largest 1,459% over the limit.
- BOD, 5-day, 20 deg. C: 7 limits, 39 violations of any kind, 8 effluent exceedances, latest March 31, 2011, largest 91% over the limit.
- pH: 2 limits, 10 violations of any kind, 3 effluent exceedances, latest April 30, 2022.
- Copper, total [as Cu]: 4 limits, 8 violations of any kind, 3 effluent exceedances, latest December 31, 2023, largest 47% over the limit.
- Flow, in conduit or thru treatment plant: 0 limits, 4 violations of any kind, 3 effluent exceedances, latest January 31, 2004, largest 28% over the limit.
- Solids, settleable: 0 limits, 3 violations of any kind, 3 effluent exceedances, latest March 31, 2001, largest 7,900% over the limit.
- Zinc, total [as Zn]: 4 limits, 7 violations of any kind, 2 effluent exceedances, latest June 30, 2011, largest 11% over the limit.
- BOD, 5-day, percent removal: 1 limit, 3 violations of any kind, 2 effluent exceedances, latest January 31, 1997, largest 50% over the limit.
- E. coli: 2 limits, 5 violations of any kind, 1 effluent exceedance, latest June 30, 2025, largest 88% over the limit.
- Ultraviolet light dosage: 0 limits, 1 violation of any kind, 1 effluent exceedance, latest May 31, 2022, largest 0% over the limit.
- Flow rate: 2 limits, 37 violations of any kind.
- Lead, total [as Pb]: 4 limits, 5 violations of any kind.
- Nitrogen, ammonia total [as N]: 9 limits, 3 violations of any kind.
- Phenols: 2 limits, 2 violations of any kind.
- Pass/Fail Static 48Hr Acute D. Pulex: 0 limits, 2 violations of any kind.
- Cyanide, total [as CN]: 2 limits, 1 violation of any kind.
- Cyanide, free [amenable to chlorination]: 2 limits, 1 violation of any kind.
- Arsenic, total [as As]: 2 limits, 1 violation of any kind.
- Cadmium, total [as Cd]: 2 limits, 1 violation of any kind.
- Chromium, hexavalent [as Cr]: 2 limits, 1 violation of any kind.
- Chromium, total [as Cr]: 2 limits, 1 violation of any kind.
- Thallium, total [as Tl]: 2 limits, 1 violation of any kind.
- Nickel, total [as Ni]: 2 limits, 1 violation of any kind.
- Silver, total [as Ag]: 2 limits, 1 violation of any kind.
- Antimony, total [as Sb]: 2 limits, 1 violation of any kind.
- Selenium, total [as Se]: 2 limits, 1 violation of any kind.
- Mercury, total [as Hg]: 2 limits, 1 violation of any kind.
- Solids, total, percent: 1 limit, 1 violation of any kind.
- Solids, fixed, % of total solids: 1 limit, 1 violation of any kind.
- Solids, suspended percent removal: 1 limit, 1 violation of any kind.
- Turbidity: 0 limits, 1 violation of any kind.
- Nitrogen, nitrite total [as N]: 0 limits, 1 violation of any kind.
- Nitrogen, nitrate total [as N]: 0 limits, 1 violation of any kind.
- Beryllium, total recoverable [as Be]: 0 limits, 1 violation of any kind.
- LC50 Static 48Hr Acute Pimephales promelas: 0 limits, 1 violation of any kind.
- Pass/Fail Static 96 Hr Acute Pimephales Promelas: 0 limits, 1 violation of any kind.
- Beryllium, total [as Be]: 2 limits.
- Iron, total [as Fe]: 2 limits.
- Aluminum, total [as Al]: 2 limits.
- NOAEL Static 48Hr Acute D. pulex: 2 limits.
- NOAEL Static 48Hr Acute Pimephales promelas: 2 limits.
- Polychlorinated biphenyls [PCBs]: 1 limit.
- Phosphorus, Total [Avg Seasonal Load Cap]: 1 limit.
- Arsenic, sludge tot. dry wt [as As]: 1 limit.
- Beryllium, sludge, tot. dry wt [as Be]: 1 limit.
- Solids, volatile % of total solids: 1 limit.
- Zinc, sludge, total, dry weight [as Zn]: 1 limit.
- Lead, sludge, total, dry weight [as Pb]: 1 limit.
- Nickel, sludge, total, dry weight [as Ni]: 1 limit.
- Mercury, sludge, total, dry weight [as Hg]: 1 limit.
- Chromium, sludge, total, dry weight [as Cr]: 1 limit.
- Copper, sludge, total, dry weight [as Cu]: 1 limit.
- Cadmium, sludge, total, dry weight [as Cd]: 1 limit.
- April 17, 2019: Reporting Violations - Improper/ Incorrect Reporting (ST6).
Connecticut holds 84 Publicly owned treatment works coverages of this permit type in EPA’s file; 76 were issued before CT0100609. VERNON WPCF holds 2 permits in Connecticut.
Other permits held by VERNON WPCF
- VERNON WPCF, Vernon: CTL100609, issued 2021-01-01
Coverages issued nearest CT0100609
- 2015-09-28: POQUONOCK WPCF, Windsor: CT0100994, held by POQUONOCK MDC WPCF
- 2015-09-29: NEW CANAAN STP, New Canaan: CT0101273
- 2015-09-30: RIDGEFIELD, TOWN OF (MAIN), Ridgefield: CT0100854
- 2015-10-29: BRIDGEPORT EAST SIDE WPCF, Bridgeport: CT0101010, held by BRIDGEPORT-EAST SIDE WPCF
- 2015-11-02: FAIRFIELD WPCF, Fairfield: CT0101044
- 2016-02-03: GLASTONBURY WPCF, Glastonbury: CT0100226
- 2016-09-29: NEW LONDON WPCF, New London: CT0100382, held by NEW LONDON STP
- 2017-05-17: BEACON FALLS WPCF, Beacon Falls: CT0101061
- 2017-06-05: CANTON WPCF, Canton: CT0100072
- 2017-09-06: DEEP RIVER WPCF, Deep River: CT0101745, held by DEEP RIVER TOWN OF
VERNON WPCF among its neighbors
6 discharge permits are in the Upper Hockanum River subwatershed (HUC 010802050401); CT0100609 is one. Its county: 36, 3 major; CT0100609 is major permit.
Other permits in the Upper Hockanum River subwatershed (HUC 010802050401)
- AMERBELLE CORPORATION, Vernon: CT0020940, minor, term to 1999-05-22
- NATURAL COUNTRY FARMS INC, Ellington: CTR050166, minor, term to 2030-09-30
- ROCKVILLE WATER TREATMENT PLANT, Vernon: CTCSG0010, minor, term to 2025-04-01
- ROCKVILLE WATER TREATMENT PLANT, Vernon Rockville: CTSIU0093, minor, term to 2025-10-30
- VERNON WPCF, Vernon: CTL100609, minor, term to 2025-12-31
Identity
| Facility | VERNON WPCF |
|---|---|
| Permittee | VERNON WPCF |
| NPDES ID | CT0100609 |
| Status | Administratively continued |
| Type | Individual permit |
| Class | Major |
| Facility type | Publicly owned treatment works |
| Program | Publicly owned treatment works |
| Issued | November 10, 2015 |
| Expires | November 30, 2020 |
| Agency | CT DEP |
| Address | Vernon, CT 06066 |
| Receiving water | HOCKAMAN RIVER |
| Receiving water impaired | 303(D) Listed |
| Subwatershed | Upper Hockanum River (HUC 010802050401) |
| Other EPA IDs (FRS) | ICIS-AIR source CT0000000901300167 |
NPDES CT0100609: effluent limits and exceedances
VERNON WPCF (NPDES CT0100609): 57 pollutants on file, 47 limited; 40 with a violation of any kind, 14 with an exceedance.
| Pollutant | Limits | Violations | Exceedances | Latest | Largest, as filed |
|---|---|---|---|---|---|
| Oxygen, dissolved [DO] | 1 | 113 | 110 | June 30, 2011 | 99% over the limit |
| Solids, total suspended | 5 | 37 | 30 | December 31, 2023 | 365% over the limit |
| Chlorine, total residual | 4 | 38 | 27 | July 31, 2012 | 13,400% over the limit |
| Coliform, fecal general | 2 | 21 | 21 | September 30, 1998 | 99,999% over the limit |
| Phosphorus, total [as P] | 5 | 19 | 19 | April 30, 2024 | 1,459% over the limit |
| BOD, 5-day, 20 deg. C | 7 | 39 | 8 | March 31, 2011 | 91% over the limit |
| pH | 2 | 10 | 3 | April 30, 2022 | |
| Copper, total [as Cu] | 4 | 8 | 3 | December 31, 2023 | 47% over the limit |
| Flow, in conduit or thru treatment plant | 0 | 4 | 3 | January 31, 2004 | 28% over the limit |
| Solids, settleable | 0 | 3 | 3 | March 31, 2001 | 7,900% over the limit |
| Zinc, total [as Zn] | 4 | 7 | 2 | June 30, 2011 | 11% over the limit |
| BOD, 5-day, percent removal | 1 | 3 | 2 | January 31, 1997 | 50% over the limit |
| E. coli | 2 | 5 | 1 | June 30, 2025 | 88% over the limit |
| Ultraviolet light dosage | 0 | 1 | 1 | May 31, 2022 | 0% over the limit |
| Flow rate | 2 | 37 | 0 | ||
| Lead, total [as Pb] | 4 | 5 | 0 | ||
| Nitrogen, ammonia total [as N] | 9 | 3 | 0 | ||
| Phenols | 2 | 2 | 0 | ||
| Pass/Fail Static 48Hr Acute D. Pulex | 0 | 2 | 0 | ||
| Cyanide, total [as CN] | 2 | 1 | 0 | ||
| Cyanide, free [amenable to chlorination] | 2 | 1 | 0 | ||
| Arsenic, total [as As] | 2 | 1 | 0 | ||
| Cadmium, total [as Cd] | 2 | 1 | 0 | ||
| Chromium, hexavalent [as Cr] | 2 | 1 | 0 | ||
| Chromium, total [as Cr] | 2 | 1 | 0 | ||
| Thallium, total [as Tl] | 2 | 1 | 0 | ||
| Nickel, total [as Ni] | 2 | 1 | 0 | ||
| Silver, total [as Ag] | 2 | 1 | 0 | ||
| Antimony, total [as Sb] | 2 | 1 | 0 | ||
| Selenium, total [as Se] | 2 | 1 | 0 | ||
| Mercury, total [as Hg] | 2 | 1 | 0 | ||
| Solids, total, percent | 1 | 1 | 0 | ||
| Solids, fixed, % of total solids | 1 | 1 | 0 | ||
| Solids, suspended percent removal | 1 | 1 | 0 | ||
| Turbidity | 0 | 1 | 0 | ||
| Nitrogen, nitrite total [as N] | 0 | 1 | 0 | ||
| Nitrogen, nitrate total [as N] | 0 | 1 | 0 | ||
| Beryllium, total recoverable [as Be] | 0 | 1 | 0 | ||
| LC50 Static 48Hr Acute Pimephales promelas | 0 | 1 | 0 | ||
| Pass/Fail Static 96 Hr Acute Pimephales Promelas | 0 | 1 | 0 | ||
| Beryllium, total [as Be] | 2 | 0 | 0 | ||
| Iron, total [as Fe] | 2 | 0 | 0 | ||
| Aluminum, total [as Al] | 2 | 0 | 0 | ||
| NOAEL Static 48Hr Acute D. pulex | 2 | 0 | 0 | ||
| NOAEL Static 48Hr Acute Pimephales promelas | 2 | 0 | 0 | ||
| Polychlorinated biphenyls [PCBs] | 1 | 0 | 0 | ||
| Phosphorus, Total [Avg Seasonal Load Cap] | 1 | 0 | 0 | ||
| Arsenic, sludge tot. dry wt [as As] | 1 | 0 | 0 | ||
| Beryllium, sludge, tot. dry wt [as Be] | 1 | 0 | 0 | ||
| Solids, volatile % of total solids | 1 | 0 | 0 | ||
| Zinc, sludge, total, dry weight [as Zn] | 1 | 0 | 0 | ||
| Lead, sludge, total, dry weight [as Pb] | 1 | 0 | 0 | ||
| Nickel, sludge, total, dry weight [as Ni] | 1 | 0 | 0 | ||
| Mercury, sludge, total, dry weight [as Hg] | 1 | 0 | 0 | ||
| Chromium, sludge, total, dry weight [as Cr] | 1 | 0 | 0 | ||
| Copper, sludge, total, dry weight [as Cu] | 1 | 0 | 0 | ||
| Cadmium, sludge, total, dry weight [as Cd] | 1 | 0 | 0 |
NPDES CT0100609: inspections, violations and enforcement
NPDES CT0100609: 1 single-event violation
| Date | What EPA recorded | Agency |
|---|---|---|
| April 17, 2019 | Reporting Violations - Improper/ Incorrect Reporting | ST6 |
NPDES CT0100609 (VERNON WPCF): no inspection, formal enforcement action and informal enforcement action on file.
Watch NPDES CT0100609
NPDES CT0100609: one email when its EPA record changes — $99/month.
Permits near NPDES CT0100609
NPDES CT0100609: 57 pollutant rows, 1 dated events; ICIS-NPDES download, loaded September 15, 2026.