PETER PAUL ELECTRONICS CO., INC., New Britain, Connecticut: Individual industrial user permit CTP000778; Administratively continued; issued March 22, 2019, term to March 31, 2024, by CT DEP; discharges to CONNECTICUT RIVER.
3 of the 20 pollutants listed for NPDES CTP000778 have no violation or effluent exceedance.
- Flow rate: 1 limit, 29 violations of any kind, 27 effluent exceedances, latest April 30, 2007, largest 23% over the limit.
- Chromium, total [as Cr]: 3 limits, 8 violations of any kind, 5 effluent exceedances, latest May 31, 2025, largest 447% over the limit.
- Chromium, hexavalent [as Cr]: 5 limits, 6 violations of any kind, 3 effluent exceedances, latest August 31, 2024, largest 370% over the limit.
- Flow: 1 limit, 6 violations of any kind, 3 effluent exceedances, latest May 31, 2019, largest 4% over the limit.
- Flow, maximum during 24 hr period: 2 limits, 5 violations of any kind, 3 effluent exceedances, latest September 30, 2021, largest 10% over the limit.
- Oil petroleum, total recoverable: 3 limits, 2 violations of any kind, 2 effluent exceedances, latest January 31, 2022, largest 86% over the limit.
- pH: 4 limits, 11 violations of any kind, 1 effluent exceedance, latest January 31, 2007.
- pH, maximum: 1 limit, 5 violations of any kind, 1 effluent exceedance, latest April 30, 2025.
- Lead, total [as Pb]: 3 limits, 3 violations of any kind, 1 effluent exceedance, latest July 31, 2020, largest 206% over the limit.
- Copper, total [as Cu]: 3 limits, 2 violations of any kind, 1 effluent exceedance, latest July 31, 2020, largest 259% over the limit.
- Zinc, total [as Zn]: 3 limits, 2 violations of any kind, 1 effluent exceedance, latest July 31, 2020, largest 112% over the limit.
- pH, minimum: 1 limit, 5 violations of any kind.
- Cyanide, total [as CN]: 3 limits, 2 violations of any kind.
- Cadmium, total [as Cd]: 3 limits, 2 violations of any kind.
- Silver, total [as Ag]: 3 limits, 2 violations of any kind.
- Solids, total suspended: 2 limits, 2 violations of any kind.
- Nickel, total [as Ni]: 3 limits, 1 violation of any kind.
- Magnesium, total [as Mg]: 3 limits.
- Phosphorus, total [as P]: 2 limits.
- Organics, total toxic [TTO]: 2 limits.
- December 18, 2025: Permit Violations - Violation Specified in Comment (ST6).
PETER PAUL ELECTRONICS CO., INC. among its neighbors
Its county: 209, 18 major; CTP000778 is minor permit.
Other permits in the county
- 400 FARMINGTON AVE, Farmington: CTGSN2831, minor, term to 2020-09-30
- A. DUIE PYLE COMPANIES, Southington: CTR050076, minor, term to 2030-09-30
- ABBOTT BALL CO, West Hartford: CTR050414, minor, term to 2030-09-30
- ABBOTT BALL COMPANY, West Hartford: CTP000747, minor, term to 2016-10-31
- ABF FREIGHT SYSTEM, INC., Enfield: CTGSI0110, minor, term to 2021-09-30
- ACME-MONACO COPORATION, New Britain: CTP001068, minor, term to 2012-05-31
- AHLSTROM NONWOVENS LLC, Windsor Locks: CT0000434, major, term to 2014-09-30
- AHLSTROM POWER WINDSOR LOCKS, LLC, Windsor Locks: CT0026476, minor, term to 2005-09-29
- AHLSTROM POWER WINDSOR LOCKS, LLC, Windsor Locks: CTP001279, minor, term to 2016-11-30
- ALDI INC - SOUTH WINDSOR DISTRIBUTION CENTER, South Windsor: CTR050115, minor, term to 2030-09-30
What stands out
- Its term runs 5 years and 9 days, March 22, 2019 to March 31, 2024; the term ended 898 days before EPA's file was loaded on September 15, 2026, and the file lists the permit as administratively continued.
- Its newest dated event on file is a single-event violation on December 18, 2025, 271 days before EPA's file was loaded.
- In the 365 days to September 15, 2026, it was dated 1 single-event violation.
- EPA's file dates 1 event for it, all in 2025.
- 11 of its 20 pollutants on file have an effluent exceedance (55%); 20 are under a numeric limit; the largest exceedance is Chromium, total [as Cr] at 447% over its limit.
- It is one of 1,045 discharge permits on the register in Connecticut; the file names no program for it, and it is a minor discharger.
Identity
| Facility | PETER PAUL ELECTRONICS CO., INC. |
|---|---|
| Permittee | PETER PAUL ELECTRONICS CO., INC. |
| NPDES ID | CTP000778 |
| Status | Administratively continued |
| Type | Individual industrial user permit |
| Class | Minor |
| Facility type | Non-POTW |
| Issued | March 22, 2019 |
| Expires | March 31, 2024 |
| Agency | CT DEP |
| Address | New Britain, CT 06050 |
| Receiving water | CONNECTICUT RIVER |
| Other EPA IDs (FRS) | RCRA handler CTD983870015 |
NPDES CTP000778: effluent limits and exceedances
PETER PAUL ELECTRONICS CO., INC. (NPDES CTP000778): 20 pollutants on file, 20 limited; 17 with a violation of any kind, 11 with an exceedance.
| Pollutant | Limits | Violations | Exceedances | Latest | Largest, as filed |
|---|---|---|---|---|---|
| Flow rate | 1 | 29 | 27 | April 30, 2007 | 23% over the limit |
| Chromium, total [as Cr] | 3 | 8 | 5 | May 31, 2025 | 447% over the limit |
| Chromium, hexavalent [as Cr] | 5 | 6 | 3 | August 31, 2024 | 370% over the limit |
| Flow | 1 | 6 | 3 | May 31, 2019 | 4% over the limit |
| Flow, maximum during 24 hr period | 2 | 5 | 3 | September 30, 2021 | 10% over the limit |
| Oil petroleum, total recoverable | 3 | 2 | 2 | January 31, 2022 | 86% over the limit |
| pH | 4 | 11 | 1 | January 31, 2007 | |
| pH, maximum | 1 | 5 | 1 | April 30, 2025 | |
| Lead, total [as Pb] | 3 | 3 | 1 | July 31, 2020 | 206% over the limit |
| Copper, total [as Cu] | 3 | 2 | 1 | July 31, 2020 | 259% over the limit |
| Zinc, total [as Zn] | 3 | 2 | 1 | July 31, 2020 | 112% over the limit |
| pH, minimum | 1 | 5 | 0 | ||
| Cyanide, total [as CN] | 3 | 2 | 0 | ||
| Cadmium, total [as Cd] | 3 | 2 | 0 | ||
| Silver, total [as Ag] | 3 | 2 | 0 | ||
| Solids, total suspended | 2 | 2 | 0 | ||
| Nickel, total [as Ni] | 3 | 1 | 0 | ||
| Magnesium, total [as Mg] | 3 | 0 | 0 | ||
| Phosphorus, total [as P] | 2 | 0 | 0 | ||
| Organics, total toxic [TTO] | 2 | 0 | 0 |
NPDES CTP000778: inspections, violations and enforcement
NPDES CTP000778: 1 single-event violation
| Date | What EPA recorded | Agency |
|---|---|---|
| December 18, 2025 | Permit Violations - Violation Specified in Comment | ST6 |
NPDES CTP000778 (PETER PAUL ELECTRONICS CO., INC.): no inspection, formal enforcement action and informal enforcement action on file.
Watch NPDES CTP000778
NPDES CTP000778: one email when its EPA record changes — $99/month.
Permits near NPDES CTP000778
NPDES CTP000778: 20 pollutant rows, 1 dated events; ICIS-NPDES download, loaded September 15, 2026.