Velarion Records
Free: one email when NPDES CTP001109 changes. Unsubscribe any time.

NPDES CTP001109 · Clean Water Act

UNIFIRST CORPORATION, Stratford, CT: NPDES CTP001109 discharge permit, effluent exceedances, inspections, penalties

UNIFIRST CORPORATION, Stratford, Connecticut: Individual industrial user permit CTP001109; Administratively continued; issued April 3, 2008, term to March 31, 2013, by CT DEP; discharges to HOUSATONIC RIVER.

1 of the 16 pollutants listed for NPDES CTP001109 have no violation or effluent exceedance.

  • Solids, total suspended: 3 limits, 111 violations of any kind, 23 effluent exceedances, latest October 31, 2017, largest 163% over the limit.
  • Zinc, total [as Zn]: 4 limits, 112 violations of any kind, 18 effluent exceedances, latest July 31, 2007, largest 196% over the limit.
  • Organics, volatile [NJAC reg. 7:23-17e]: 0 limits, 102 violations of any kind, 12 effluent exceedances, latest January 31, 2008, largest 805% over the limit.
  • Organics, tot purgeables [Method 624]: 2 limits, 2 violations of any kind, 2 effluent exceedances, latest July 31, 2026, largest 226% over the limit.
  • pH: 4 limits, 94 violations of any kind, 1 effluent exceedance, latest February 28, 2006.
  • Flow rate: 3 limits, 70 violations of any kind, 1 effluent exceedance, latest April 30, 2008, largest 4% over the limit.
  • Copper, total [as Cu]: 4 limits, 94 violations of any kind.
  • Cadmium, total [as Cd]: 4 limits, 92 violations of any kind.
  • Chromium, total [as Cr]: 4 limits, 92 violations of any kind.
  • Lead, total [as Pb]: 4 limits, 92 violations of any kind.
  • BOD, 5-day, 20 deg. C: 2 limits, 92 violations of any kind.
  • Duration of discharge: 0 limits, 92 violations of any kind.
  • Flow: 3 limits, 71 violations of any kind.
  • Flow, maximum during 24 hr period: 3 limits, 1 violation of any kind.
  • pH, maximum: 0 limits, 1 violation of any kind.
  • Oil petroleum, total recoverable: 4 limits.
  • January 15, 2026: Permit Violations - Discharge Without a Valid Permit (ST6).
  • January 15, 2026: Permit Violations - Violation Specified in Comment (ST6).
  • January 15, 2026: Sampling (IU) (S).
  • January 8, 2025: Effluent Violations - Numeric effluent violation (ST6).
  • January 8, 2025: Permit Violations - Violation Specified in Comment (ST6).

UNIFIRST CORPORATION among its neighbors

Its county: 147, 14 major; CTP001109 is minor permit.

Other permits in the county

What stands out

  • Its term runs 4 years and 362 days, April 3, 2008 to March 31, 2013; the term ended 4,916 days before EPA's file was loaded on September 15, 2026, and the file lists the permit as administratively continued.
  • Its newest dated event on file is single-event violation and inspection on January 15, 2026, 243 days before EPA's file was loaded.
  • In the 365 days to September 15, 2026, it was dated 2 single-event violations, 1 inspection.
  • EPA's file dates 5 events for it, from 2025 to 2026; the busiest year is 2026 with 3.
  • 6 of its 16 pollutants on file have an effluent exceedance (38%); 13 are under a numeric limit; the largest exceedance is Organics, volatile [NJAC reg. 7:23-17e] at 805% over its limit.
  • It is one of 1,045 discharge permits on the register in Connecticut; the file names no program for it, and it is a minor discharger.

Identity

FacilityUNIFIRST CORPORATION
PermitteeUNIFIRST CORPORATION
NPDES IDCTP001109
StatusAdministratively continued
TypeIndividual industrial user permit
ClassMinor
Facility typeNon-POTW
IssuedApril 3, 2008
ExpiresMarch 31, 2013
AgencyCT DEP
AddressStratford, CT 06497
Receiving waterHOUSATONIC RIVER
Other EPA IDs (FRS)RCRA handler CTD980670269; ICIS-AIR source CT0000000900108835

NPDES CTP001109: effluent limits and exceedances

UNIFIRST CORPORATION (NPDES CTP001109): 16 pollutants on file, 13 limited; 15 with a violation of any kind, 6 with an exceedance.

How exceedances are counted.

PollutantLimitsViolationsExceedancesLatestLargest, as filed
Solids, total suspended311123October 31, 2017163% over the limit
Zinc, total [as Zn]411218July 31, 2007196% over the limit
Organics, volatile [NJAC reg. 7:23-17e]010212January 31, 2008805% over the limit
Organics, tot purgeables [Method 624]222July 31, 2026226% over the limit
pH4941February 28, 2006
Flow rate3701April 30, 20084% over the limit
Copper, total [as Cu]4940
Cadmium, total [as Cd]4920
Chromium, total [as Cr]4920
Lead, total [as Pb]4920
BOD, 5-day, 20 deg. C2920
Duration of discharge0920
Flow3710
Flow, maximum during 24 hr period310
pH, maximum010
Oil petroleum, total recoverable400

NPDES CTP001109: inspections, violations and enforcement

NPDES CTP001109: 4 single-event violations

DateWhat EPA recordedAgency
January 15, 2026Permit Violations - Discharge Without a Valid PermitST6
January 15, 2026Permit Violations - Violation Specified in CommentST6
January 8, 2025Effluent Violations - Numeric effluent violationST6
January 8, 2025Permit Violations - Violation Specified in CommentST6

NPDES CTP001109: 1 inspection

DateWhat EPA recordedAgency
January 15, 2026Sampling (IU)S

NPDES CTP001109 (UNIFIRST CORPORATION): no formal enforcement action and informal enforcement action on file.

Watch NPDES CTP001109

NPDES CTP001109: one email when its EPA record changes — $99/month.

Billing

Privacy

Permits near NPDES CTP001109

NPDES CTP001109: 16 pollutant rows, 5 dated events; ICIS-NPDES download, loaded September 15, 2026.