Velarion Records
Free: one email when NPDES FL0702820 changes. Unsubscribe any time.

NPDES FL0702820 · Clean Water Act

UNIVERSITY OF SOUTH FLORIDA, Tampa, FL: NPDES FL0702820 discharge permit, effluent exceedances, inspections, penalties

UNIVERSITY OF SOUTH FLORIDA, Tampa, Florida: Individual permit FL0702820, held by University of South Florida; Administratively continued; issued July 6, 2016, term to October 11, 2021, by Florida Department of Environmental Protection; discharges to Hillsborough River Class I WBID 1443H.

  • Oxygen, dissolved [DO]: 2 limits, 15 violations of any kind, 13 effluent exceedances, latest October 31, 2014, largest 72% over the limit.
  • Alkalinity, total [as CaCO3]: 2 limits, 15 violations of any kind, 13 effluent exceedances, latest September 30, 2025, largest 69% over the limit.
  • Specific conductance: 2 limits, 6 violations of any kind, 4 effluent exceedances, latest February 28, 2013, largest 70% over the limit.
  • pH: 4 limits, 7 violations of any kind, 3 effluent exceedances, latest May 31, 2019.
  • Flow, in conduit or thru treatment plant: 6 limits, 6 violations of any kind, 2 effluent exceedances, latest October 31, 2023, largest 50% over the limit.
  • Oxygen, dissolved percent saturation: 2 limits, 4 violations of any kind, 2 effluent exceedances, latest December 31, 2014, largest 66% over the limit.
  • Chlorine, total residual: 2 limits, 3 violations of any kind, 1 effluent exceedance, latest November 30, 2017, largest 200% over the limit.
  • Radium 226 + radium 228, total: 0 limits, 3 violations of any kind, 1 effluent exceedance, latest March 31, 2012, largest 12% over the limit.
  • Alpha, gross particle activity: 0 limits, 3 violations of any kind, 1 effluent exceedance, latest March 31, 2012, largest 5% over the limit.
  • Temperature, water deg. centigrade: 2 limits, 2 violations of any kind.
  • July 22, 2025: Effluent Violations - Industrial Spill (ST6).
  • June 5, 2025: Effluent Violations - Industrial Spill (ST6).
  • September 13, 2021: WW SSO - Overflow to Dry Land or Building Backup (ST6).

UNIVERSITY OF SOUTH FLORIDA among its neighbors

23 discharge permits are in the Cow House Creek subwatershed (HUC 031002050502); FL0702820 is one. Its county: 1,015, 24 major; FL0702820 is minor permit.

Other permits in the Cow House Creek subwatershed (HUC 031002050502)

What stands out

  • Its term runs 5 years and 97 days, July 6, 2016 to October 11, 2021; the term ended 1,800 days before EPA's file was loaded on September 15, 2026, and the file lists the permit as administratively continued.
  • Its newest dated event on file is a single-event violation on July 22, 2025, 420 days before EPA's file was loaded.
  • No dated event in the 365 days to September 15, 2026.
  • EPA's file dates 3 events for it, from 2021 to 2025; the busiest year is 2025 with 2.
  • 9 of its 10 pollutants on file have an effluent exceedance (90%); 8 are under a numeric limit; the largest exceedance is Chlorine, total residual at 200% over its limit.
  • It is one of 23,564 discharge permits on the register in Florida; the file names no program for it, and it is a minor discharger.

Identity

FacilityUNIVERSITY OF SOUTH FLORIDA
PermitteeUniversity of South Florida
NPDES IDFL0702820
StatusAdministratively continued
TypeIndividual permit
ClassMinor
Facility typeNon-POTW
IssuedJuly 6, 2016
ExpiresOctober 11, 2021
AgencyFlorida Department of Environmental Protection
AddressTampa, FL 33620
Receiving waterHillsborough River Class I WBID 1443H
Receiving water impaired303(D) Listed
SubwatershedCow House Creek (HUC 031002050502)
Other EPA IDs (FRS)RCRA handler FLD069687242; ICIS-AIR source FL0000001205700480

NPDES FL0702820: effluent limits and exceedances

UNIVERSITY OF SOUTH FLORIDA (NPDES FL0702820): 10 pollutants on file, 8 limited; 10 with a violation of any kind, 9 with an exceedance.

How exceedances are counted.

PollutantLimitsViolationsExceedancesLatestLargest, as filed
Oxygen, dissolved [DO]21513October 31, 201472% over the limit
Alkalinity, total [as CaCO3]21513September 30, 202569% over the limit
Specific conductance264February 28, 201370% over the limit
pH473May 31, 2019
Flow, in conduit or thru treatment plant662October 31, 202350% over the limit
Oxygen, dissolved percent saturation242December 31, 201466% over the limit
Chlorine, total residual231November 30, 2017200% over the limit
Radium 226 + radium 228, total031March 31, 201212% over the limit
Alpha, gross particle activity031March 31, 20125% over the limit
Temperature, water deg. centigrade220

NPDES FL0702820: inspections, violations and enforcement

NPDES FL0702820: 3 single-event violations

DateWhat EPA recordedAgency
July 22, 2025Effluent Violations - Industrial SpillST6
June 5, 2025Effluent Violations - Industrial SpillST6
September 13, 2021WW SSO - Overflow to Dry Land or Building BackupST6

NPDES FL0702820 (UNIVERSITY OF SOUTH FLORIDA): no inspection, formal enforcement action and informal enforcement action on file.

Watch NPDES FL0702820

NPDES FL0702820: one email when its EPA record changes — $99/month.

Billing

Privacy

Permits near NPDES FL0702820

NPDES FL0702820: 10 pollutant rows, 3 dated events; ICIS-NPDES download, loaded September 15, 2026.