Clean Water Act discharge permit · NPDES GA0021814
TOCCOA, CITY OF (EASTANOLLEE CREEK WPCP), Toccoa, GA: NPDES GA0021814 discharge permit, effluent exceedances, inspections, penalties
- Administratively continuedPermit status
- MajorDischarger class
- 18Pollutants under a numeric limit
- 12Pollutants with an effluent exceedance
- 0Inspections on file
- 0Formal enforcement actions
TOCCOA, CITY OF (EASTANOLLEE CREEK WPCP), held by Toccoa, City of, holds NPDES permit GA0021814. EPA’s file records it issued May 31, 2016 and expiring June 30, 2021. The status and dates are as EPA’s permit file stood when Velarion loaded it (October 14, 2026); EPA’s free Detailed Facility Report on ECHO carries the permit’s current standing.
What stands out
- Its term runs 5 years and 30 days, May 31, 2016 to June 30, 2021; the term ended 1,932 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
- Its newest dated event on file is a single-event violation on October 9, 2026, 5 days before EPA's file was loaded.
- In the 365 days to October 14, 2026, it was dated 2 single-event violations.
- EPA's file dates 2 events for it, all in 2026.
- 12 of its 19 pollutants on file have an effluent exceedance (63%); 18 are under a numeric limit; the largest exceedance is NOEL Static Renewal 7Day Chronic Ceriodaphnia dubia at 99,999% over its limit.
- It is one of 45,725 discharge permits on the register in Georgia; 521 of them (1.1%) are in its program, Publicly owned treatment works, and it is a major discharger.
Identity
| Facility as filed | TOCCOA, CITY OF (EASTANOLLEE CREEK WPCP) |
|---|---|
| Permittee as filed | Toccoa, City of |
| NPDES ID | GA0021814 |
| Permit status | Administratively continued (past its expiration date and still in force until reissued) |
| Permit type | Individual permit |
| Discharger class | Major discharger |
| Facility type | Publicly owned treatment works |
| Program | Publicly owned treatment works |
| Issued | May 31, 2016 |
| Expiration date | June 30, 2021 |
| Address | Toccoa, GA 30577 |
| Subwatershed | Whitewater River (HUC 030601010104) |
| Program components on file | POTW, Pretreatment |
| NAICS | 221320 – Sewage Treatment Facilities |
| SIC | 4952 – Sewerage Systems |
Cited to the EPA ICIS-NPDES permit file (ECHO download) and EPA’s NAICS/SIC and component files, the same download.
Effluent limits and exceedances
- 19Pollutants on file
- 18Under a numeric limit
- 16With a violation of any kind
- 12With an effluent exceedance
An effluent exceedance is a discharge monitoring report value over the permit’s numeric limit (EPA’s violation code E90). A violation of any kind also counts a report not filed. Each row is EPA’s own count for that pollutant.
| Pollutant or measure | Limits | Violations, any kind | Effluent exceedances | Latest exceedance | Largest exceedance, as filed |
|---|---|---|---|---|---|
| Nitrogen, ammonia total [as N] | 8 | 68 | 65 | February 28, 2025 | 740% over the limit |
| Zinc, total recoverable | 0 | 40 | 40 | April 30, 2010 | 632% over the limit |
| Copper, total recoverable | 4 | 35 | 35 | August 31, 2018 | 2,400% over the limit |
| Coliform, fecal general | 2 | 27 | 27 | January 31, 2024 | 560% over the limit |
| pH | 2 | 14 | 14 | February 28, 2025 | |
| Flow, in conduit or thru treatment plant | 2 | 8 | 8 | February 29, 2024 | 10% over the limit |
| Phosphorus, total [as P] | 4 | 7 | 6 | February 29, 2024 | 58% over the limit |
| Solids, suspended percent removal | 1 | 4 | 4 | October 31, 2025 | 93% over the limit |
| Solids, total suspended | 8 | 2 | 2 | February 28, 2019 | 168% over the limit |
| NOEL Static Renewal 7Day Chronic Ceriodaphnia dubia | 1 | 2 | 1 | June 30, 2007 | 99,999% over the limit |
| Oxygen, dissolved [DO] | 1 | 1 | 1 | April 30, 2023 | 20% over the limit |
| BOD, 5-day, percent removal | 1 | 1 | 1 | December 31, 2022 | 47% over the limit |
| Nitrogen, organic total [as N] | 1 | 1 | 0 | ||
| Nitrogen, Kjeldahl, total [as N] | 1 | 1 | 0 | ||
| Nitrite + Nitrate total [as N] | 1 | 1 | 0 | ||
| Noel Statre 7Day Chronic Pimephales | 1 | 1 | 0 | ||
| BOD, 5-day, 20 deg. C | 8 | 0 | 0 | ||
| Phosphorus, ortho | 1 | 0 | 0 | ||
| Solids, sludge, total, dry weight | 1 | 0 | 0 |
Cited to the EPA ICIS-NPDES limits and effluent violations files (ECHO download); up to 60 rows shown, most exceedances first.
Inspections, violations and enforcement
- 2Single-event violations
| Date | What EPA recorded | Agency |
|---|---|---|
| October 9, 2026 | WW SSO - Discharge to Waters | ST6 |
| May 19, 2026 | WW SSO - Discharge to Waters | ST6 |
Inspections
EPA’s inspection file holds no inspection for NPDES GA0021814.
Formal enforcement and penalties
0 formal actions, 0 of them with a penalty assessed. Federal and state penalties are separate figures from separate authorities and are shown as each was filed, never added together.
Informal enforcement
EPA’s informal enforcement file holds no action for NPDES GA0021814.
Cited to the EPA ICIS-NPDES violation, inspection and enforcement files (ECHO download); up to 50 rows of each shown, newest first.
Watch this permit
One permit holder, $99/month. Watch the register for one permit holder and the places and receiving waters tied to its permits. Choose “One permit holder” and enter this permit’s NPDES ID, GA0021814.
Start the watch
- One permit holder — $99/month
- One watershed — $2,990/year
- One state — $4,990/year
- The whole register — $18,000/year
How we handle your data → Privacy
EPA publishes a free Detailed Facility Report for every permit on ECHO: its compliance status quarter by quarter, its inspections, and its enforcement actions and penalties. EPA also sends free notices of new inspections and enforcement actions through ECHO Notify; enter NPDES ID GA0021814 there.
TOCCOA, CITY OF (EASTANOLLEE CREEK WPCP), Toccoa, Georgia: Individual permit GA0021814, held by Toccoa, City of; Publicly owned treatment works; Administratively continued (past its expiration date and still in force until reissued); issued May 31, 2016, term to June 30, 2021; Sewage Treatment Facilities.
3 of the 19 pollutants listed for NPDES GA0021814 have no violation or effluent exceedance.
- Nitrogen, ammonia total [as N]: 8 limits, 68 violations of any kind, 65 effluent exceedances, latest February 28, 2025, largest 740% over the limit.
- Zinc, total recoverable: 0 limits, 40 violations of any kind, 40 effluent exceedances, latest April 30, 2010, largest 632% over the limit.
- Copper, total recoverable: 4 limits, 35 violations of any kind, 35 effluent exceedances, latest August 31, 2018, largest 2,400% over the limit.
- Coliform, fecal general: 2 limits, 27 violations of any kind, 27 effluent exceedances, latest January 31, 2024, largest 560% over the limit.
- pH: 2 limits, 14 violations of any kind, 14 effluent exceedances, latest February 28, 2025.
- Flow, in conduit or thru treatment plant: 2 limits, 8 violations of any kind, 8 effluent exceedances, latest February 29, 2024, largest 10% over the limit.
- Phosphorus, total [as P]: 4 limits, 7 violations of any kind, 6 effluent exceedances, latest February 29, 2024, largest 58% over the limit.
- Solids, suspended percent removal: 1 limit, 4 violations of any kind, 4 effluent exceedances, latest October 31, 2025, largest 93% over the limit.
- Solids, total suspended: 8 limits, 2 violations of any kind, 2 effluent exceedances, latest February 28, 2019, largest 168% over the limit.
- NOEL Static Renewal 7Day Chronic Ceriodaphnia dubia: 1 limit, 2 violations of any kind, 1 effluent exceedance, latest June 30, 2007, largest 99,999% over the limit.
- Oxygen, dissolved [DO]: 1 limit, 1 violation of any kind, 1 effluent exceedance, latest April 30, 2023, largest 20% over the limit.
- BOD, 5-day, percent removal: 1 limit, 1 violation of any kind, 1 effluent exceedance, latest December 31, 2022, largest 47% over the limit.
- Nitrogen, organic total [as N]: 1 limit, 1 violation of any kind.
- Nitrogen, Kjeldahl, total [as N]: 1 limit, 1 violation of any kind.
- Nitrite + Nitrate total [as N]: 1 limit, 1 violation of any kind.
- Noel Statre 7Day Chronic Pimephales: 1 limit, 1 violation of any kind.
- BOD, 5-day, 20 deg. C: 8 limits.
- Phosphorus, ortho: 1 limit.
- Solids, sludge, total, dry weight: 1 limit.
- October 9, 2026: WW SSO - Discharge to Waters (ST6).
- May 19, 2026: WW SSO - Discharge to Waters (ST6).
Georgia holds 458 Publicly owned treatment works coverages of this permit type in EPA’s file; 249 were issued before GA0021814. Toccoa, City of holds 2 permits in Georgia.
Other permits held by Toccoa, City of
- TOCCOA, CITY OF (TOCCOA CREEK WPCP), Toccoa: GA0021806, issued 2015-06-12
Coverages issued nearest GA0021814
- 2016-03-19: ALMA, CITY OF (ALMA WPCP), Alma: GA0032328, held by Alma, City of
- 2016-03-22: FLOWERY BRANCH, CITY OF (FLOWERY BRANCH WPCP), Flowery Branch: GA0031933, held by Flowery Branch, City of
- 2016-05-16: WINDER, CITY OF (MARBURG CREEK WPCP), Winder: GA0023191, held by Winder, City of
- 2016-05-27: BAXLEY, CITY OF (BAXLEY WPCP), Baxley: GA0038725, held by Baxley, City of
- 2016-05-31: TALLAPOOSA, CITY OF (TALLAPOOSA WPCP), Tallapoosa: GA0020982, held by Tallapoosa, City of
- 2016-07-15: ROCKDALE COUNTY WATER RESOURCES (ALMAND BRANCH WPCP), Conyers: GA0021610, held by Rockdale County Water Resources
- 2016-07-21: CONSOLIDATED UTILITIES, INC. (LARCHMONT ESTATES WPCP), Savannah: GA0034819, held by Consolidated Utilities Inc.
- 2016-07-29: NASHVILLE, CITY OF (NASHVILLE WPCP), Nashville: GA0039365, held by Nashville, City of
- 2016-08-15: WALKER COUNTY WATER & SEWER AUTHORITY (WALKER COUNTY WSA WPCP), Chickamauga: GA0020478, held by Walker County Water & Sewerage Authority
- 2016-08-15: CLAYTON COUNTY WATER AUTHORITY (NORTHEAST WRF), Rex: GA0020575, held by Clayton County
TOCCOA, CITY OF (EASTANOLLEE CREEK WPCP) among its neighbors
47 discharge permits are in the Whitewater River subwatershed (HUC 030601010104); GA0021814 is one. Its county: 17, 1 major; GA0021814 is major permit.
Other permits in the Whitewater River subwatershed (HUC 030601010104)
- 6884 TUSQUITTEE ROAD, Hayesville: NCG550427, minor, term to 2025-10-31
- 83 CAREFREE CIRCLE, Sapphire: NCG551100, minor, term to 2025-10-31
- ATHENS Y CAMP CHATTOOGA (ATHENS Y CAMP CHATTOOGA WPCP), Tallulah Falls: GAG550128, minor, term to 2025-03-31
- ATHENS Y CAMP FOR BOYS (ATHENS Y CAMP FOR BOYS WPCP), Tallulah Falls: GAG550004, minor, term to 2025-03-31
- BAD CREEK DRY HOUSE SPOILS, Salem: SCR10ZK13, minor, term to 2030-12-29
- BAD CREEK LAYDOWN, Salem: SCR10ZE94, minor, term to 2028-12-13
- BLACK ROCK ESTATES -LOT 25, Clayton: GAR39777C, minor, term to 2028-07-31
- CEDAR HILL WWTP, Cashiers: NC0068918, minor, term to 2022-08-31
- CHRISTIAN SPIRITUAL ALLIANCE INC. DBA CENTER FOR SPIRITUAL AWARENESS (CENTER FOR, Lakemont: GAG550102, minor, term to 2025-03-31
- DEPARTMENT OF NATURAL RESOURCES (TUGALOO STATE PARK WPCP), Lavonia: GAG550012, minor, term to 2025-03-31
Nearby on the register
- Discharge permits in Toccoa
- Every permit record in Toccoa, A to Z
- Discharge permits in Georgia
- Every permit record in Georgia, A to Z
Figures from EPA’s ICIS-NPDES download, loaded October 14, 2026.
What this page shows
This public-records page covers the Clean Water Act discharge permit NPDES GA0021814 for Toccoa, City of, at the TOCCOA, CITY OF (EASTANOLLEE CREEK WPCP) facility in Toccoa, GA, with a listed status of administratively continued and a major discharger class. The figures listed are 18 pollutants under a numeric limit and 12 pollutants with an effluent exceedance, and the permit's issue date of May 31, 2016 and expiration date of June 30, 2021 are as EPA's permit file stood when the page was loaded.