Velarion Records
Free: one email when NPDES IN0053201 changes. Unsubscribe any time.

NPDES IN0053201 · Clean Water Act

NIPSCO RM SCHAHFER GEN STATION, Wheatfield, IN: NPDES IN0053201 discharge permit, effluent exceedances, inspections, penalties

NIPSCO RM SCHAHFER GEN STATION, Wheatfield, Indiana: Individual permit IN0053201, held by NIPSCO - R M SCHAHFER GEN STATION; Administratively continued; issued September 16, 2015, term to September 30, 2020, by IDEM; discharges to KANKAKEE RIVER & STAUHLBAUM DITCH.

10 of the 34 pollutants listed for NPDES IN0053201 have no violation or effluent exceedance.

  • Solids, total suspended: 26 limits, 86 violations of any kind, 56 effluent exceedances, latest June 30, 2026, largest 165% over the limit.
  • pH: 24 limits, 46 violations of any kind, 15 effluent exceedances, latest September 30, 2024.
  • BOD, carbonaceous [5 day, 20 C]: 2 limits, 24 violations of any kind, 12 effluent exceedances, latest December 31, 2016, largest 293% over the limit.
  • Oil & Grease: 0 limits, 25 violations of any kind, 9 effluent exceedances, latest February 28, 2003, largest 103% over the limit.
  • Zinc, total recoverable: 24 limits, 34 violations of any kind, 8 effluent exceedances, latest April 30, 2002, largest 243% over the limit.
  • E. coli, colony forming units [CFU]: 3 limits, 9 violations of any kind, 8 effluent exceedances, latest May 31, 2026, largest 99,999% over the limit.
  • Chlorine, free available: 0 limits, 13 violations of any kind, 3 effluent exceedances, latest July 31, 1995, largest 100% over the limit.
  • Chlorination duration: 2 limits, 10 violations of any kind, 1 effluent exceedance, latest September 30, 2013, largest 100% over the limit.
  • Chlorine, total residual: 6 limits, 1 violation of any kind, 1 effluent exceedance, latest July 31, 2026, largest 17% over the limit.
  • Flow, in conduit or thru treatment plant: 12 limits, 36 violations of any kind.
  • Oxidants, total residual: 0 limits, 14 violations of any kind.
  • Duration of discharge: 0 limits, 14 violations of any kind.
  • Chromium, total recoverable: 16 limits, 10 violations of any kind.
  • Cadmium, total recoverable: 14 limits, 10 violations of any kind.
  • Lead, total recoverable: 14 limits, 10 violations of any kind.
  • Copper, total recoverable: 14 limits, 10 violations of any kind.
  • Mercury, total recoverable: 10 limits, 10 violations of any kind.
  • Nickel, total recoverable: 14 limits, 8 violations of any kind.
  • Temperature, water deg. fahrenheit: 4 limits, 8 violations of any kind.
  • Chlorination frequency: 2 limits, 8 violations of any kind.
  • Sulfate, total [as SO4]: 18 limits, 4 violations of any kind.
  • Copper, total [as Cu]: 0 limits, 4 violations of any kind.
  • Iron, total [as Fe]: 0 limits, 4 violations of any kind.
  • Flow, total: 2 limits, 2 violations of any kind.
  • Oil and grease, hexane extr method: 24 limits.
  • Arsenic, total recoverable: 24 limits.
  • Selenium, total recoverable: 24 limits.
  • Storm water flow: 14 limits.
  • Nitrogen, ammonia total [as N]: 10 limits.
  • Nitrite + Nitrate total [as N]: 10 limits.
  • Chloride [as Cl]: 10 limits.
  • Boron, total recoverable: 10 limits.
  • Manganese, total recoverable: 10 limits.
  • Number of Events: 2 limits.
  • October 20, 2026: Effluent Violations - Numeric effluent violation (ST6).
  • October 20, 2026: Evaluation (S).
  • October 20, 2026: Evaluation (S).
  • October 20, 2026: Notice of Noncompliance Issued (State).

NIPSCO RM SCHAHFER GEN STATION among its neighbors

11 discharge permits are in the Davis Ditch-Kankakee River subwatershed (HUC 071200010809); IN0053201 is one. Its county: 32, 2 major; IN0053201 is major permit.

Other permits in the Davis Ditch-Kankakee River subwatershed (HUC 071200010809)

What stands out

  • Its term runs 5 years and 14 days, September 16, 2015 to September 30, 2020; the term ended 2,205 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
  • Its newest dated event on file is single-event violation and inspection and informal enforcement action on October 20, 2026.
  • No dated event in the 365 days to October 14, 2026.
  • EPA's file dates 4 events for it, all in 2026.
  • 9 of its 34 pollutants on file have an effluent exceedance (26%); 28 are under a numeric limit; the largest exceedance is E. coli, colony forming units [CFU] at 99,999% over its limit.
  • It is one of 13,164 discharge permits on the register in Indiana; the file names no program for it, and it is a major discharger.

Identity

FacilityNIPSCO RM SCHAHFER GEN STATION
PermitteeNIPSCO - R M SCHAHFER GEN STATION
NPDES IDIN0053201
StatusAdministratively continued
TypeIndividual permit
ClassMajor
Facility typeNon-POTW
IssuedSeptember 16, 2015
ExpiresSeptember 30, 2020
AgencyIDEM
AddressWheatfield, IN 46392
Receiving waterKANKAKEE RIVER & STAUHLBAUM DITCH
Receiving water impaired303(D) Listed
SubwatershedDavis Ditch-Kankakee River (HUC 071200010809)
SIC4911 – Electric Services

NPDES IN0053201: effluent limits and exceedances

NIPSCO RM SCHAHFER GEN STATION (NPDES IN0053201): 34 pollutants on file, 28 limited; 24 with a violation of any kind, 9 with an exceedance.

How exceedances are counted.

PollutantLimitsViolationsExceedancesLatestLargest, as filed
Solids, total suspended268656June 30, 2026165% over the limit
pH244615September 30, 2024
BOD, carbonaceous [5 day, 20 C]22412December 31, 2016293% over the limit
Oil & Grease0259February 28, 2003103% over the limit
Zinc, total recoverable24348April 30, 2002243% over the limit
E. coli, colony forming units [CFU]398May 31, 202699,999% over the limit
Chlorine, free available0133July 31, 1995100% over the limit
Chlorination duration2101September 30, 2013100% over the limit
Chlorine, total residual611July 31, 202617% over the limit
Flow, in conduit or thru treatment plant12360
Oxidants, total residual0140
Duration of discharge0140
Chromium, total recoverable16100
Cadmium, total recoverable14100
Lead, total recoverable14100
Copper, total recoverable14100
Mercury, total recoverable10100
Nickel, total recoverable1480
Temperature, water deg. fahrenheit480
Chlorination frequency280
Sulfate, total [as SO4]1840
Copper, total [as Cu]040
Iron, total [as Fe]040
Flow, total220
Oil and grease, hexane extr method2400
Arsenic, total recoverable2400
Selenium, total recoverable2400
Storm water flow1400
Nitrogen, ammonia total [as N]1000
Nitrite + Nitrate total [as N]1000
Chloride [as Cl]1000
Boron, total recoverable1000
Manganese, total recoverable1000
Number of Events200

NPDES IN0053201: inspections, violations and enforcement

NPDES IN0053201: 1 single-event violation

DateWhat EPA recordedAgency
October 20, 2026Effluent Violations - Numeric effluent violationST6

NPDES IN0053201: 2 inspections

DateWhat EPA recordedAgency
October 20, 2026EvaluationS
October 20, 2026EvaluationS

NPDES IN0053201: 1 informal enforcement action

DateWhat EPA recordedAgency
October 20, 2026Notice of Noncompliance IssuedState

NPDES IN0053201 (NIPSCO RM SCHAHFER GEN STATION): no formal enforcement action on file.

Watch NPDES IN0053201

NPDES IN0053201: one email when its EPA record changes — $99/month.

Billing

Privacy

Permits near NPDES IN0053201

NPDES IN0053201: 34 pollutant rows, 4 dated events; ICIS-NPDES download, loaded October 14, 2026.