Clean Water Act discharge permit · NPDES KS0000604

EVERGY - GORDON EVANS ENERGY CTR, Colwich, KS: NPDES KS0000604 discharge permit, effluent exceedances, inspections, penalties

EVERGY - GORDON EVANS ENERGY CTR, held by EVERGY, INC, holds NPDES permit KS0000604, which discharges to Cowskin Cr (1103001314). EPA’s file records it issued June 1, 2020 and expiring December 31, 2023. The status and dates are as EPA’s permit file stood when Velarion loaded it (October 14, 2026); EPA’s free Detailed Facility Report on ECHO carries the permit’s current standing.

What stands out

  • Its term runs 3 years and 213 days, June 1, 2020 to December 31, 2023; the term ended 1,018 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
  • No dated event in the 365 days to October 14, 2026.
  • 1 of its 9 pollutants on file has an effluent exceedance (11%); 7 are under a numeric limit; the largest exceedance is Lead, total recoverable at 414% over its limit.
  • It is one of 5,445 discharge permits on the register in Kansas; the file names no program for it, and it is a minor discharger.

Identity

Facility as filedEVERGY - GORDON EVANS ENERGY CTR
Permittee as filedEVERGY, INC
NPDES IDKS0000604
Permit statusAdministratively continued (past its expiration date and still in force until reissued)
Permit typeIndividual permit
Discharger classMinor discharger
Facility typeNot a publicly owned treatment works
IssuedJune 1, 2020
Expiration dateDecember 31, 2023
Issuing agencyKansas Department of Health and Environment (KDHE)
AddressColwich, KS 67030
Receiving waterCowskin Cr (1103001314)
SubwatershedHeadwaters Cowskin Creek (HUC 110300130102)
NAICS221112 – Fossil Fuel Electric Power Generation
SIC4911 – Electric Services
Other EPA IDs (FRS)RCRA handler KSD000689877; ICIS-AIR source KS0000002017300012

Cited to the EPA ICIS-NPDES permit file (ECHO download) and EPA’s NAICS/SIC and component files, the same download; cross-program IDs from EPA’s FRS facility-registry crosswalk.

Effluent limits and exceedances

An effluent exceedance is a discharge monitoring report value over the permit’s numeric limit (EPA’s violation code E90). A violation of any kind also counts a report not filed. Each row is EPA’s own count for that pollutant.

Pollutant or measureLimitsViolations, any kindEffluent exceedancesLatest exceedanceLargest exceedance, as filed
Lead, total recoverable111June 30, 2020414% over the limit
Oil & Grease2600
Solids, total suspended2480
Flow, in conduit or thru treatment plant2480
pH2120
Oxidants, total residual0120
Oxidants, free available0120
Temperature, water deg. fahrenheit100
Copper, total recoverable100

Cited to the EPA ICIS-NPDES limits and effluent violations files (ECHO download); up to 60 rows shown, most exceedances first.

Inspections, violations and enforcement

EPA’s single-event violation file, as loaded, holds no violation for NPDES KS0000604.

Inspections

EPA’s inspection file holds no inspection for NPDES KS0000604.

Formal enforcement and penalties

0 formal actions, 0 of them with a penalty assessed. Federal and state penalties are separate figures from separate authorities and are shown as each was filed, never added together.

Informal enforcement

EPA’s informal enforcement file holds no action for NPDES KS0000604.

Cited to the EPA ICIS-NPDES violation, inspection and enforcement files (ECHO download); up to 50 rows of each shown, newest first.

Watch this permit

One permit holder, $99/month. Watch the register for one permit holder and the places and receiving waters tied to its permits. Choose “One permit holder” and enter this permit’s NPDES ID, KS0000604.

Start the watch

How often?
  • One permit holder — $99/month
  • One watershed — $2,990/year
  • One state — $4,990/year
  • The whole register — $18,000/year

How we handle your data → Privacy

EPA publishes a free Detailed Facility Report for every permit on ECHO: its compliance status quarter by quarter, its inspections, and its enforcement actions and penalties. EPA also sends free notices of new inspections and enforcement actions through ECHO Notify; enter NPDES ID KS0000604 there.

EVERGY - GORDON EVANS ENERGY CTR, Colwich, Kansas: Individual permit KS0000604, held by EVERGY, INC; Administratively continued (past its expiration date and still in force until reissued); issued June 1, 2020, term to December 31, 2023, by Kansas Department of Health and Environment (KDHE); discharges to Cowskin Cr (1103001314); Fossil Fuel Electric Power Generation.

2 of the 9 pollutants listed for NPDES KS0000604 have no violation or effluent exceedance.

  • Lead, total recoverable: 1 limit, 1 violation of any kind, 1 effluent exceedance, latest June 30, 2020, largest 414% over the limit.
  • Oil & Grease: 2 limits, 60 violations of any kind.
  • Solids, total suspended: 2 limits, 48 violations of any kind.
  • Flow, in conduit or thru treatment plant: 2 limits, 48 violations of any kind.
  • pH: 2 limits, 12 violations of any kind.
  • Oxidants, total residual: 0 limits, 12 violations of any kind.
  • Oxidants, free available: 0 limits, 12 violations of any kind.
  • Temperature, water deg. fahrenheit: 1 limit.
  • Copper, total recoverable: 1 limit.

EVERGY - GORDON EVANS ENERGY CTR among its neighbors

15 discharge permits are in the Headwaters Cowskin Creek subwatershed (HUC 110300130102); KS0000604 is one. Its county: 662, 5 major; KS0000604 is minor permit.

Other permits in the Headwaters Cowskin Creek subwatershed (HUC 110300130102)

Nearby on the register

Figures from EPA’s ICIS-NPDES download, loaded October 14, 2026.

What this page shows

This public-records page covers NPDES permit KS0000604 for EVERGY - GORDON EVANS ENERGY CTR in Colwich, KS, held by EVERGY, INC, which discharges to Cowskin Cr (1103001314) and is administratively continued. The page lists 7 for the discharger class, 1 pollutant under a numeric limit, and 1 pollutant with an effluent exceedance.