NPDES LA0002925 · Clean Water Act
SOUTHWESTERN ELECTRIC POWER COMPANY - ARSENAL HILL POWER PLANT, Shreveport, LA: NPDES LA0002925 discharge permit, effluent exceedances, inspections, penalties
SOUTHWESTERN ELECTRIC POWER COMPANY - ARSENAL HILL POWER PLANT, Shreveport, Louisiana: Individual permit LA0002925, held by Southwestern Electric Power Company - Arsenal Hill Power Plant; Administratively continued; issued June 18, 2015, term to July 31, 2020; discharges to 1005.
20 of the 32 pollutants listed for NPDES LA0002925 have no violation or effluent exceedance.
- Solids, total suspended: 4 limits, 3 violations of any kind, 3 effluent exceedances, latest January 31, 2013, largest 23% over the limit.
- Temperature, water deg. fahrenheit: 3 limits, 1 violation of any kind, 1 effluent exceedance, latest August 31, 2016, largest 3% over the limit.
- Chromium, total [as Cr]: 4 limits, 4 violations of any kind.
- Pass/Fail Static Renewal 7 Day Chronic Ceriodaphnia dubia: 2 limits, 2 violations of any kind.
- Pass/Fail Static Renewal 7Day Chronic Pimephales promelas: 2 limits, 2 violations of any kind.
- Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Pimephales promelas: 2 limits, 2 violations of any kind.
- NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia: 2 limits, 2 violations of any kind.
- NOEC Lethal Static Renewal 7 Day Chronic Pimephales promelas: 2 limits, 2 violations of any kind.
- NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia: 2 limits, 2 violations of any kind.
- NOEC Sub-Lethal Static Renewal 7 Day Chronic Pimephales promelas: 2 limits, 2 violations of any kind.
- Coef Of Var Static Renewal 7Day Chronic Ceriodaphnia dubia: 2 limits, 2 violations of any kind.
- Coef Of Var Static Renewal 7Day Chronic Pimephales promelas: 2 limits, 2 violations of any kind.
- Whole effluent toxicity - retest #1: 8 limits.
- Whole effluent toxicity - retest #2: 8 limits.
- Flow, in conduit or thru treatment plant: 8 limits.
- Whole Effluent Toxicity - Retest #3: 8 limits.
- pH: 4 limits.
- Copper, total [as Cu]: 4 limits.
- Zinc, total [as Zn]: 4 limits.
- Oil and grease: 4 limits.
- WET, sublethal retest #1: 4 limits.
- WET, sublethal retest #2: 4 limits.
- Chlorine, free available: 4 limits.
- Whole Effluent Toxicity, Sub-Lethal Retest #3: 4 limits.
- Low Flow Pass/Fail Static Renewal 48Hr Acute Daphnia pulex: 2 limits.
- LF Pass/Fail Static Renewal 48Hr Acute Pimephales promelas: 2 limits.
- Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Ceriodaphnia dubia: 2 limits.
- NOAEC Lethal Statis Renewal 48 Hr Acute Daphnia pulex: 2 limits.
- NOAEC Lethal Static Renewal 48Hr acute Pimephales promelas: 2 limits.
- Coef Of Var Static Renewal 48Hr Acute D. pulex: 2 limits.
- Coef Of Var Static Renewal 48Hr Acute Pimephales promelas: 2 limits.
- Chlorine, total residual: 1 limit.
- February 5, 2026: Evaluation (S).
SOUTHWESTERN ELECTRIC POWER COMPANY - ARSENAL HILL POWER PLANT among its neighbors
2 discharge permits are in the Lower Cross Lake-Cross Bayou Outlet subwatershed (HUC 111403040506); LA0002925 is one. Its county: 129, 6 major; LA0002925 is major permit.
Other permits in the Lower Cross Lake-Cross Bayou Outlet subwatershed (HUC 111403040506)
- CENTERPOINT ENERGY RESOURCES CORP - SHREVEPORT LOOP LINE PHASE T 16INCH, Shreveport: LAR10Q170, minor, term to 2026-10-21
What stands out
- Its term runs 5 years and 43 days, June 18, 2015 to July 31, 2020; the term ended 2,237 days before EPA's file was loaded on September 15, 2026, and the file lists the permit as administratively continued.
- Its newest dated event on file is an inspection on February 5, 2026, 222 days before EPA's file was loaded.
- In the 365 days to September 15, 2026, it was dated 1 inspection.
- EPA's file dates 1 event for it, all in 2026.
- 2 of its 32 pollutants on file have an effluent exceedance (6.3%); 32 are under a numeric limit; the largest exceedance is Solids, total suspended at 23% over its limit.
- It is one of 4,455 discharge permits on the register in Louisiana; the file names no program for it, and it is a major discharger.
Identity
| Facility | SOUTHWESTERN ELECTRIC POWER COMPANY - ARSENAL HILL POWER PLANT |
|---|---|
| Permittee | Southwestern Electric Power Company - Arsenal Hill Power Plant |
| NPDES ID | LA0002925 |
| Status | Administratively continued |
| Type | Individual permit |
| Class | Major |
| Facility type | Non-POTW |
| Issued | June 18, 2015 |
| Expires | July 31, 2020 |
| Address | Shreveport, LA 71156 |
| Receiving water | 1005 |
| Receiving water impaired | 303(D) Listed |
| Subwatershed | Lower Cross Lake-Cross Bayou Outlet (HUC 111403040506) |
| Other EPA IDs (FRS) | RCRA handler LAD000820936; ICIS-AIR source LA0000002201700008 |
NPDES LA0002925: effluent limits and exceedances
SOUTHWESTERN ELECTRIC POWER COMPANY - ARSENAL HILL POWER PLANT (NPDES LA0002925): 32 pollutants on file, 32 limited; 12 with a violation of any kind, 2 with an exceedance.
| Pollutant | Limits | Violations | Exceedances | Latest | Largest, as filed |
|---|---|---|---|---|---|
| Solids, total suspended | 4 | 3 | 3 | January 31, 2013 | 23% over the limit |
| Temperature, water deg. fahrenheit | 3 | 1 | 1 | August 31, 2016 | 3% over the limit |
| Chromium, total [as Cr] | 4 | 4 | 0 | ||
| Pass/Fail Static Renewal 7 Day Chronic Ceriodaphnia dubia | 2 | 2 | 0 | ||
| Pass/Fail Static Renewal 7Day Chronic Pimephales promelas | 2 | 2 | 0 | ||
| Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Pimephales promelas | 2 | 2 | 0 | ||
| NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | 2 | 2 | 0 | ||
| NOEC Lethal Static Renewal 7 Day Chronic Pimephales promelas | 2 | 2 | 0 | ||
| NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | 2 | 2 | 0 | ||
| NOEC Sub-Lethal Static Renewal 7 Day Chronic Pimephales promelas | 2 | 2 | 0 | ||
| Coef Of Var Static Renewal 7Day Chronic Ceriodaphnia dubia | 2 | 2 | 0 | ||
| Coef Of Var Static Renewal 7Day Chronic Pimephales promelas | 2 | 2 | 0 | ||
| Whole effluent toxicity - retest #1 | 8 | 0 | 0 | ||
| Whole effluent toxicity - retest #2 | 8 | 0 | 0 | ||
| Flow, in conduit or thru treatment plant | 8 | 0 | 0 | ||
| Whole Effluent Toxicity - Retest #3 | 8 | 0 | 0 | ||
| pH | 4 | 0 | 0 | ||
| Copper, total [as Cu] | 4 | 0 | 0 | ||
| Zinc, total [as Zn] | 4 | 0 | 0 | ||
| Oil and grease | 4 | 0 | 0 | ||
| WET, sublethal retest #1 | 4 | 0 | 0 | ||
| WET, sublethal retest #2 | 4 | 0 | 0 | ||
| Chlorine, free available | 4 | 0 | 0 | ||
| Whole Effluent Toxicity, Sub-Lethal Retest #3 | 4 | 0 | 0 | ||
| Low Flow Pass/Fail Static Renewal 48Hr Acute Daphnia pulex | 2 | 0 | 0 | ||
| LF Pass/Fail Static Renewal 48Hr Acute Pimephales promelas | 2 | 0 | 0 | ||
| Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Ceriodaphnia dubia | 2 | 0 | 0 | ||
| NOAEC Lethal Statis Renewal 48 Hr Acute Daphnia pulex | 2 | 0 | 0 | ||
| NOAEC Lethal Static Renewal 48Hr acute Pimephales promelas | 2 | 0 | 0 | ||
| Coef Of Var Static Renewal 48Hr Acute D. pulex | 2 | 0 | 0 | ||
| Coef Of Var Static Renewal 48Hr Acute Pimephales promelas | 2 | 0 | 0 | ||
| Chlorine, total residual | 1 | 0 | 0 |
NPDES LA0002925: inspections, violations and enforcement
NPDES LA0002925: 1 inspection
| Date | What EPA recorded | Agency |
|---|---|---|
| February 5, 2026 | Evaluation | S |
NPDES LA0002925 (SOUTHWESTERN ELECTRIC POWER COMPANY - ARSENAL HILL POWER PLANT): no single-event violation, formal enforcement action and informal enforcement action on file.
Watch NPDES LA0002925
NPDES LA0002925: one email when its EPA record changes — $99/month.
Permits near NPDES LA0002925
NPDES LA0002925: 32 pollutant rows, 1 dated events; ICIS-NPDES download, loaded September 15, 2026.