ENTERGY LOUISIANA, LLC- NINEMILE POINT GENERATING STATION, Westwego, LA: NPDES LA0003093 discharge permit, effluent exceedances, inspections, penalties

ENTERGY LOUISIANA, LLC- NINEMILE POINT GENERATING STATION, Westwego, Louisiana: Individual permit LA0003093, held by Entergy Louisiana, LLC- Ninemile Point Generating Station; Administratively continued; issued June 9, 2017, term to May 31, 2022; discharges to 0705.

19 of the 34 pollutants listed for NPDES LA0003093 have no violation or effluent exceedance.

  • Solids, total suspended: 10 limits, 16 violations of any kind, 6 effluent exceedances, latest July 31, 2018, largest 277% over the limit.
  • Carbon, tot organic [TOC]: 8 limits, 11 violations of any kind, 3 effluent exceedances, latest June 30, 2015, largest 1,684% over the limit.
  • pH: 6 limits, 17 violations of any kind, 2 effluent exceedances, latest August 31, 2024.
  • Flow, in conduit or thru treatment plant: 28 limits, 35 violations of any kind.
  • Low Flow Pass/Fail Static Renewal 48Hr Acute Daphnia pulex: 0 limits, 30 violations of any kind.
  • LF Pass/Fail Static Renewal 48Hr Acute Pimephales promelas: 0 limits, 30 violations of any kind.
  • NOAEC Lethal Statis Renewal 48 Hr Acute Daphnia pulex: 0 limits, 30 violations of any kind.
  • NOAEC Lethal Static Renewal 48Hr acute Pimephales promelas: 0 limits, 30 violations of any kind.
  • Oil and grease: 11 limits, 19 violations of any kind.
  • Temperature, water deg. fahrenheit: 8 limits, 18 violations of any kind.
  • Chlorine, total residual: 5 limits, 18 violations of any kind.
  • Coef Of Var Static Renewal 48Hr Acute D. pulex: 0 limits, 16 violations of any kind.
  • Coef Of Var Static Renewal 48Hr Acute Pimephales promelas: 0 limits, 16 violations of any kind.
  • Copper, total [as Cu]: 2 limits, 4 violations of any kind.
  • Iron, total [as Fe]: 2 limits, 4 violations of any kind.
  • Whole effluent toxicity - retest #1: 4 limits.
  • Whole effluent toxicity - retest #2: 4 limits.
  • WET, sublethal retest #1: 4 limits.
  • WET, sublethal retest #2: 4 limits.
  • Whole Effluent Toxicity - Retest #3: 4 limits.
  • Whole Effluent Toxicity, Sub-Lethal Retest #3: 4 limits.
  • Oil & Grease: 2 limits.
  • Pass/Fail Static Renewal 7 Day Chronic Ceriodaphnia dubia: 2 limits.
  • Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Ceriodaphnia dubia: 2 limits.
  • Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Pimephales promelas: 2 limits.
  • NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia: 2 limits.
  • NOEC Lethal Static Renewal 7 Day Chronic Pimephales promelas: 2 limits.
  • NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia: 2 limits.
  • NOEC Sub-Lethal Static Renewal 7 Day Chronic Pimephales promelas: 2 limits.
  • Lead, total [as Pb]: 1 limit.
  • Benzene: 1 limit.
  • BTEX: 1 limit.
  • Coef Of Var Static Renewal 7Day Chronic Ceriodaphnia dubia: 1 limit.
  • Coef Of Var Static Renewal 7Day Chronic Pimephales promelas: 1 limit.

ENTERGY LOUISIANA, LLC- NINEMILE POINT GENERATING STATION among its neighbors

70 discharge permits are in the Mississippi River-Bonnet Carre Spillway subwatershed (HUC 080901000101); LA0003093 is one. Its county: 143, 19 major; LA0003093 is major permit.

Other permits in the Mississippi River-Bonnet Carre Spillway subwatershed (HUC 080901000101)

What stands out

  • Its term runs 4 years and 356 days, June 9, 2017 to May 31, 2022; the term ended 1,597 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
  • No dated event in the 365 days to October 14, 2026.
  • 3 of its 34 pollutants on file have an effluent exceedance (8.8%); 28 are under a numeric limit; the largest exceedance is Carbon, tot organic [TOC] at 1,684% over its limit.
  • It is one of 4,455 discharge permits on the register in Louisiana; the file names no program for it, and it is a major discharger.

Identity

FacilityENTERGY LOUISIANA, LLC- NINEMILE POINT GENERATING STATION
PermitteeEntergy Louisiana, LLC- Ninemile Point Generating Station
NPDES IDLA0003093
StatusAdministratively continued
TypeIndividual permit
ClassMajor
Facility typeNon-POTW
IssuedJune 9, 2017
ExpiresMay 31, 2022
AddressWestwego, LA 70094
Receiving water0705
Receiving water impaired303(D) Listed
SubwatershedMississippi River-Bonnet Carre Spillway (HUC 080901000101)
SIC4911 – Electric Services
Other EPA IDs (FRS)RCRA handler LAD069538676; ICIS-AIR source LA0000002205100006

NPDES LA0003093: effluent limits and exceedances

ENTERGY LOUISIANA, LLC- NINEMILE POINT GENERATING STATION (NPDES LA0003093): 34 pollutants on file, 28 limited; 15 with a violation of any kind, 3 with an exceedance.

How exceedances are counted.

PollutantLimitsViolationsExceedancesLatestLargest, as filed
Solids, total suspended10166July 31, 2018277% over the limit
Carbon, tot organic [TOC]8113June 30, 20151,684% over the limit
pH6172August 31, 2024
Flow, in conduit or thru treatment plant28350
Low Flow Pass/Fail Static Renewal 48Hr Acute Daphnia pulex0300
LF Pass/Fail Static Renewal 48Hr Acute Pimephales promelas0300
NOAEC Lethal Statis Renewal 48 Hr Acute Daphnia pulex0300
NOAEC Lethal Static Renewal 48Hr acute Pimephales promelas0300
Oil and grease11190
Temperature, water deg. fahrenheit8180
Chlorine, total residual5180
Coef Of Var Static Renewal 48Hr Acute D. pulex0160
Coef Of Var Static Renewal 48Hr Acute Pimephales promelas0160
Copper, total [as Cu]240
Iron, total [as Fe]240
Whole effluent toxicity - retest #1400
Whole effluent toxicity - retest #2400
WET, sublethal retest #1400
WET, sublethal retest #2400
Whole Effluent Toxicity - Retest #3400
Whole Effluent Toxicity, Sub-Lethal Retest #3400
Oil & Grease200
Pass/Fail Static Renewal 7 Day Chronic Ceriodaphnia dubia200
Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Ceriodaphnia dubia200
Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Pimephales promelas200
NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia200
NOEC Lethal Static Renewal 7 Day Chronic Pimephales promelas200
NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia200
NOEC Sub-Lethal Static Renewal 7 Day Chronic Pimephales promelas200
Lead, total [as Pb]100
Benzene100
BTEX100
Coef Of Var Static Renewal 7Day Chronic Ceriodaphnia dubia100
Coef Of Var Static Renewal 7Day Chronic Pimephales promelas100

NPDES LA0003093: inspections, violations and enforcement

NPDES LA0003093 (ENTERGY LOUISIANA, LLC- NINEMILE POINT GENERATING STATION): no single-event violation, inspection, formal enforcement action and informal enforcement action on file.

Watch NPDES LA0003093

NPDES LA0003093: one email when its EPA record changes — $99/month.

Billing

Privacy

Permits near NPDES LA0003093

NPDES LA0003093: 34 pollutant rows, 0 dated events; ICIS-NPDES download, loaded October 14, 2026.