NPDES MO0099244 · Clean Water Act
USACE STOCKTON POWER HOUSE WWTF, Stockton, MO: NPDES MO0099244 discharge permit, effluent exceedances, inspections, penalties
USACE STOCKTON POWER HOUSE WWTF, Stockton, Missouri: Individual permit MO0099244, held by U.S. Army Corps of Engineers; Administratively continued; issued December 2, 2016, term to December 31, 2018; discharges to Tributary to Sac R..
5 of the 10 pollutants listed for NPDES MO0099244 have no violation or effluent exceedance.
- E. coli: 2 limits, 5 violations of any kind, 5 effluent exceedances, latest June 30, 2020, largest 621% over the limit.
- E. coli, colony forming units [CFU]: 0 limits, 4 violations of any kind, 4 effluent exceedances, latest September 30, 2016, largest 387% over the limit.
- Coliform, fecal general: 0 limits, 4 violations of any kind, 4 effluent exceedances, latest September 30, 2011, largest 525% over the limit.
- BOD, 5-day, 20 deg. C: 2 limits, 2 violations of any kind, 2 effluent exceedances, latest December 31, 2019, largest 13% over the limit.
- Solids, total suspended: 2 limits, 1 violation of any kind, 1 effluent exceedance, latest December 31, 2019, largest 10% over the limit.
- Oxygen, dissolved [DO]: 2 limits.
- pH: 2 limits.
- Nitrogen, ammonia total [as N]: 2 limits.
- Flow, in conduit or thru treatment plant: 2 limits.
- Chlorine, total residual: 2 limits.
Other permits held by U.S. Army Corps of Engineers
- USCOE, TRUMAN VISITOR CENTER WWTP, Warsaw: MO0098744, issued 2017-05-01
- J. F. SPALDING LAND TREATMENT SYSTEM, Monroe City: MO0127183, issued 2018-02-14
- US ARMY CORPS OF ENGINEERS, KANSAS CITY, Kansas City: MOR100043, issued 2012-05-31
- CORA ISLAND CHUTE, West Alton: MORA27218, issued 2024-10-17
USACE STOCKTON POWER HOUSE WWTF among its neighbors
3 discharge permits are in the Stockton Lake Dam-Sac River subwatershed (HUC 102901060703); MO0099244 is one. Its county: 41, 0 major; MO0099244 is minor permit.
Other permits in the Stockton Lake Dam-Sac River subwatershed (HUC 102901060703)
- USACE ORLEANS TRAIL WWTF, Stockton: MO0030287, minor, term to 2023-12-31
- WALNUT HEIGHTS, Stockton: MORA28945, minor, term to 2027-02-07
What stands out
- Its term runs 2 years and 29 days, December 2, 2016 to December 31, 2018; the term ended 2,844 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
- No dated event in the 365 days to October 14, 2026.
- 5 of its 10 pollutants on file have an effluent exceedance (50%); 8 are under a numeric limit; the largest exceedance is E. coli at 621% over its limit.
- It is one of 13,736 discharge permits on the register in Missouri; the file names no program for it, and it is a minor discharger.
Identity
| Facility | USACE STOCKTON POWER HOUSE WWTF |
|---|---|
| Permittee | U.S. Army Corps of Engineers |
| NPDES ID | MO0099244 |
| Status | Administratively continued |
| Type | Individual permit |
| Class | Minor |
| Facility type | Federal facility |
| Issued | December 2, 2016 |
| Expires | December 31, 2018 |
| Address | Stockton, MO 65785 |
| Receiving water | Tributary to Sac R. |
| Subwatershed | Stockton Lake Dam-Sac River (HUC 102901060703) |
| SIC | 4952 – Sewerage Systems |
| Other EPA IDs (FRS) | RCRA handler MOR000032466 |
NPDES MO0099244: effluent limits and exceedances
USACE STOCKTON POWER HOUSE WWTF (NPDES MO0099244): 10 pollutants on file, 8 limited; 5 with a violation of any kind, 5 with an exceedance.
| Pollutant | Limits | Violations | Exceedances | Latest | Largest, as filed |
|---|---|---|---|---|---|
| E. coli | 2 | 5 | 5 | June 30, 2020 | 621% over the limit |
| E. coli, colony forming units [CFU] | 0 | 4 | 4 | September 30, 2016 | 387% over the limit |
| Coliform, fecal general | 0 | 4 | 4 | September 30, 2011 | 525% over the limit |
| BOD, 5-day, 20 deg. C | 2 | 2 | 2 | December 31, 2019 | 13% over the limit |
| Solids, total suspended | 2 | 1 | 1 | December 31, 2019 | 10% over the limit |
| Oxygen, dissolved [DO] | 2 | 0 | 0 | ||
| pH | 2 | 0 | 0 | ||
| Nitrogen, ammonia total [as N] | 2 | 0 | 0 | ||
| Flow, in conduit or thru treatment plant | 2 | 0 | 0 | ||
| Chlorine, total residual | 2 | 0 | 0 |
NPDES MO0099244: inspections, violations and enforcement
NPDES MO0099244 (USACE STOCKTON POWER HOUSE WWTF): no single-event violation, inspection, formal enforcement action and informal enforcement action on file.
Watch NPDES MO0099244
NPDES MO0099244: one email when its EPA record changes — $99/month.
Permits near NPDES MO0099244
NPDES MO0099244: 10 pollutant rows, 0 dated events; ICIS-NPDES download, loaded October 14, 2026.