VAC U JET WWTP, Williston, ND: NPDES NDG426514 discharge permit, effluent exceedances, inspections, penalties

VAC U JET WWTP, Williston, North Dakota: General permit coverage NDG426514, held by Avatas Capital LLC; Administratively continued; issued December 20, 2017, term to December 31, 2022, by North Dakota Department of Environmental Quality; discharges to Little Muddy.

  • pH: 2 limits, 14 violations of any kind, 2 effluent exceedances, latest September 30, 2018.
  • Chlorine, total residual: 3 limits, 22 violations of any kind, 1 effluent exceedance, latest September 30, 2018, largest 100% over the limit.
  • BOD, 5-day, 20 deg. C: 3 limits, 19 violations of any kind, 1 effluent exceedance, latest June 30, 2014, largest 11% over the limit.
  • Solids, total suspended: 3 limits, 19 violations of any kind, 1 effluent exceedance, latest September 30, 2018, largest 3% over the limit.
  • Bromide [as Br]: 3 limits, 21 violations of any kind.
  • Oil & Grease: 3 limits, 18 violations of any kind.
  • Nitrogen, ammonia total [as N]: 3 limits, 18 violations of any kind.
  • Chloride [as Cl]: 3 limits, 18 violations of any kind.
  • Flow, in conduit or thru treatment plant: 2 limits, 13 violations of any kind.
  • E. coli: 3 limits, 9 violations of any kind.
  • Flow, total: 1 limit, 6 violations of any kind.
  • Duration of discharge: 1 limit, 6 violations of any kind.
  • Oil and grease visual: 1 limit, 6 violations of any kind.

VAC U JET WWTP among its neighbors

2 discharge permits are in the Twin Lakes subwatershed (HUC 101101020305); NDG426514 is one. Its county: 152, 1 major; NDG426514 is minor permit.

Other permits in the Twin Lakes subwatershed (HUC 101101020305)

What stands out

  • Its term runs 5 years and 11 days, December 20, 2017 to December 31, 2022; the term ended 1,383 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
  • No dated event in the 365 days to October 14, 2026.
  • 4 of its 13 pollutants on file have an effluent exceedance (31%); 13 are under a numeric limit; the largest exceedance is Chlorine, total residual at 100% over its limit.
  • It is one of 3,594 discharge permits on the register in North Dakota; the file names no program for it, and it is a minor discharger.

Identity

FacilityVAC U JET WWTP
PermitteeAvatas Capital LLC
NPDES IDNDG426514
StatusAdministratively continued
TypeGeneral permit coverage
ClassMinor
Facility typeNon-POTW
IssuedDecember 20, 2017
ExpiresDecember 31, 2022
AgencyNorth Dakota Department of Environmental Quality
AddressWilliston, ND 58801
Receiving waterLittle Muddy
SubwatershedTwin Lakes (HUC 101101020305)

NPDES NDG426514: effluent limits and exceedances

VAC U JET WWTP (NPDES NDG426514): 13 pollutants on file, 13 limited; 13 with a violation of any kind, 4 with an exceedance.

How exceedances are counted.

PollutantLimitsViolationsExceedancesLatestLargest, as filed
pH2142September 30, 2018
Chlorine, total residual3221September 30, 2018100% over the limit
BOD, 5-day, 20 deg. C3191June 30, 201411% over the limit
Solids, total suspended3191September 30, 20183% over the limit
Bromide [as Br]3210
Oil & Grease3180
Nitrogen, ammonia total [as N]3180
Chloride [as Cl]3180
Flow, in conduit or thru treatment plant2130
E. coli390
Flow, total160
Duration of discharge160
Oil and grease visual160

NPDES NDG426514: inspections, violations and enforcement

NPDES NDG426514 (VAC U JET WWTP): no single-event violation, inspection, formal enforcement action and informal enforcement action on file.

Watch NPDES NDG426514

NPDES NDG426514: one email when its EPA record changes — $99/month.

Billing

Privacy

Permits near NPDES NDG426514

NPDES NDG426514: 13 pollutant rows, 0 dated events; ICIS-NPDES download, loaded October 14, 2026.