GANNON & SCOTT, LLC, held by Gannon & Scott, holds NPDES permit RIR50F012, which discharges to Pawtuxet River. EPA’s file records it issued November 15, 2019 and expiring May 2, 2024. The status and dates are as EPA’s permit file stood when Velarion loaded it (October 14, 2026); EPA’s free Detailed Facility Report on ECHO carries the permit’s current standing.
What stands out
- Its term runs 4 years and 169 days, November 15, 2019 to May 2, 2024; the term ended 895 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
- No dated event in the 365 days to October 14, 2026.
- It is one of 642 discharge permits on the register in Rhode Island; 387 of them (60%) are in its program, Industrial stormwater, and it is a minor discharger.
Identity
| Facility as filed | GANNON & SCOTT, LLC |
|---|---|
| Permittee as filed | Gannon & Scott |
| NPDES ID | RIR50F012 |
| Permit status | Administratively continued (past its expiration date and still in force until reissued) |
| Permit type | Coverage under a general permit |
| Discharger class | Minor discharger |
| Facility type | Not a publicly owned treatment works |
| Program | Industrial stormwater |
| Issued | November 15, 2019 |
| Expiration date | May 2, 2024 |
| Issuing agency | RIDEM |
| Address | Cranston, RI 02920 |
| Receiving water | PAWTUXET RIVER |
| Receiving water impaired | 303(D) Listed |
| Subwatershed | Pawtuxet River (HUC 010900040609) |
| NAICS | 331492 – Secondary Smelting, Refining, and Alloying of Nonferrous Metal [except Copper and Aluminum] |
| SIC | 3341 – Secondary Nonferrous Metals |
Cited to the EPA ICIS-NPDES permit file (ECHO download) and EPA’s NAICS/SIC and component files, the same download.
Effluent limits and exceedances
- 5Pollutants on file
- 5Under a numeric limit
- 5With a violation of any kind
- 0With an effluent exceedance
An effluent exceedance is a discharge monitoring report value over the permit’s numeric limit (EPA’s violation code E90). A violation of any kind also counts a report not filed. Each row is EPA’s own count for that pollutant.
| Pollutant or measure | Limits | Violations, any kind | Effluent exceedances | Latest exceedance | Largest exceedance, as filed |
|---|---|---|---|---|---|
| Phosphorus, total [as P] | 2 | 7 | 0 | ||
| Enterococci | 2 | 7 | 0 | ||
| Cadmium, total [as Cd] | 2 | 6 | 0 | ||
| Solids, total suspended | 2 | 2 | 0 | ||
| Oil & Grease | 2 | 2 | 0 |
EPA’s effluent violation file records no exceedance of a numeric limit for NPDES RIR50F012.
Cited to the EPA ICIS-NPDES limits and effluent violations files (ECHO download); up to 60 rows shown, most exceedances first.
Inspections, violations and enforcement
- 0Single-event violations
EPA’s single-event violation file, as loaded, holds no violation for NPDES RIR50F012.
Inspections
EPA’s inspection file holds no inspection for NPDES RIR50F012.
Formal enforcement and penalties
0 formal actions, 0 of them with a penalty assessed. Federal and state penalties are separate figures from separate authorities and are shown as each was filed, never added together.
Informal enforcement
EPA’s informal enforcement file holds no action for NPDES RIR50F012.
Cited to the EPA ICIS-NPDES violation, inspection and enforcement files (ECHO download); up to 50 rows of each shown, newest first.
Watch this permit
One permit holder, $99/month. Watch the register for one permit holder and the places and receiving waters tied to its permits. Choose “One permit holder” and enter this permit’s NPDES ID, RIR50F012.
Start the watch
- One permit holder — $99/month
- One watershed — $2,990/year
- One state — $4,990/year
- The whole register — $18,000/year
How we handle your data → Privacy
EPA publishes a free Detailed Facility Report for every permit on ECHO: its compliance status quarter by quarter, its inspections, and its enforcement actions and penalties. EPA also sends free notices of new inspections and enforcement actions through ECHO Notify; enter NPDES ID RIR50F012 there.
GANNON & SCOTT, LLC, Cranston, Rhode Island: Coverage under a general permit RIR50F012, held by Gannon & Scott; Industrial stormwater; Administratively continued (past its expiration date and still in force until reissued); issued November 15, 2019, term to May 2, 2024, by RIDEM; discharges to PAWTUXET RIVER; Secondary Smelting, Refining, and Alloying of Nonferrous Metal [except Copper and Aluminum].
- Phosphorus, total [as P]: 2 limits, 7 violations of any kind.
- Enterococci: 2 limits, 7 violations of any kind.
- Cadmium, total [as Cd]: 2 limits, 6 violations of any kind.
- Solids, total suspended: 2 limits, 2 violations of any kind.
- Oil & Grease: 2 limits, 2 violations of any kind.
Rhode Island holds 370 Industrial stormwater coverages of this permit type in EPA’s file; 172 were issued before RIR50F012.
Coverages issued nearest RIR50F012
- 2019-10-29: DEAN WAREHOUSE SERVICES, Cumberland: RIR50P027, held by BERKELEY ACQUISITION CORPORATION
- 2019-10-29: FOOLPROOF BREWING COMPANY LLC, Pawtucket: RIRND0005, held by Foolproof Brewing Company LLC
- 2019-10-30: LEONARD VALVE, Cranston: RIRNE0322, held by Richard Cota Jr.
- 2019-11-01: INDUPLATE LLC (3471 PLATING), North Providence: RIRNE0323, held by Induplate LLC
- 2019-11-13: PLASTIC RECYCLING, Woonsocket: RIRNE0324, held by C & C Plastics Co Inc
- 2019-11-20: AMERICAN MUSSEL HARVESTERS, INC., North Kingstown: RIRNE0326, held by American Mussel Harvesters, Inc.
- 2019-11-21: CONSOLIDATED CONCRETE CORP., E. Providence: RIR50E002, held by CONSOLIDATED CONCRETE CORPORATION
- 2019-11-21: DON'S MARINE, Tiverton: RIRND0006
- 2019-11-23: CATHEDRAL ART, Providence: RIRNE0327, held by Ken Snedeker
- 2019-11-30: TAPPED APPLE CIDERY & WINERY, Westerly: RIRNE0328, held by John H Wiedenheft III
GANNON & SCOTT, LLC among its neighbors
63 discharge permits are in the Pawtuxet River subwatershed (HUC 010900040609); RIR50F012 is one. Its county: 219, 10 major; RIR50F012 is minor permit.
Other permits in the Pawtuxet River subwatershed (HUC 010900040609)
- 10 PARK LANE, PROVIDENCE, Providence: RIR060007, minor, term to 2031-03-31
- 1011 & 1015 CRANSTON STREET, Cranston: RIR100673, minor, term to 2008-09-09
- 1011 CRANSTON ST., CRANSTON, Cranston: RIR060003, minor, term to 2031-03-31
- 225 NIANTIC AVE, CRANSTON, Cranston: RIR060002, minor, term to 2031-03-31
- 28 HARRIS AVENUE, CRANSTON, Cranston: RIR060001, minor, term to 2031-03-31
- ADVANCED CHEMICAL CO INC, Warwick: RIR50F009, minor, term to 2024-05-02
- ALLIED, Providence: RIRNE0421, minor, term to 2029-04-17
- ALLIED, Cranston: RIRNE0422, minor, term to 2029-04-17
- AMAZON.COM SERVICES LLC - DRI1, Providence: RIR50P047, minor, term to 2024-05-02
- AMAZON.COM SERVICES LLC - DRI1_2, Providence: RIR50P048, minor, term to 2024-05-02
Nearby on the register
- Discharge permits in Cranston
- Every permit record in Cranston, A to Z
- Discharge permits in Rhode Island
- Every permit record in Rhode Island, A to Z
Figures from EPA’s ICIS-NPDES download, loaded October 14, 2026.
What this page shows
This public-records page covers NPDES permit RIR50F012 held by GANNON & SCOTT, LLC of Cranston, RI, an industrial stormwater permit administratively continued after its May 2, 2024 expiration, with a Pawtuxet River receiving water listed as impaired under 303(D). The page lists 0 pollutants under a numeric limit and 0 pollutants with an effluent exceedance, and it records a Minor Discharger class with the Pawtuxet River subwatershed HUC 010900040609.