NPDES SC0001848 · Clean Water Act
WESTINGHOUSE ELECTRIC COMPANY LLC, COLUMBIA FUEL FABRICATION FACILITY, Hopkins, SC: NPDES SC0001848 discharge permit, effluent exceedances, inspections, penalties
WESTINGHOUSE ELECTRIC COMPANY LLC, COLUMBIA FUEL FABRICATION FACILITY, Hopkins, South Carolina: Individual permit SC0001848, held by Westinghouse Electric Company LLC; Administratively continued; issued March 30, 2017, term to March 31, 2018, by State; Other Basic Inorganic Chemical Manufacturing.
3 of the 14 pollutants listed for NPDES SC0001848 have no violation or effluent exceedance.
- BOD, 5-day, 20 deg. C: 8 limits, 11 violations of any kind, 7 effluent exceedances, latest May 31, 2022, largest 75% over the limit.
- Chlorine, total residual: 4 limits, 5 violations of any kind, 4 effluent exceedances, latest April 30, 2019, largest 35% over the limit.
- Coliform, fecal general: 4 limits, 5 violations of any kind, 3 effluent exceedances, latest September 30, 2016, largest 505% over the limit.
- Solids, total suspended: 8 limits, 6 violations of any kind, 2 effluent exceedances, latest April 30, 2010, largest 46% over the limit.
- Oxygen, dissolved [DO]: 2 limits, 3 violations of any kind, 2 effluent exceedances, latest July 31, 2026, largest 6% over the limit.
- Nitrogen, ammonia total [as N]: 8 limits, 1 violation of any kind, 1 effluent exceedance, latest July 31, 2008, largest 16% over the limit.
- pH: 4 limits, 2 violations of any kind.
- Phosphorus, total [as P]: 4 limits, 2 violations of any kind.
- Flow, in conduit or thru treatment plant: 4 limits, 2 violations of any kind.
- Length of longest pH excursion: 2 limits, 1 violation of any kind.
- % of time exceeding pH limits: 2 limits, 1 violation of any kind.
- Fluoride, total [as F]: 2 limits.
- E. coli: 2 limits.
- %Effect Static Renewal 7 Day Chronic Ceriodaphnia dubia: 2 limits.
- July 23, 2026: Notice of Violation (State).
- July 1, 2020: Permit Violations - Violation Specified in Comment (ST6).
- January 25, 2019: Permit Violations - Violation Specified in Comment (ST6).
WESTINGHOUSE ELECTRIC COMPANY LLC, COLUMBIA FUEL FABRICATION FACILITY among its neighbors
48 discharge permits are in the Middle Congaree River subwatershed (HUC 030501100303); SC0001848 is one. Its county: 791, 6 major; SC0001848 is major permit.
Other permits in the Middle Congaree River subwatershed (HUC 030501100303)
- 134 ACCESS ROAD TRUCK SHOP, Gaston: SCR10ZDVH, minor, term to 2028-10-09
- 321 AUTO SALES- PARKING EXPANSION, Gaston: SCR10ZEB4, minor, term to 2028-12-26
- ACCESS MATERIALS CLASS 2 LANDFILL, Gaston: SCR10ZL7A, minor, term to 2031-06-14
- AGP E-GLASS COMPANY, West Columbia: SCRNE0989, minor, term to 2028-07-11
- ALLTAPE ADHESIVE MANUFACTURER, INC., West Columbia: SCRNE1225, minor, term to 2031-06-09
- ALPEK POLYESTER USA, LLC, Gaston: SC0001333, major, term to 2023-10-31
- BUILDING PAD ON PARCEL 11 AT THE SAXE GOTHA INDUSTRIAL PARK, Lexington: SCR10ZBJJ, minor, term to 2027-10-11
- CALHOUN COUNTY I-26 REST STOP WWTP, St Matthews: SCG570038, minor, term to 2018-12-31
- CAYCE WWTP, Cayce: SC0024147, major, term to 2023-05-31
- CHICK-FIL-A SUPPLY DC - WEST COLUMBIA, SC, West Columbia: SCR006977, minor, term to 2027-06-30
What stands out
- Its term runs 1 year and 1 day, March 30, 2017 to March 31, 2018; the term ended 3,119 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
- Its newest dated event on file is an informal enforcement action on July 23, 2026, 83 days before EPA's file was loaded.
- In the 365 days to October 14, 2026, it was dated 1 informal enforcement action.
- EPA's file dates 3 events for it, from 2019 to 2026.
- 6 of its 14 pollutants on file have an effluent exceedance (43%); 14 are under a numeric limit; the largest exceedance is Coliform, fecal general at 505% over its limit.
- It is one of 13,763 discharge permits on the register in South Carolina; the file names no program for it, and it is a major discharger.
Identity
| Facility | WESTINGHOUSE ELECTRIC COMPANY LLC, COLUMBIA FUEL FABRICATION FACILITY |
|---|---|
| Permittee | Westinghouse Electric Company LLC |
| NPDES ID | SC0001848 |
| Status | Administratively continued |
| Type | Individual permit |
| Class | Major |
| Facility type | Non-POTW |
| Issued | March 30, 2017 |
| Expires | March 31, 2018 |
| Agency | State |
| Address | Hopkins, SC 29061 |
| Subwatershed | Middle Congaree River (HUC 030501100303) |
| NAICS | 325180 – Other Basic Inorganic Chemical Manufacturing |
| SIC | 2819 – Industrial Inorganic Chemicals |
| Other EPA IDs (FRS) | RCRA handler SCD047559331; ICIS-AIR source SC00019000050 |
NPDES SC0001848: effluent limits and exceedances
WESTINGHOUSE ELECTRIC COMPANY LLC, COLUMBIA FUEL FABRICATION FACILITY (NPDES SC0001848): 14 pollutants on file, 14 limited; 11 with a violation of any kind, 6 with an exceedance.
| Pollutant | Limits | Violations | Exceedances | Latest | Largest, as filed |
|---|---|---|---|---|---|
| BOD, 5-day, 20 deg. C | 8 | 11 | 7 | May 31, 2022 | 75% over the limit |
| Chlorine, total residual | 4 | 5 | 4 | April 30, 2019 | 35% over the limit |
| Coliform, fecal general | 4 | 5 | 3 | September 30, 2016 | 505% over the limit |
| Solids, total suspended | 8 | 6 | 2 | April 30, 2010 | 46% over the limit |
| Oxygen, dissolved [DO] | 2 | 3 | 2 | July 31, 2026 | 6% over the limit |
| Nitrogen, ammonia total [as N] | 8 | 1 | 1 | July 31, 2008 | 16% over the limit |
| pH | 4 | 2 | 0 | ||
| Phosphorus, total [as P] | 4 | 2 | 0 | ||
| Flow, in conduit or thru treatment plant | 4 | 2 | 0 | ||
| Length of longest pH excursion | 2 | 1 | 0 | ||
| % of time exceeding pH limits | 2 | 1 | 0 | ||
| Fluoride, total [as F] | 2 | 0 | 0 | ||
| E. coli | 2 | 0 | 0 | ||
| %Effect Static Renewal 7 Day Chronic Ceriodaphnia dubia | 2 | 0 | 0 |
NPDES SC0001848: inspections, violations and enforcement
NPDES SC0001848: 2 single-event violations
| Date | What EPA recorded | Agency |
|---|---|---|
| July 1, 2020 | Permit Violations - Violation Specified in Comment | ST6 |
| January 25, 2019 | Permit Violations - Violation Specified in Comment | ST6 |
NPDES SC0001848: 1 informal enforcement action
| Date | What EPA recorded | Agency |
|---|---|---|
| July 23, 2026 | Notice of Violation | State |
NPDES SC0001848 (WESTINGHOUSE ELECTRIC COMPANY LLC, COLUMBIA FUEL FABRICATION FACILITY): no inspection and formal enforcement action on file.
Watch NPDES SC0001848
NPDES SC0001848: one email when its EPA record changes — $99/month.
Permits near NPDES SC0001848
NPDES SC0001848: 14 pollutant rows, 3 dated events; ICIS-NPDES download, loaded October 14, 2026.