NPDES TN0020672 · Clean Water Act
ROGERSVILLE STP, Rogersville, TN: NPDES TN0020672 discharge permit, effluent exceedances, inspections, penalties
ROGERSVILLE STP, Rogersville, Tennessee: Individual permit TN0020672, held by Town of Rogersville; Publicly owned treatment works; Administratively continued; issued November 29, 2019, term to December 31, 2024, by TDEC - DWR; discharges to Holston; Sewage Treatment Facilities.
4 of the 23 pollutants listed for NPDES TN0020672 have no violation or effluent exceedance.
- Solids, total suspended: 7 limits, 80 violations of any kind, 80 effluent exceedances, latest November 30, 2021, largest 804% over the limit.
- BOD, 5-day, 20 deg. C: 7 limits, 31 violations of any kind, 31 effluent exceedances, latest February 29, 2020, largest 662% over the limit.
- Solids, suspended percent removal: 2 limits, 26 violations of any kind, 26 effluent exceedances, latest February 29, 2020, largest 120% over the limit.
- SSO, Dry Weather: 3 limits, 21 violations of any kind, 19 effluent exceedances, latest March 31, 2026, largest 2,147,483,650% over the limit.
- E. coli, MTEC-MF: 0 limits, 18 violations of any kind, 18 effluent exceedances, latest February 28, 2019, largest 697% over the limit.
- SSO, Wet Weather: 3 limits, 18 violations of any kind, 16 effluent exceedances, latest January 31, 2026, largest 2,147,483,650% over the limit.
- BOD, 5-day, percent removal: 2 limits, 7 violations of any kind, 7 effluent exceedances, latest February 28, 2025, largest 200% over the limit.
- Coliform, fecal MF, MFC broth, 44.5 C: 0 limits, 4 violations of any kind, 4 effluent exceedances, latest March 31, 2009, largest 375% over the limit.
- pH: 2 limits, 2 violations of any kind, 2 effluent exceedances, latest March 31, 2014.
- Solids, settleable: 1 limit, 2 violations of any kind, 2 effluent exceedances, latest May 31, 2014, largest 900% over the limit.
- LC50 Static 48Hr Acute Ceriodaphnia dubia: 1 limit, 6 violations of any kind, 1 effluent exceedance, latest July 31, 2010, largest 14% over the limit.
- LC50 Static 48Hr Acute Pimephales promelas: 1 limit, 6 violations of any kind, 1 effluent exceedance, latest July 31, 2010, largest 14% over the limit.
- Chlorine, total residual: 1 limit, 1 violation of any kind, 1 effluent exceedance, latest May 31, 2023, largest 9% over the limit.
- Flow, in conduit or thru treatment plant: 4 limits, 12 violations of any kind.
- Nitrogen, total [as N]: 2 limits, 4 violations of any kind.
- Phosphorus, total [as P]: 2 limits, 4 violations of any kind.
- Overflows: 0 limits, 3 violations of any kind.
- Bypass valve: 0 limits, 2 violations of any kind.
- Bypass of Treatment Facility: 2 limits, 1 violation of any kind.
- E. coli: 2 limits.
- Release [Sewer], Dry Weather: 2 limits.
- Release [Sewer], Wet Weather: 2 limits.
- Oxygen, dissolved [DO]: 1 limit.
- September 17, 2026: Audit (S).
- July 29, 2026: Evaluation (S).
- July 28, 2026: Evaluation (S).
- August 21, 2025: Pretreatment - Failure to Enforce Against I/U (ST6).
- April 30, 2024: Monitoring Violations - Analysis not Conducted (ST6).
Tennessee holds 382 Publicly owned treatment works coverages of this permit type in EPA’s file; 227 were issued before TN0020672.
Coverages issued nearest TN0020672
- 2019-11-11: WESTMORELAND STP, Westmoreland: TN0055026, held by City of Westmoreland
- 2019-11-12: JELLICO UTILITIES AUTHORITY, Jellico: TN0022861, held by Jellico Electric and Water Systems
- 2019-11-12: JAMESTOWN STP, Jamestown: TN0062634, held by City of Jamestown
- 2019-11-27: SPRINGDALE ELEMENTARY SCHOOL, Tazewell: TN0055662, held by Claiborne County Department of Education
- 2019-11-27: NEWBERN STP, Newbern: TN0062111, held by Town of Newbern
- 2019-11-29: KNOXVILLE UTILITIES BOARD - EAST BRIDGE STP, Knoxville: TN0061743, held by Knoxville Utilities Board (KUB)
- 2019-11-29: BYRDSTOWN STP, Byrdstown: TN0062626, held by Town of Byrdstown
- 2019-12-01: PORTLAND STP, Portland: TN0021865, held by City of Portland
- 2019-12-01: HENNING WATER SYSTEMS/ WASTE WATER PUMP STATION, Henning: TN0025011, held by Town of Henning
- 2019-12-01: CHEROKEE COMPREHENSIVE HIGH SCHOOL, Rogersville: TN0054623, held by Hawkins County Board of Education
ROGERSVILLE STP among its neighbors
13 discharge permits are in the Cherokee Lake-Dodson Creek subwatershed (HUC 060101040204); TN0020672 is one. Its county: 79, 4 major; TN0020672 is major permit.
Other permits in the Cherokee Lake-Dodson Creek subwatershed (HUC 060101040204)
- 171 UTAH MOUNTAIN ROAD, Waynesville: NCG550298, minor, term to 2025-10-31
- EAST TN IRON & METAL, Bulls Gap: TNR052011, minor, term to 2025-06-30
- FORMER CHEROKEE #5, Rogersville: TNG830179, minor, term to 2013-02-14
- JOHN SEVIER COMBINED CYCLE PLANT, Rogersville: TNG670370, minor, term to 2010-12-14
- JOHN SEVIER DAM MAINTENANCE, Rogersville: TNR192403, minor, term to 2026-09-30
- JR STANTON/SUTHERLAND MARKET, Rogersville: TNG830194, minor, term to 2013-02-14
- PERSIA UTILITY DISTRICT - WATER TREATMENT PLANT, Rogersville: TN0075086, minor, term to 2025-08-31
- PIN 124383.00, PE # 37011-1237-94, Rogersville: TNR192254, minor, term to 2026-09-30
- SAM DONG, INC., Rogersville: TNR050262, minor, term to 2025-06-30
- SUMMERS-TAYLOR MATERIALS COMPANY DBA ROGERSVILLE CONCRETE PLANT, Rogersville: TNR161343, minor, term to 2026-09-30
What stands out
- Its term runs 5 years and 32 days, November 29, 2019 to December 31, 2024; the term ended 652 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
- Its newest dated event on file is an inspection on September 17, 2026, 27 days before EPA's file was loaded.
- In the 365 days to October 14, 2026, it was dated 3 inspections.
- EPA's file dates 5 events for it, from 2024 to 2026; the busiest year is 2026 with 3.
- 13 of its 23 pollutants on file have an effluent exceedance (57%); 19 are under a numeric limit; the largest exceedance is SSO, Dry Weather at 2,147,483,650% over its limit.
- It is one of 12,924 discharge permits on the register in Tennessee; 383 of them (3%) are in its program, Publicly owned treatment works, and it is a major discharger.
Identity
| Facility | ROGERSVILLE STP |
|---|---|
| Permittee | Town of Rogersville |
| NPDES ID | TN0020672 |
| Status | Administratively continued |
| Type | Individual permit |
| Class | Major |
| Facility type | Publicly owned treatment works |
| Program | Publicly owned treatment works |
| Issued | November 29, 2019 |
| Expires | December 31, 2024 |
| Agency | TDEC - DWR |
| Address | Rogersville, TN 37857 |
| Receiving water | Holston |
| Receiving water impaired | 303(D) Listed |
| Subwatershed | Cherokee Lake-Dodson Creek (HUC 060101040204) |
| Program components on file | POTW, Pretreatment |
| NAICS | 221320 – Sewage Treatment Facilities |
| SIC | 4952 – Sewerage Systems |
NPDES TN0020672: effluent limits and exceedances
ROGERSVILLE STP (NPDES TN0020672): 23 pollutants on file, 19 limited; 19 with a violation of any kind, 13 with an exceedance.
| Pollutant | Limits | Violations | Exceedances | Latest | Largest, as filed |
|---|---|---|---|---|---|
| Solids, total suspended | 7 | 80 | 80 | November 30, 2021 | 804% over the limit |
| BOD, 5-day, 20 deg. C | 7 | 31 | 31 | February 29, 2020 | 662% over the limit |
| Solids, suspended percent removal | 2 | 26 | 26 | February 29, 2020 | 120% over the limit |
| SSO, Dry Weather | 3 | 21 | 19 | March 31, 2026 | 2,147,483,650% over the limit |
| E. coli, MTEC-MF | 0 | 18 | 18 | February 28, 2019 | 697% over the limit |
| SSO, Wet Weather | 3 | 18 | 16 | January 31, 2026 | 2,147,483,650% over the limit |
| BOD, 5-day, percent removal | 2 | 7 | 7 | February 28, 2025 | 200% over the limit |
| Coliform, fecal MF, MFC broth, 44.5 C | 0 | 4 | 4 | March 31, 2009 | 375% over the limit |
| pH | 2 | 2 | 2 | March 31, 2014 | |
| Solids, settleable | 1 | 2 | 2 | May 31, 2014 | 900% over the limit |
| LC50 Static 48Hr Acute Ceriodaphnia dubia | 1 | 6 | 1 | July 31, 2010 | 14% over the limit |
| LC50 Static 48Hr Acute Pimephales promelas | 1 | 6 | 1 | July 31, 2010 | 14% over the limit |
| Chlorine, total residual | 1 | 1 | 1 | May 31, 2023 | 9% over the limit |
| Flow, in conduit or thru treatment plant | 4 | 12 | 0 | ||
| Nitrogen, total [as N] | 2 | 4 | 0 | ||
| Phosphorus, total [as P] | 2 | 4 | 0 | ||
| Overflows | 0 | 3 | 0 | ||
| Bypass valve | 0 | 2 | 0 | ||
| Bypass of Treatment Facility | 2 | 1 | 0 | ||
| E. coli | 2 | 0 | 0 | ||
| Release [Sewer], Dry Weather | 2 | 0 | 0 | ||
| Release [Sewer], Wet Weather | 2 | 0 | 0 | ||
| Oxygen, dissolved [DO] | 1 | 0 | 0 |
NPDES TN0020672: inspections, violations and enforcement
NPDES TN0020672: 2 single-event violations
| Date | What EPA recorded | Agency |
|---|---|---|
| August 21, 2025 | Pretreatment - Failure to Enforce Against I/U | ST6 |
| April 30, 2024 | Monitoring Violations - Analysis not Conducted | ST6 |
NPDES TN0020672: 3 inspections
| Date | What EPA recorded | Agency |
|---|---|---|
| September 17, 2026 | Audit | S |
| July 29, 2026 | Evaluation | S |
| July 28, 2026 | Evaluation | S |
NPDES TN0020672 (ROGERSVILLE STP): no formal enforcement action and informal enforcement action on file.
Watch NPDES TN0020672
NPDES TN0020672: one email when its EPA record changes — $99/month.
Permits near NPDES TN0020672
NPDES TN0020672: 23 pollutant rows, 5 dated events; ICIS-NPDES download, loaded October 14, 2026.