NPDES TX0003824 · Clean Water Act
STAFFORD FACILITY, Stafford, TX: NPDES TX0003824 discharge permit, effluent exceedances, inspections, penalties
STAFFORD FACILITY, Stafford, Texas: Individual permit TX0003824, held by TEXAS INSTRUMENTS INCORPORATED; Administratively continued; issued September 25, 2003, term to February 1, 2008; discharges to SEG NO 1007 SAN JACINTO RIVER BASIN.
1 of the 30 pollutants listed for NPDES TX0003824 have no violation or effluent exceedance.
- Whole effluent toxicity: 6 limits, 19 violations of any kind, 10 effluent exceedances, latest September 30, 2010, largest 99,999% over the limit.
- Oxygen demand, chem. [high level] [COD]: 9 limits, 27 violations of any kind, 9 effluent exceedances, latest July 31, 2011, largest 116% over the limit.
- Nitrogen, ammonia total [as N]: 2 limits, 8 violations of any kind, 4 effluent exceedances, latest January 31, 2007, largest 42% over the limit.
- Solids, total suspended: 4 limits, 11 violations of any kind, 3 effluent exceedances, latest October 31, 2010, largest 47% over the limit.
- Solids, total dissolved: 3 limits, 11 violations of any kind, 2 effluent exceedances, latest August 31, 2010, largest 69% over the limit.
- Chlorine, total residual: 2 limits, 4 violations of any kind, 2 effluent exceedances, latest October 31, 2003, largest 340% over the limit.
- pH: 14 limits, 31 violations of any kind, 1 effluent exceedance, latest July 31, 2005.
- Oil & Grease: 5 limits, 16 violations of any kind, 1 effluent exceedance, latest March 31, 2006, largest 105% over the limit.
- Flow, in conduit or thru treatment plant: 14 limits, 30 violations of any kind.
- pH range excursions, > 60 minutes: 2 limits, 17 violations of any kind.
- pH range excursions, monthly total accum: 2 limits, 17 violations of any kind.
- Fluoride, total [as F]: 4 limits, 8 violations of any kind.
- Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Ceriodaphnia dubia: 2 limits, 4 violations of any kind.
- NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia: 2 limits, 4 violations of any kind.
- NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia: 2 limits, 4 violations of any kind.
- Whole effluent toxicity - retest #1: 7 limits, 2 violations of any kind.
- LC50 Pass/Fail Static 24Hr Acute D. Pulex: 2 limits, 2 violations of any kind.
- LC50 Pass/Fail Static 24Hr Acute Pimephales promelas: 2 limits, 2 violations of any kind.
- Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Pimephales promelas: 2 limits, 2 violations of any kind.
- NOEC Lethal Static Renewal 7 Day Chronic Pimephales promelas: 2 limits, 2 violations of any kind.
- NOEC Sub-Lethal Static Renewal 7 Day Chronic Pimephales promelas: 2 limits, 2 violations of any kind.
- Copper, total [as Cu]: 1 limit, 2 violations of any kind.
- Nickel, total [as Ni]: 1 limit, 2 violations of any kind.
- Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia: 0 limits, 2 violations of any kind.
- Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Pinephales promelas: 0 limits, 2 violations of any kind.
- LOEC Lethal Survival Static Renewal 7 Day Chronic Ceriodaphnia dubia: 0 limits, 2 violations of any kind.
- LOEC Lethal Survival Static Renewal 7 Day Chronic Pimephales promelas: 0 limits, 2 violations of any kind.
- LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Ceriodaphnia dubia: 0 limits, 2 violations of any kind.
- LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Pimephales promelas: 0 limits, 2 violations of any kind.
- Whole effluent toxicity - retest #2: 7 limits.
STAFFORD FACILITY among its neighbors
229 discharge permits are in the Keegans Bayou-Brays Bayou subwatershed (HUC 120401040401); TX0003824 is one. Its county: 1,100, 41 major; TX0003824 is major permit.
Other permits in the Keegans Bayou-Brays Bayou subwatershed (HUC 120401040401)
- 11116 BELLAIRE BLVD, Houston: TXR1516PK, minor, term to 2028-03-04
- 33 ACRES AT FM 1464 AND BEECHNUT, Houston: TXR1520NC, minor, term to 2028-03-04
- ADDICKS PLANT, Houston: TXG110467, minor, term to 2011-11-07
- ADDICKS PLANT, City Of Houston: TXG111820, minor, term to 2016-11-07
- AI HOA PAD BUILDING A, Houston: TXR1597PL, minor, term to 2028-03-04
- ALIEF AG FACILITY, Houston: TXR1556VO, minor, term to 2028-03-04
- ALIEF CHILLER REPLACEMENTS - MULTI CAMPUS, Houston: TXR1516WP, minor, term to 2028-03-04
- ALIEF ISD LEROY CRUMP STADIUM, Houston: TXR1522WO, minor, term to 2028-03-04
- ALIEF ISD YWLS DRIVEWAY IMPROVEMENT, Houston: TXR1598XX, minor, term to 2028-03-04
- ALIEF SUPPORT FACILITY, Houston: TXR05BO39, minor, term to 2026-08-13
What stands out
- Its term runs 4 years and 129 days, September 25, 2003 to February 1, 2008; the term ended 6,830 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
- No dated event in the 365 days to October 14, 2026.
- 8 of its 30 pollutants on file have an effluent exceedance (27%); 24 are under a numeric limit; the largest exceedance is Whole effluent toxicity at 99,999% over its limit.
- It is one of 39,714 discharge permits on the register in Texas; the file names no program for it, and it is a major discharger.
Identity
| Facility | STAFFORD FACILITY |
|---|---|
| Permittee | TEXAS INSTRUMENTS INCORPORATED |
| NPDES ID | TX0003824 |
| Status | Administratively continued |
| Type | Individual permit |
| Class | Major |
| Facility type | Non-POTW |
| Issued | September 25, 2003 |
| Expires | February 1, 2008 |
| Address | Stafford, TX 77477 |
| Receiving water | SEG NO 1007 SAN JACINTO RIVER BASIN |
| Subwatershed | Keegans Bayou-Brays Bayou (HUC 120401040401) |
| SIC | 3674 – Semiconductors And Related Devices |
| Other EPA IDs (FRS) | RCRA handler TXD008073926; ICIS-AIR source TX0000004815700017 |
NPDES TX0003824: effluent limits and exceedances
STAFFORD FACILITY (NPDES TX0003824): 30 pollutants on file, 24 limited; 29 with a violation of any kind, 8 with an exceedance.
| Pollutant | Limits | Violations | Exceedances | Latest | Largest, as filed |
|---|---|---|---|---|---|
| Whole effluent toxicity | 6 | 19 | 10 | September 30, 2010 | 99,999% over the limit |
| Oxygen demand, chem. [high level] [COD] | 9 | 27 | 9 | July 31, 2011 | 116% over the limit |
| Nitrogen, ammonia total [as N] | 2 | 8 | 4 | January 31, 2007 | 42% over the limit |
| Solids, total suspended | 4 | 11 | 3 | October 31, 2010 | 47% over the limit |
| Solids, total dissolved | 3 | 11 | 2 | August 31, 2010 | 69% over the limit |
| Chlorine, total residual | 2 | 4 | 2 | October 31, 2003 | 340% over the limit |
| pH | 14 | 31 | 1 | July 31, 2005 | |
| Oil & Grease | 5 | 16 | 1 | March 31, 2006 | 105% over the limit |
| Flow, in conduit or thru treatment plant | 14 | 30 | 0 | ||
| pH range excursions, > 60 minutes | 2 | 17 | 0 | ||
| pH range excursions, monthly total accum | 2 | 17 | 0 | ||
| Fluoride, total [as F] | 4 | 8 | 0 | ||
| Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Ceriodaphnia dubia | 2 | 4 | 0 | ||
| NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | 2 | 4 | 0 | ||
| NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | 2 | 4 | 0 | ||
| Whole effluent toxicity - retest #1 | 7 | 2 | 0 | ||
| LC50 Pass/Fail Static 24Hr Acute D. Pulex | 2 | 2 | 0 | ||
| LC50 Pass/Fail Static 24Hr Acute Pimephales promelas | 2 | 2 | 0 | ||
| Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Pimephales promelas | 2 | 2 | 0 | ||
| NOEC Lethal Static Renewal 7 Day Chronic Pimephales promelas | 2 | 2 | 0 | ||
| NOEC Sub-Lethal Static Renewal 7 Day Chronic Pimephales promelas | 2 | 2 | 0 | ||
| Copper, total [as Cu] | 1 | 2 | 0 | ||
| Nickel, total [as Ni] | 1 | 2 | 0 | ||
| Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | 0 | 2 | 0 | ||
| Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Pinephales promelas | 0 | 2 | 0 | ||
| LOEC Lethal Survival Static Renewal 7 Day Chronic Ceriodaphnia dubia | 0 | 2 | 0 | ||
| LOEC Lethal Survival Static Renewal 7 Day Chronic Pimephales promelas | 0 | 2 | 0 | ||
| LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Ceriodaphnia dubia | 0 | 2 | 0 | ||
| LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Pimephales promelas | 0 | 2 | 0 | ||
| Whole effluent toxicity - retest #2 | 7 | 0 | 0 |
NPDES TX0003824: inspections, violations and enforcement
NPDES TX0003824 (STAFFORD FACILITY): no single-event violation, inspection, formal enforcement action and informal enforcement action on file.
Watch NPDES TX0003824
NPDES TX0003824: one email when its EPA record changes — $99/month.
Permits near NPDES TX0003824
NPDES TX0003824: 30 pollutant rows, 0 dated events; ICIS-NPDES download, loaded October 14, 2026.