Velarion Records
Free: one email when NPDES TX0008826 changes. Unsubscribe any time.

NPDES TX0008826 · Clean Water Act

BARNEY DAVIS ENERGY CENTER, Corpus Christi, TX: NPDES TX0008826 discharge permit, effluent exceedances, inspections, penalties

BARNEY DAVIS ENERGY CENTER, Corpus Christi, Texas: Individual permit TX0008826, held by BARNEY DAVIS LLC; Administratively continued; issued October 29, 2015, term to June 1, 2020; discharges to OSO CREEK;OSO BAY.

6 of the 26 pollutants listed for NPDES TX0008826 have no violation or effluent exceedance.

  • Solids, total suspended: 4 limits, 11 violations of any kind, 11 effluent exceedances, latest November 30, 2020, largest 7,100% over the limit.
  • pH: 6 limits, 1 violation of any kind, 1 effluent exceedance, latest March 31, 2008.
  • Flow, in conduit or thru treatment plant: 6 limits, 1 violation of any kind, 1 effluent exceedance, latest June 30, 2006, largest 39% over the limit.
  • Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Menidia menidia: 2 limits, 46 violations of any kind.
  • NOEC Lethal Static Renewal 7 Day Chronic Menidia menidia: 2 limits, 46 violations of any kind.
  • NOEC Sub-Lethal Static Renewal 7 Day Chronic Menidia menidia: 2 limits, 46 violations of any kind.
  • Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Menidia menidia: 2 limits, 46 violations of any kind.
  • Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Americamysis bahia (Mysidopsis bahia): 2 limits, 38 violations of any kind.
  • NOEC Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia): 2 limits, 38 violations of any kind.
  • NOEC Sub-Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia): 2 limits, 38 violations of any kind.
  • Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia): 2 limits, 38 violations of any kind.
  • LOEC Lethal Survival Static Renewal 7 Day Chronic Menidia menidia: 2 limits, 38 violations of any kind.
  • LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Menidia menidia: 2 limits, 38 violations of any kind.
  • LOEC Lethal Survival Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia): 2 limits, 30 violations of any kind.
  • LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Americamysis bahia (Mysidopsis bahia): 2 limits, 30 violations of any kind.
  • LC50 Pass/Fail Static 24Hr Acute Menidia menidia: 1 limit, 6 violations of any kind.
  • LC50 Pass/Fail Static 24Hr Acute Americamysis bahia (formerly Mysidopsis bahia): 1 limit, 4 violations of any kind.
  • Iron, total [as Fe]: 4 limits, 2 violations of any kind.
  • Chlorine, total residual: 2 limits, 2 violations of any kind.
  • Copper, total [as Cu]: 4 limits, 1 violation of any kind.
  • Oil & Grease: 4 limits.
  • Whole effluent toxicity - retest #1: 3 limits.
  • Whole effluent toxicity - retest #2: 3 limits.
  • Temperature, water deg. fahrenheit: 2 limits.
  • Lead, total [as Pb]: 2 limits.
  • Thallium, total [as Tl]: 2 limits.
  • September 1, 2026: No Further Action (State).
  • October 24, 2024: Permit Violations - Violation Specified in Comment (ST6).
  • February 27, 2019: Permit Violations - Violation Specified in Comment (ST6).
  • May 11, 2017: Permit Violations - Violation Specified in Comment (ST6).

BARNEY DAVIS ENERGY CENTER among its neighbors

43 discharge permits are in the Oso Creek-Frontal Oso Bay subwatershed (HUC 121102020106); TX0008826 is one. Its county: 317, 24 major; TX0008826 is major permit.

Other permits in the Oso Creek-Frontal Oso Bay subwatershed (HUC 121102020106)

What stands out

  • Its term runs 4 years and 216 days, October 29, 2015 to June 1, 2020; the term ended 2,326 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
  • Its newest dated event on file is an informal enforcement action on September 1, 2026, 43 days before EPA's file was loaded.
  • In the 365 days to October 14, 2026, it was dated 1 informal enforcement action.
  • EPA's file dates 4 events for it, from 2017 to 2026.
  • 3 of its 26 pollutants on file have an effluent exceedance (12%); 26 are under a numeric limit; the largest exceedance is Solids, total suspended at 7,100% over its limit.
  • It is one of 39,714 discharge permits on the register in Texas; the file names no program for it, and it is a major discharger.

Identity

FacilityBARNEY DAVIS ENERGY CENTER
PermitteeBARNEY DAVIS LLC
NPDES IDTX0008826
StatusAdministratively continued
TypeIndividual permit
ClassMajor
Facility typeNon-POTW
IssuedOctober 29, 2015
ExpiresJune 1, 2020
AddressCorpus Christi, TX 78418
Receiving waterOSO CREEK;OSO BAY
SubwatershedOso Creek-Frontal Oso Bay (HUC 121102020106)
SIC4911 – Electric Services
Other EPA IDs (FRS)RCRA handler TXD000761189; ICIS-AIR source TX0000004835500047

NPDES TX0008826: effluent limits and exceedances

BARNEY DAVIS ENERGY CENTER (NPDES TX0008826): 26 pollutants on file, 26 limited; 20 with a violation of any kind, 3 with an exceedance.

How exceedances are counted.

PollutantLimitsViolationsExceedancesLatestLargest, as filed
Solids, total suspended41111November 30, 20207,100% over the limit
pH611March 31, 2008
Flow, in conduit or thru treatment plant611June 30, 200639% over the limit
Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Menidia menidia2460
NOEC Lethal Static Renewal 7 Day Chronic Menidia menidia2460
NOEC Sub-Lethal Static Renewal 7 Day Chronic Menidia menidia2460
Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Menidia menidia2460
Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Americamysis bahia (Mysidopsis bahia)2380
NOEC Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)2380
NOEC Sub-Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)2380
Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)2380
LOEC Lethal Survival Static Renewal 7 Day Chronic Menidia menidia2380
LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Menidia menidia2380
LOEC Lethal Survival Static Renewal 7 Day Chronic Americamysis bahia (formerly Mysidopsis bahia)2300
LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Americamysis bahia (Mysidopsis bahia)2300
LC50 Pass/Fail Static 24Hr Acute Menidia menidia160
LC50 Pass/Fail Static 24Hr Acute Americamysis bahia (formerly Mysidopsis bahia)140
Iron, total [as Fe]420
Chlorine, total residual220
Copper, total [as Cu]410
Oil & Grease400
Whole effluent toxicity - retest #1300
Whole effluent toxicity - retest #2300
Temperature, water deg. fahrenheit200
Lead, total [as Pb]200
Thallium, total [as Tl]200

NPDES TX0008826: inspections, violations and enforcement

NPDES TX0008826: 3 single-event violations

DateWhat EPA recordedAgency
October 24, 2024Permit Violations - Violation Specified in CommentST6
February 27, 2019Permit Violations - Violation Specified in CommentST6
May 11, 2017Permit Violations - Violation Specified in CommentST6

NPDES TX0008826: 1 informal enforcement action

DateWhat EPA recordedAgency
September 1, 2026No Further ActionState

NPDES TX0008826 (BARNEY DAVIS ENERGY CENTER): no inspection and formal enforcement action on file.

Watch NPDES TX0008826

NPDES TX0008826: one email when its EPA record changes — $99/month.

Billing

Privacy

Permits near NPDES TX0008826

NPDES TX0008826: 26 pollutant rows, 4 dated events; ICIS-NPDES download, loaded October 14, 2026.