Velarion Records
Free: one email when NPDES TX0083178 changes. Unsubscribe any time.

NPDES TX0083178 · Clean Water Act

STRUCTURAL METALS, Seguin, TX: NPDES TX0083178 discharge permit, effluent exceedances, inspections, penalties

STRUCTURAL METALS, Seguin, Texas: Individual permit TX0083178, held by STRUCTURAL METALS, INC.; Administratively continued; issued July 16, 2015, term to February 1, 2020; discharges to GUADALUPE RIVER BELOW COMAL RIVER.

13 of the 28 pollutants listed for NPDES TX0083178 have no violation or effluent exceedance.

  • Oil & Grease: 2 limits, 42 violations of any kind, 17 effluent exceedances, latest May 31, 2010, largest 1,860% over the limit.
  • pH: 2 limits, 50 violations of any kind, 12 effluent exceedances, latest May 31, 2009.
  • Sulfate, total [as SO4]: 2 limits, 10 violations of any kind, 6 effluent exceedances, latest July 31, 2007, largest 67% over the limit.
  • Carbon, tot organic [TOC]: 0 limits, 22 violations of any kind, 5 effluent exceedances, latest May 31, 2010, largest 39% over the limit.
  • Chlorine, total residual: 2 limits, 2 violations of any kind, 2 effluent exceedances, latest October 31, 2005, largest 90% over the limit.
  • BOD, 5-day, 20 deg. C: 2 limits, 5 violations of any kind, 1 effluent exceedance, latest November 30, 2003, largest 57% over the limit.
  • Temperature, water deg. fahrenheit: 1 limit, 3 violations of any kind, 1 effluent exceedance, latest May 31, 2005, largest 8,164% over the limit.
  • Oil and grease visual: 0 limits, 7 violations of any kind.
  • Solids, total suspended: 2 limits, 4 violations of any kind.
  • Chloride [as Cl]: 2 limits, 4 violations of any kind.
  • Chromium, total [as Cr]: 2 limits, 4 violations of any kind.
  • Copper, total [as Cu]: 2 limits, 4 violations of any kind.
  • Lead, total [as Pb]: 2 limits, 4 violations of any kind.
  • Zinc, total [as Zn]: 2 limits, 4 violations of any kind.
  • Cadmium, total [as Cd]: 1 limit, 3 violations of any kind.
  • E. coli: 4 limits.
  • Whole effluent toxicity - retest #1: 3 limits.
  • Whole effluent toxicity - retest #2: 3 limits.
  • Flow, in conduit or thru treatment plant: 2 limits.
  • Low Flow Pass/Fail Static Renewal 48Hr Acute Daphnia pulex: 2 limits.
  • LF Pass/Fail Static Renewal 48Hr Acute Pimephales promelas: 2 limits.
  • NOAEC Lethal Statis Renewal 48 Hr Acute Daphnia pulex: 2 limits.
  • NOAEC Lethal Static Renewal 48Hr acute Pimephales promelas: 2 limits.
  • LOAEC Lethal Static Renewal 48HR Acute Daphnia pulex: 2 limits.
  • LOAEC Lethal Survival Static Renewal 48Hr Acute Pimephales promelas: 2 limits.
  • Oxygen, dissolved [DO]: 1 limit.
  • LC50 Pass/Fail Static 24Hr Acute D. Pulex: 1 limit.
  • LC50 Pass/Fail Static 24Hr Acute Pimephales promelas: 1 limit.

STRUCTURAL METALS among its neighbors

55 discharge permits are in the Youngs Creek-Guadalupe River subwatershed (HUC 121002020108); TX0083178 is one. Its county: 328, 3 major; TX0083178 is major permit.

Other permits in the Youngs Creek-Guadalupe River subwatershed (HUC 121002020108)

What stands out

  • Its term runs 4 years and 200 days, July 16, 2015 to February 1, 2020; the term ended 2,447 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
  • No dated event in the 365 days to October 14, 2026.
  • 7 of its 28 pollutants on file have an effluent exceedance (25%); 26 are under a numeric limit; the largest exceedance is Temperature, water deg. fahrenheit at 8,164% over its limit.
  • It is one of 39,714 discharge permits on the register in Texas; the file names no program for it, and it is a major discharger.

Identity

FacilitySTRUCTURAL METALS
PermitteeSTRUCTURAL METALS, INC.
NPDES IDTX0083178
StatusAdministratively continued
TypeIndividual permit
ClassMajor
Facility typeNon-POTW
IssuedJuly 16, 2015
ExpiresFebruary 1, 2020
AddressSeguin, TX 78155
Receiving waterGUADALUPE RIVER BELOW COMAL RIVER
SubwatershedYoungs Creek-Guadalupe River (HUC 121002020108)
SIC3312 – Blast Furnaces And Steel Mills
Other EPA IDs (FRS)RCRA handler TXD008119414; ICIS-AIR source TX0000004818700001

NPDES TX0083178: effluent limits and exceedances

STRUCTURAL METALS (NPDES TX0083178): 28 pollutants on file, 26 limited; 15 with a violation of any kind, 7 with an exceedance.

How exceedances are counted.

PollutantLimitsViolationsExceedancesLatestLargest, as filed
Oil & Grease24217May 31, 20101,860% over the limit
pH25012May 31, 2009
Sulfate, total [as SO4]2106July 31, 200767% over the limit
Carbon, tot organic [TOC]0225May 31, 201039% over the limit
Chlorine, total residual222October 31, 200590% over the limit
BOD, 5-day, 20 deg. C251November 30, 200357% over the limit
Temperature, water deg. fahrenheit131May 31, 20058,164% over the limit
Oil and grease visual070
Solids, total suspended240
Chloride [as Cl]240
Chromium, total [as Cr]240
Copper, total [as Cu]240
Lead, total [as Pb]240
Zinc, total [as Zn]240
Cadmium, total [as Cd]130
E. coli400
Whole effluent toxicity - retest #1300
Whole effluent toxicity - retest #2300
Flow, in conduit or thru treatment plant200
Low Flow Pass/Fail Static Renewal 48Hr Acute Daphnia pulex200
LF Pass/Fail Static Renewal 48Hr Acute Pimephales promelas200
NOAEC Lethal Statis Renewal 48 Hr Acute Daphnia pulex200
NOAEC Lethal Static Renewal 48Hr acute Pimephales promelas200
LOAEC Lethal Static Renewal 48HR Acute Daphnia pulex200
LOAEC Lethal Survival Static Renewal 48Hr Acute Pimephales promelas200
Oxygen, dissolved [DO]100
LC50 Pass/Fail Static 24Hr Acute D. Pulex100
LC50 Pass/Fail Static 24Hr Acute Pimephales promelas100

NPDES TX0083178: inspections, violations and enforcement

NPDES TX0083178 (STRUCTURAL METALS): no single-event violation, inspection, formal enforcement action and informal enforcement action on file.

Watch NPDES TX0083178

NPDES TX0083178: one email when its EPA record changes — $99/month.

Billing

Privacy

Permits near NPDES TX0083178

NPDES TX0083178: 28 pollutant rows, 0 dated events; ICIS-NPDES download, loaded October 14, 2026.