NPDES TX0103080 · Clean Water Act
GREENVILLE STEAM PLANT, Greenville, TX: NPDES TX0103080 discharge permit, effluent exceedances, inspections, penalties
GREENVILLE STEAM PLANT, Greenville, Texas: Individual permit TX0103080, held by GREENVILLE ELECTRIC UTILITY SYSTEM; Administratively continued; issued April 26, 2016, term to March 1, 2021; discharges to GREENVILLE RES 6 & 4, COWLEECH FORK SABINE RV.
- Aluminum, total [as Al]: 0 limits, 37 violations of any kind, 37 effluent exceedances, latest April 30, 2006, largest 563% over the limit.
- Chlorine, total residual: 2 limits, 24 violations of any kind, 6 effluent exceedances, latest August 31, 2020, largest 305% over the limit.
- pH: 2 limits, 12 violations of any kind, 2 effluent exceedances, latest May 31, 2016.
- Flow, in conduit or thru treatment plant: 2 limits, 13 violations of any kind, 1 effluent exceedance, latest October 31, 2004, largest 32,460% over the limit.
- Lead, total [as Pb]: 4 limits, 20 violations of any kind.
- Solids, total dissolved: 2 limits, 12 violations of any kind.
- Temperature, water deg. fahrenheit: 1 limit, 10 violations of any kind.
- Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Ceriodaphnia dubia: 0 limits, 2 violations of any kind.
- Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Pimephales promelas: 0 limits, 2 violations of any kind.
- NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia: 0 limits, 2 violations of any kind.
- NOEC Lethal Static Renewal 7 Day Chronic Pimephales promelas: 0 limits, 2 violations of any kind.
- NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia: 0 limits, 2 violations of any kind.
- NOEC Sub-Lethal Static Renewal 7 Day Chronic Pimephales promelas: 0 limits, 2 violations of any kind.
- Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia: 0 limits, 2 violations of any kind.
- Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Pinephales promelas: 0 limits, 2 violations of any kind.
- LOEC Lethal Survival Static Renewal 7 Day Chronic Ceriodaphnia dubia: 0 limits, 2 violations of any kind.
- LOEC Lethal Survival Static Renewal 7 Day Chronic Pimephales promelas: 0 limits, 2 violations of any kind.
- LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Ceriodaphnia dubia: 0 limits, 2 violations of any kind.
- LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Pimephales promelas: 0 limits, 2 violations of any kind.
GREENVILLE STEAM PLANT among its neighbors
5 discharge permits are in the Horse Creek-Cowleech Fork Sabine River subwatershed (HUC 120100010102); TX0103080 is one. Its county: 194, 4 major; TX0103080 is major permit.
Other permits in the Horse Creek-Cowleech Fork Sabine River subwatershed (HUC 120100010102)
- CITY OF GREENVILLE RAW WATER MAIN PARALLEL PIPELINE, Greenville: TXR1517QA, minor, term to 2028-03-04
- DELANO ESTATES, Greenville: TXR1521NN, minor, term to 2028-03-04
- GREENVILLE METAL RECYCLERS, Greenville: TXR05EZ34, minor, term to 2026-08-13
- GREENVILLE STORAGE, Greenville: TXR1581XR, minor, term to 2028-03-04
What stands out
- Its term runs 4 years and 309 days, April 26, 2016 to March 1, 2021; the term ended 2,053 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
- No dated event in the 365 days to October 14, 2026.
- 4 of its 19 pollutants on file have an effluent exceedance (21%); 6 are under a numeric limit; the largest exceedance is Flow, in conduit or thru treatment plant at 32,460% over its limit.
- It is one of 39,714 discharge permits on the register in Texas; the file names no program for it, and it is a major discharger.
Identity
| Facility | GREENVILLE STEAM PLANT |
|---|---|
| Permittee | GREENVILLE ELECTRIC UTILITY SYSTEM |
| NPDES ID | TX0103080 |
| Status | Administratively continued |
| Type | Individual permit |
| Class | Major |
| Facility type | Non-POTW |
| Issued | April 26, 2016 |
| Expires | March 1, 2021 |
| Address | Greenville, TX 75402 |
| Receiving water | GREENVILLE RES 6 & 4, COWLEECH FORK SABINE RV |
| Subwatershed | Horse Creek-Cowleech Fork Sabine River (HUC 120100010102) |
| SIC | 4911 – Electric Services |
| Other EPA IDs (FRS) | RCRA handler TXR000087413; ICIS-AIR source TX0000004823100009 |
NPDES TX0103080: effluent limits and exceedances
GREENVILLE STEAM PLANT (NPDES TX0103080): 19 pollutants on file, 6 limited; 19 with a violation of any kind, 4 with an exceedance.
| Pollutant | Limits | Violations | Exceedances | Latest | Largest, as filed |
|---|---|---|---|---|---|
| Aluminum, total [as Al] | 0 | 37 | 37 | April 30, 2006 | 563% over the limit |
| Chlorine, total residual | 2 | 24 | 6 | August 31, 2020 | 305% over the limit |
| pH | 2 | 12 | 2 | May 31, 2016 | |
| Flow, in conduit or thru treatment plant | 2 | 13 | 1 | October 31, 2004 | 32,460% over the limit |
| Lead, total [as Pb] | 4 | 20 | 0 | ||
| Solids, total dissolved | 2 | 12 | 0 | ||
| Temperature, water deg. fahrenheit | 1 | 10 | 0 | ||
| Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Ceriodaphnia dubia | 0 | 2 | 0 | ||
| Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Pimephales promelas | 0 | 2 | 0 | ||
| NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | 0 | 2 | 0 | ||
| NOEC Lethal Static Renewal 7 Day Chronic Pimephales promelas | 0 | 2 | 0 | ||
| NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | 0 | 2 | 0 | ||
| NOEC Sub-Lethal Static Renewal 7 Day Chronic Pimephales promelas | 0 | 2 | 0 | ||
| Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | 0 | 2 | 0 | ||
| Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Pinephales promelas | 0 | 2 | 0 | ||
| LOEC Lethal Survival Static Renewal 7 Day Chronic Ceriodaphnia dubia | 0 | 2 | 0 | ||
| LOEC Lethal Survival Static Renewal 7 Day Chronic Pimephales promelas | 0 | 2 | 0 | ||
| LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Ceriodaphnia dubia | 0 | 2 | 0 | ||
| LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Pimephales promelas | 0 | 2 | 0 |
NPDES TX0103080: inspections, violations and enforcement
NPDES TX0103080 (GREENVILLE STEAM PLANT): no single-event violation, inspection, formal enforcement action and informal enforcement action on file.
Watch NPDES TX0103080
NPDES TX0103080: one email when its EPA record changes — $99/month.
Permits near NPDES TX0103080
NPDES TX0103080: 19 pollutant rows, 0 dated events; ICIS-NPDES download, loaded October 14, 2026.