NPDES TX0123935 · Clean Water Act
FREESTONE POWER GENERATION PLANT, Fairfield, TX: NPDES TX0123935 discharge permit, effluent exceedances, inspections, penalties
FREESTONE POWER GENERATION PLANT, Fairfield, Texas: Individual permit TX0123935, held by FREESTONE POWER GENERATION LLC AND CALPINE OPERATING SERVICES COMPANY INC; Administratively continued; issued May 2, 2017, term to February 1, 2022; discharges to TRINITY RIVER ABOVE LAKE LIVINGSTON.
2 of the 18 pollutants listed for NPDES TX0123935 have no violation or effluent exceedance.
- Solids, total suspended: 2 limits, 30 violations of any kind, 25 effluent exceedances, latest September 30, 2022, largest 130% over the limit.
- Chlorine, free available: 2 limits, 6 violations of any kind, 2 effluent exceedances, latest January 31, 2006, largest 300% over the limit.
- Oil & Grease: 2 limits, 5 violations of any kind, 1 effluent exceedance, latest December 31, 2018, largest 33% over the limit.
- Flow, in conduit or thru treatment plant: 2 limits, 5 violations of any kind, 1 effluent exceedance, latest August 31, 2015, largest 5% over the limit.
- LOAEC Lethal Survival Static Renewal 48Hr Acute Pimephales promelas: 2 limits, 20 violations of any kind.
- LOAEC Lethal Static Renewal 48HR Acute Daphnia pulex: 2 limits, 19 violations of any kind.
- Low Flow Pass/Fail Static Renewal 48Hr Acute Daphnia pulex: 2 limits, 16 violations of any kind.
- LF Pass/Fail Static Renewal 48Hr Acute Pimephales promelas: 2 limits, 16 violations of any kind.
- NOAEC Lethal Statis Renewal 48 Hr Acute Daphnia pulex: 2 limits, 16 violations of any kind.
- NOAEC Lethal Static Renewal 48Hr acute Pimephales promelas: 2 limits, 16 violations of any kind.
- E. coli: 1 limit, 13 violations of any kind.
- Whole effluent toxicity - retest #1: 3 limits, 8 violations of any kind.
- Whole effluent toxicity - retest #2: 3 limits, 8 violations of any kind.
- pH: 2 limits, 4 violations of any kind.
- LC50 Pass/Fail Static 24Hr Acute D. Pulex: 1 limit, 2 violations of any kind.
- LC50 Pass/Fail Static 24Hr Acute Pimephales promelas: 1 limit, 2 violations of any kind.
- Chromium, total [as Cr]: 2 limits.
- Zinc, total [as Zn]: 2 limits.
- January 3, 2019: Permit Violations - Violation Specified in Comment (ST6).
- March 1, 2017: Permit Violations - Violation Specified in Comment (ST6).
FREESTONE POWER GENERATION PLANT among its neighbors
5 discharge permits are in the Saline Branch-Trinity River subwatershed (HUC 120302010301); TX0123935 is one. Its county: 35, 3 major; TX0123935 is major permit.
Other permits in the Saline Branch-Trinity River subwatershed (HUC 120302010301)
- ACME BRICK - THORNTON PIT, Athens: TXR05HB96, minor, term to 2026-08-13
- CAYUGA ISD, Cayuga: TX0111520, minor, term to 2022-02-01
- CAYUGA ISD SPORTS FACILITY IMPROVEMENTS, Tennessee Colony: TXR1505TB, minor, term to 2028-03-04
- CAYUGA SAND PLANT, Cayuga: TXR05FJ32, minor, term to 2026-08-13
What stands out
- Its term runs 4 years and 275 days, May 2, 2017 to February 1, 2022; the term ended 1,716 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
- Its newest dated event on file is a single-event violation on January 3, 2019, 2,841 days before EPA's file was loaded.
- No dated event in the 365 days to October 14, 2026.
- EPA's file dates 2 events for it, from 2017 to 2019.
- 4 of its 18 pollutants on file have an effluent exceedance (22%); 18 are under a numeric limit; the largest exceedance is Chlorine, free available at 300% over its limit.
- It is one of 39,714 discharge permits on the register in Texas; the file names no program for it, and it is a major discharger.
Identity
| Facility | FREESTONE POWER GENERATION PLANT |
|---|---|
| Permittee | FREESTONE POWER GENERATION LLC AND CALPINE OPERATING SERVICES COMPANY INC |
| NPDES ID | TX0123935 |
| Status | Administratively continued |
| Type | Individual permit |
| Class | Major |
| Facility type | Non-POTW |
| Issued | May 2, 2017 |
| Expires | February 1, 2022 |
| Address | Fairfield, TX 75840 |
| Receiving water | TRINITY RIVER ABOVE LAKE LIVINGSTON |
| Receiving water impaired | 303(D) Listed |
| Subwatershed | Saline Branch-Trinity River (HUC 120302010301) |
| SIC | 4911 – Electric Services |
NPDES TX0123935: effluent limits and exceedances
FREESTONE POWER GENERATION PLANT (NPDES TX0123935): 18 pollutants on file, 18 limited; 16 with a violation of any kind, 4 with an exceedance.
| Pollutant | Limits | Violations | Exceedances | Latest | Largest, as filed |
|---|---|---|---|---|---|
| Solids, total suspended | 2 | 30 | 25 | September 30, 2022 | 130% over the limit |
| Chlorine, free available | 2 | 6 | 2 | January 31, 2006 | 300% over the limit |
| Oil & Grease | 2 | 5 | 1 | December 31, 2018 | 33% over the limit |
| Flow, in conduit or thru treatment plant | 2 | 5 | 1 | August 31, 2015 | 5% over the limit |
| LOAEC Lethal Survival Static Renewal 48Hr Acute Pimephales promelas | 2 | 20 | 0 | ||
| LOAEC Lethal Static Renewal 48HR Acute Daphnia pulex | 2 | 19 | 0 | ||
| Low Flow Pass/Fail Static Renewal 48Hr Acute Daphnia pulex | 2 | 16 | 0 | ||
| LF Pass/Fail Static Renewal 48Hr Acute Pimephales promelas | 2 | 16 | 0 | ||
| NOAEC Lethal Statis Renewal 48 Hr Acute Daphnia pulex | 2 | 16 | 0 | ||
| NOAEC Lethal Static Renewal 48Hr acute Pimephales promelas | 2 | 16 | 0 | ||
| E. coli | 1 | 13 | 0 | ||
| Whole effluent toxicity - retest #1 | 3 | 8 | 0 | ||
| Whole effluent toxicity - retest #2 | 3 | 8 | 0 | ||
| pH | 2 | 4 | 0 | ||
| LC50 Pass/Fail Static 24Hr Acute D. Pulex | 1 | 2 | 0 | ||
| LC50 Pass/Fail Static 24Hr Acute Pimephales promelas | 1 | 2 | 0 | ||
| Chromium, total [as Cr] | 2 | 0 | 0 | ||
| Zinc, total [as Zn] | 2 | 0 | 0 |
NPDES TX0123935: inspections, violations and enforcement
NPDES TX0123935: 2 single-event violations
| Date | What EPA recorded | Agency |
|---|---|---|
| January 3, 2019 | Permit Violations - Violation Specified in Comment | ST6 |
| March 1, 2017 | Permit Violations - Violation Specified in Comment | ST6 |
NPDES TX0123935 (FREESTONE POWER GENERATION PLANT): no inspection, formal enforcement action and informal enforcement action on file.
Watch NPDES TX0123935
NPDES TX0123935: one email when its EPA record changes — $99/month.
Permits near NPDES TX0123935
NPDES TX0123935: 18 pollutant rows, 2 dated events; ICIS-NPDES download, loaded October 14, 2026.