Velarion Records
Free: one email when NPDES TXG110197 changes. Unsubscribe any time.

NPDES TXG110197 · Clean Water Act

CONTRACTORS SUPPLIES LONGVIEW PLANT, Longview, TX: NPDES TXG110197 discharge permit, effluent exceedances, inspections, penalties

CONTRACTORS SUPPLIES LONGVIEW PLANT, Longview, Texas: General permit coverage TXG110197, held by CONTRACTOR'S SUPPLIES, INC.; Administratively continued; issued January 20, 2017, term to November 7, 2021; discharges to GRACE CREEK.

2 of the 20 pollutants listed for NPDES TXG110197 have no violation or effluent exceedance.

  • Solids, total suspended: 2 limits, 105 violations of any kind, 24 effluent exceedances, latest February 28, 2023, largest 685% over the limit.
  • Mercury, total [as Hg]: 2 limits, 28 violations of any kind, 4 effluent exceedances, latest February 28, 2003, largest 3,900% over the limit.
  • pH: 4 limits, 177 violations of any kind, 2 effluent exceedances, latest May 31, 2001.
  • Oil & Grease: 2 limits, 95 violations of any kind, 2 effluent exceedances, latest February 28, 2010, largest 3,233% over the limit.
  • Selenium, total [as Se]: 2 limits, 28 violations of any kind, 2 effluent exceedances, latest February 28, 2001, largest 9,900% over the limit.
  • Nickel, total [as Ni]: 2 limits, 24 violations of any kind, 2 effluent exceedances, latest February 28, 2001, largest 1,180% over the limit.
  • Zinc, total [as Zn]: 2 limits, 24 violations of any kind, 2 effluent exceedances, latest February 28, 2001, largest 2,500% over the limit.
  • Flow, in conduit or thru treatment plant: 2 limits, 112 violations of any kind.
  • Manganese, total [as Mn]: 2 limits, 26 violations of any kind.
  • Lead, total [as Pb]: 2 limits, 24 violations of any kind.
  • Cadmium, total [as Cd]: 2 limits, 23 violations of any kind.
  • Arsenic, total [as As]: 2 limits, 22 violations of any kind.
  • Barium, total [as Ba]: 2 limits, 22 violations of any kind.
  • Chromium, total [as Cr]: 2 limits, 22 violations of any kind.
  • Copper, total [as Cu]: 2 limits, 22 violations of any kind.
  • Silver, total [as Ag]: 2 limits, 20 violations of any kind.
  • LC50 Pass/Fail Static 24Hr Acute D. Pulex: 2 limits, 13 violations of any kind.
  • LC50 Pass/Fail Static 24Hr Acute Pimephales promelas: 2 limits, 13 violations of any kind.
  • Whole effluent toxicity - retest #1: 2 limits.
  • Whole effluent toxicity - retest #2: 2 limits.

Other permits held by CONTRACTOR'S SUPPLIES, INC.

CONTRACTORS SUPPLIES LONGVIEW PLANT among its neighbors

37 discharge permits are in the Grace Creek subwatershed (HUC 120100020505); TXG110197 is one. Its county: 124, 6 major; TXG110197 is minor permit.

Other permits in the Grace Creek subwatershed (HUC 120100020505)

What stands out

  • Its term runs 4 years and 291 days, January 20, 2017 to November 7, 2021; the term ended 1,802 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
  • No dated event in the 365 days to October 14, 2026.
  • 7 of its 20 pollutants on file have an effluent exceedance (35%); 20 are under a numeric limit; the largest exceedance is Selenium, total [as Se] at 9,900% over its limit.
  • It is one of 39,714 discharge permits on the register in Texas; the file names no program for it, and it is a minor discharger.

Identity

FacilityCONTRACTORS SUPPLIES LONGVIEW PLANT
PermitteeCONTRACTOR'S SUPPLIES, INC.
NPDES IDTXG110197
StatusAdministratively continued
TypeGeneral permit coverage
ClassMinor
Facility typeNon-POTW
IssuedJanuary 20, 2017
ExpiresNovember 7, 2021
AddressLongview, TX 75602
Receiving waterGRACE CREEK
SubwatershedGrace Creek (HUC 120100020505)
SIC3273 – Ready-Mixed Concrete

NPDES TXG110197: effluent limits and exceedances

CONTRACTORS SUPPLIES LONGVIEW PLANT (NPDES TXG110197): 20 pollutants on file, 20 limited; 18 with a violation of any kind, 7 with an exceedance.

How exceedances are counted.

PollutantLimitsViolationsExceedancesLatestLargest, as filed
Solids, total suspended210524February 28, 2023685% over the limit
Mercury, total [as Hg]2284February 28, 20033,900% over the limit
pH41772May 31, 2001
Oil & Grease2952February 28, 20103,233% over the limit
Selenium, total [as Se]2282February 28, 20019,900% over the limit
Nickel, total [as Ni]2242February 28, 20011,180% over the limit
Zinc, total [as Zn]2242February 28, 20012,500% over the limit
Flow, in conduit or thru treatment plant21120
Manganese, total [as Mn]2260
Lead, total [as Pb]2240
Cadmium, total [as Cd]2230
Arsenic, total [as As]2220
Barium, total [as Ba]2220
Chromium, total [as Cr]2220
Copper, total [as Cu]2220
Silver, total [as Ag]2200
LC50 Pass/Fail Static 24Hr Acute D. Pulex2130
LC50 Pass/Fail Static 24Hr Acute Pimephales promelas2130
Whole effluent toxicity - retest #1200
Whole effluent toxicity - retest #2200

NPDES TXG110197: inspections, violations and enforcement

NPDES TXG110197 (CONTRACTORS SUPPLIES LONGVIEW PLANT): no single-event violation, inspection, formal enforcement action and informal enforcement action on file.

Watch NPDES TXG110197

NPDES TXG110197: one email when its EPA record changes — $99/month.

Billing

Privacy

Permits near NPDES TXG110197

NPDES TXG110197: 20 pollutant rows, 0 dated events; ICIS-NPDES download, loaded October 14, 2026.