NPDES TXG112926 · Clean Water Act
GUNTER FACILITY, Gunter, TX: NPDES TXG112926 discharge permit, effluent exceedances, inspections, penalties
GUNTER FACILITY, Gunter, Texas: General permit coverage TXG112926, held by AmeriTex Pipe & Products, LLC; Administratively continued; issued September 23, 2021, term to November 6, 2021.
5 of the 20 pollutants listed for NPDES TXG112926 have no violation or effluent exceedance.
- Solids, total suspended: 1 limit, 1 violation of any kind, 1 effluent exceedance, latest October 31, 2023, largest 303% over the limit.
- Arsenic, total [as As]: 1 limit, 1 violation of any kind.
- Barium, total [as Ba]: 1 limit, 1 violation of any kind.
- Cadmium, total [as Cd]: 1 limit, 1 violation of any kind.
- Chromium, total [as Cr]: 1 limit, 1 violation of any kind.
- Copper, total [as Cu]: 1 limit, 1 violation of any kind.
- Lead, total [as Pb]: 1 limit, 1 violation of any kind.
- Manganese, total [as Mn]: 1 limit, 1 violation of any kind.
- Nickel, total [as Ni]: 1 limit, 1 violation of any kind.
- Silver, total [as Ag]: 1 limit, 1 violation of any kind.
- Zinc, total [as Zn]: 1 limit, 1 violation of any kind.
- Selenium, total [as Se]: 1 limit, 1 violation of any kind.
- Mercury, total [as Hg]: 1 limit, 1 violation of any kind.
- LC50 Pass/Fail Static 24Hr Acute D. Pulex: 1 limit, 1 violation of any kind.
- LC50 Pass/Fail Static 24Hr Acute Pimephales promelas: 1 limit, 1 violation of any kind.
- pH: 2 limits.
- Oil & Grease: 1 limit.
- Whole effluent toxicity - retest #1: 1 limit.
- Whole effluent toxicity - retest #2: 1 limit.
- Flow, in conduit or thru treatment plant: 1 limit.
Other permits held by AmeriTex Pipe & Products, LLC
- SEGUIN PRECAST FACILITY, Seguin: TXG112386, issued 2018-09-10
- CONROE PRECAST FACILITY, Conroe: TXG112449, issued 2019-02-14
- GUNTER FACILITY, Gunter: TXR05FX96, issued 2023-01-06
- CONROE CONCRETE CRUSHER, Conroe: TXR05GL49, issued 2024-06-20
- AMERITEX HDPE, Conroe: TXR1564QZ, issued 2024-05-29
GUNTER FACILITY among its neighbors
16 discharge permits are in the Bear Creek-Buck Creek subwatershed (HUC 120301030206); TXG112926 is one.
Other permits in the Bear Creek-Buck Creek subwatershed (HUC 120301030206)
- BUCK CREEK WWTP, Gunter: TX0143201, minor, term to 2029-10-24
- EASTWELL FARMS PHASE 1, Tioga: TXR1537VG, minor, term to 2028-03-04
- EASTWELL FARMS PHASE 1, Tioga: TXR1589VK, minor, term to 2028-03-04
- EASTWELL FARMS PHASE 1 MASS GRADING, Tioga: TXR1522QN, minor, term to 2028-03-04
- GUNTER 5 CBP, Gunter: TXG113138, minor, term to 2026-11-06
- GUNTER CBP, Gunter: TXG113812, minor, term to 2026-11-06
- GUNTER CBP 1, Gunter: TXG112894, minor, term to 2021-11-06
- GUNTER CBP 1, Gunter: TXG113169, minor, term to 2026-11-06
- GUNTER CBP FACILITY, Gunter: TXG113945, minor, term to 2026-11-06
- GUNTER FACILITY, Gunter: TXR05FX96, minor, term to 2026-08-13
What stands out
- Its term runs 44 days, September 23, 2021 to November 6, 2021; the term ended 1,803 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
- No dated event in the 365 days to October 14, 2026.
- 1 of its 20 pollutants on file has an effluent exceedance (5%); 20 are under a numeric limit; the largest exceedance is Solids, total suspended at 303% over its limit.
- It is one of 39,714 discharge permits on the register in Texas; the file names no program for it, and it is a minor discharger.
Identity
| Facility | GUNTER FACILITY |
|---|---|
| Permittee | AmeriTex Pipe & Products, LLC |
| NPDES ID | TXG112926 |
| Status | Administratively continued |
| Type | General permit coverage |
| Class | Minor |
| Facility type | Non-POTW |
| Issued | September 23, 2021 |
| Expires | November 6, 2021 |
| Address | Gunter, TX 75058 |
| Subwatershed | Bear Creek-Buck Creek (HUC 120301030206) |
| SIC | 3272 – Concrete Products |
NPDES TXG112926: effluent limits and exceedances
GUNTER FACILITY (NPDES TXG112926): 20 pollutants on file, 20 limited; 15 with a violation of any kind, 1 with an exceedance.
| Pollutant | Limits | Violations | Exceedances | Latest | Largest, as filed |
|---|---|---|---|---|---|
| Solids, total suspended | 1 | 1 | 1 | October 31, 2023 | 303% over the limit |
| Arsenic, total [as As] | 1 | 1 | 0 | ||
| Barium, total [as Ba] | 1 | 1 | 0 | ||
| Cadmium, total [as Cd] | 1 | 1 | 0 | ||
| Chromium, total [as Cr] | 1 | 1 | 0 | ||
| Copper, total [as Cu] | 1 | 1 | 0 | ||
| Lead, total [as Pb] | 1 | 1 | 0 | ||
| Manganese, total [as Mn] | 1 | 1 | 0 | ||
| Nickel, total [as Ni] | 1 | 1 | 0 | ||
| Silver, total [as Ag] | 1 | 1 | 0 | ||
| Zinc, total [as Zn] | 1 | 1 | 0 | ||
| Selenium, total [as Se] | 1 | 1 | 0 | ||
| Mercury, total [as Hg] | 1 | 1 | 0 | ||
| LC50 Pass/Fail Static 24Hr Acute D. Pulex | 1 | 1 | 0 | ||
| LC50 Pass/Fail Static 24Hr Acute Pimephales promelas | 1 | 1 | 0 | ||
| pH | 2 | 0 | 0 | ||
| Oil & Grease | 1 | 0 | 0 | ||
| Whole effluent toxicity - retest #1 | 1 | 0 | 0 | ||
| Whole effluent toxicity - retest #2 | 1 | 0 | 0 | ||
| Flow, in conduit or thru treatment plant | 1 | 0 | 0 |
NPDES TXG112926: inspections, violations and enforcement
NPDES TXG112926 (GUNTER FACILITY): no single-event violation, inspection, formal enforcement action and informal enforcement action on file.
Watch NPDES TXG112926
NPDES TXG112926: one email when its EPA record changes — $99/month.
Permits near NPDES TXG112926
NPDES TXG112926: 20 pollutant rows, 0 dated events; ICIS-NPDES download, loaded October 14, 2026.