RES DBA STEEL DYNAMICS ROANOKE BAR DIVISION, Roanoke, VA: NPDES VA0001589 discharge permit, effluent exceedances, inspections, penalties

RES DBA STEEL DYNAMICS ROANOKE BAR DIVISION, Roanoke, Virginia: Individual permit VA0001589, held by Roanoke Electric Steel Corp; Administratively continued; issued April 1, 2021, term to March 31, 2026, by VA DEQ; discharges to Roanoke River-Peters Creek.

3 of the 16 pollutants listed for NPDES VA0001589 have no violation or effluent exceedance.

  • Copper, total recoverable: 4 limits, 83 violations of any kind, 83 effluent exceedances, latest June 30, 2026, largest 163% over the limit.
  • Lead, total recoverable: 4 limits, 76 violations of any kind, 76 effluent exceedances, latest December 31, 2014, largest 174% over the limit.
  • Solids, total suspended: 9 limits, 48 violations of any kind, 43 effluent exceedances, latest September 30, 2025, largest 1,140% over the limit.
  • pH: 12 limits, 26 violations of any kind, 15 effluent exceedances, latest June 30, 2026.
  • Chlorine, total residual: 2 limits, 9 violations of any kind, 7 effluent exceedances, latest September 30, 2023, largest 617% over the limit.
  • Temperature, water deg. centigrade: 1 limit, 3 violations of any kind, 3 effluent exceedances, latest March 31, 2025, largest 5% over the limit.
  • Nickel, total recoverable: 0 limits, 3 violations of any kind, 3 effluent exceedances, latest May 31, 2026, largest 52% over the limit.
  • Zinc, total recoverable: 9 limits, 7 violations of any kind, 2 effluent exceedances, latest December 31, 2014, largest 40% over the limit.
  • Length of longest pH excursion: 1 limit, 2 violations of any kind, 2 effluent exceedances, latest August 31, 2025, largest 192% over the limit.
  • Aluminum, total recoverable: 5 limits, 5 violations of any kind.
  • Precipitation volume: 5 limits, 5 violations of any kind.
  • Nickel, dissolved [as Ni]: 4 limits, 2 violations of any kind.
  • .alpha.-Endosulfan: 4 limits, 2 violations of any kind.
  • Oil & Grease: 2 limits.
  • Flow, in conduit or thru treatment plant: 2 limits.
  • pH range excursions, monthly total accum: 1 limit.
  • September 24, 2026: Notice of Violation (State).
  • August 12, 2026: Evaluation (S).
  • August 4, 2026: Letter of Violation/ Warning Letter (State).
  • September 6, 2018: Effluent Violations - Unapproved Bypass (ST6).
  • July 2, 2018: Effluent Violations - Unapproved Bypass (ST6).

RES DBA STEEL DYNAMICS ROANOKE BAR DIVISION among its neighbors

80 discharge permits are in the Peters Creek-Roanoke River subwatershed (HUC 030101010404); VA0001589 is one.

Other permits in the Peters Creek-Roanoke River subwatershed (HUC 030101010404)

What stands out

  • Its term runs 4 years and 364 days, April 1, 2021 to March 31, 2026; the term ended 168 days before EPA's file was loaded on September 15, 2026, and the file lists the permit as administratively continued.
  • Its newest dated event on file is an informal enforcement action on September 24, 2026.
  • In the 365 days to September 15, 2026, it was dated 1 inspection, 1 informal enforcement action.
  • EPA's file dates 5 events for it, from 2018 to 2026; the busiest year is 2026 with 3.
  • 9 of its 16 pollutants on file have an effluent exceedance (56%); 15 are under a numeric limit; the largest exceedance is Solids, total suspended at 1,140% over its limit.
  • It is one of 13,137 discharge permits on the register in Virginia; the file names no program for it, and it is a major discharger.

Identity

FacilityRES DBA STEEL DYNAMICS ROANOKE BAR DIVISION
PermitteeRoanoke Electric Steel Corp
NPDES IDVA0001589
StatusAdministratively continued
TypeIndividual permit
ClassMajor
Facility typeNon-POTW
IssuedApril 1, 2021
ExpiresMarch 31, 2026
AgencyVA DEQ
AddressRoanoke, VA 24017
Receiving waterRoanoke River-Peters Creek
SubwatershedPeters Creek-Roanoke River (HUC 030101010404)
Other EPA IDs (FRS)RCRA handler VAD003122553; ICIS-AIR source VA0000005177000004

NPDES VA0001589: effluent limits and exceedances

RES DBA STEEL DYNAMICS ROANOKE BAR DIVISION (NPDES VA0001589): 16 pollutants on file, 15 limited; 13 with a violation of any kind, 9 with an exceedance.

How exceedances are counted.

PollutantLimitsViolationsExceedancesLatestLargest, as filed
Copper, total recoverable48383June 30, 2026163% over the limit
Lead, total recoverable47676December 31, 2014174% over the limit
Solids, total suspended94843September 30, 20251,140% over the limit
pH122615June 30, 2026
Chlorine, total residual297September 30, 2023617% over the limit
Temperature, water deg. centigrade133March 31, 20255% over the limit
Nickel, total recoverable033May 31, 202652% over the limit
Zinc, total recoverable972December 31, 201440% over the limit
Length of longest pH excursion122August 31, 2025192% over the limit
Aluminum, total recoverable550
Precipitation volume550
Nickel, dissolved [as Ni]420
.alpha.-Endosulfan420
Oil & Grease200
Flow, in conduit or thru treatment plant200
pH range excursions, monthly total accum100

NPDES VA0001589: inspections, violations and enforcement

NPDES VA0001589: 2 single-event violations

DateWhat EPA recordedAgency
September 6, 2018Effluent Violations - Unapproved BypassST6
July 2, 2018Effluent Violations - Unapproved BypassST6

NPDES VA0001589: 1 inspection

DateWhat EPA recordedAgency
August 12, 2026EvaluationS

NPDES VA0001589: 2 informal enforcement actions

DateWhat EPA recordedAgency
September 24, 2026Notice of ViolationState
August 4, 2026Letter of Violation/ Warning LetterState

NPDES VA0001589 (RES DBA STEEL DYNAMICS ROANOKE BAR DIVISION): no formal enforcement action on file.

Watch NPDES VA0001589

NPDES VA0001589: one email when its EPA record changes — $99/month.

Billing

Privacy

Permits near NPDES VA0001589

NPDES VA0001589: 16 pollutant rows, 5 dated events; ICIS-NPDES download, loaded September 15, 2026.