Velarion Records
Free: one email when NPDES VAG830659 changes. Unsubscribe any time.

NPDES VAG830659 · Clean Water Act

ALEXANDRIA CROSSING - SEWER LINE IMPROVEMENT, Alexandria, VA: NPDES VAG830659 discharge permit, effluent exceedances, inspections, penalties

ALEXANDRIA CROSSING - SEWER LINE IMPROVEMENT, Alexandria, Virginia: General permit coverage VAG830659, held by Fairfax County Park Authority; Effective; issued March 1, 2023, term to February 29, 2028, by Virginia; discharges to Cameron Run.

  • pH: 18 limits, 640 violations of any kind.
  • Flow, in conduit or thru treatment plant: 9 limits, 320 violations of any kind.
  • 1,2-Dichloroethane, total weight: 6 limits, 200 violations of any kind.
  • Arsenic, total recoverable: 3 limits, 120 violations of any kind.
  • Selenium, total recoverable: 3 limits, 120 violations of any kind.
  • Thallium, total recoverable: 3 limits, 120 violations of any kind.
  • Nickel, total recoverable: 3 limits, 120 violations of any kind.
  • Silver total recoverable: 3 limits, 120 violations of any kind.
  • Zinc, total recoverable: 3 limits, 120 violations of any kind.
  • Cadmium, total recoverable: 3 limits, 120 violations of any kind.
  • Lead, total recoverable: 3 limits, 120 violations of any kind.
  • Chromium, total recoverable: 3 limits, 120 violations of any kind.
  • Copper, total recoverable: 3 limits, 120 violations of any kind.
  • Antimony, total recoverable: 3 limits, 120 violations of any kind.
  • Carbon tetrachloride: 3 limits, 120 violations of any kind.
  • Chloroform: 3 limits, 120 violations of any kind.
  • Chlorobenzene: 3 limits, 120 violations of any kind.
  • Methylene chloride: 3 limits, 120 violations of any kind.
  • Tetrachloroethylene: 3 limits, 120 violations of any kind.
  • Trichlorofluoromethane: 3 limits, 120 violations of any kind.
  • 1,1-Dichloroethane: 3 limits, 120 violations of any kind.
  • 1,1-Dichloroethylene: 3 limits, 120 violations of any kind.
  • 1,1,1-Trichloroethane: 3 limits, 120 violations of any kind.
  • 1,1,2-Trichloroethane: 3 limits, 120 violations of any kind.
  • 1,2-Dichlorobenzene: 3 limits, 120 violations of any kind.
  • Vinyl chloride: 3 limits, 120 violations of any kind.
  • Trichloroethylene: 3 limits, 120 violations of any kind.
  • Mercury, total recoverable: 3 limits, 120 violations of any kind.
  • cis-1,2-Dichloroethylene: 3 limits, 120 violations of any kind.
  • trans-1,2-Dichloroethylene: 3 limits, 120 violations of any kind.
  • Chloroethane: 3 limits, 120 violations of any kind.
  • Hardness, total [as CaCO3]: 3 limits, 80 violations of any kind.
  • Methyl tert-butyl ether [MTBE]: 3 limits, 80 violations of any kind.
  • Toluene: 3 limits, 80 violations of any kind.
  • Benzene: 3 limits, 80 violations of any kind.
  • Ethylbenzene: 3 limits, 80 violations of any kind.
  • Naphthalene: 3 limits, 80 violations of any kind.
  • Petrol hydrocarbons, total recoverable: 3 limits, 80 violations of any kind.
  • Ethanol: 3 limits, 80 violations of any kind.
  • Ethylene dibromide: 3 limits, 80 violations of any kind.
  • Xylene [mix of m+o+p]: 3 limits, 80 violations of any kind.

Other permits held by Fairfax County Park Authority

ALEXANDRIA CROSSING - SEWER LINE IMPROVEMENT among its neighbors

91 discharge permits are in the Cameron Run subwatershed (HUC 020700100302); VAG830659 is one.

Other permits in the Cameron Run subwatershed (HUC 020700100302)

What stands out

  • Its term runs 4 years and 365 days, March 1, 2023 to February 29, 2028.
  • No dated event in the 365 days to September 15, 2026.
  • It is one of 13,137 discharge permits on the register in Virginia; the file names no program for it, and it is a minor discharger.

Identity

FacilityALEXANDRIA CROSSING - SEWER LINE IMPROVEMENT
PermitteeFairfax County Park Authority
NPDES IDVAG830659
StatusEffective
TypeGeneral permit coverage
ClassMinor
Facility typeNon-POTW
IssuedMarch 1, 2023
ExpiresFebruary 29, 2028
AgencyVirginia
AddressAlexandria, VA 22307
Receiving waterCameron Run
SubwatershedCameron Run (HUC 020700100302)

NPDES VAG830659: effluent limits and exceedances

ALEXANDRIA CROSSING - SEWER LINE IMPROVEMENT (NPDES VAG830659): 41 pollutants on file, 41 limited; 41 with a violation of any kind, 0 with an exceedance.

How exceedances are counted.

PollutantLimitsViolationsExceedancesLatestLargest, as filed
pH186400
Flow, in conduit or thru treatment plant93200
1,2-Dichloroethane, total weight62000
Arsenic, total recoverable31200
Selenium, total recoverable31200
Thallium, total recoverable31200
Nickel, total recoverable31200
Silver total recoverable31200
Zinc, total recoverable31200
Cadmium, total recoverable31200
Lead, total recoverable31200
Chromium, total recoverable31200
Copper, total recoverable31200
Antimony, total recoverable31200
Carbon tetrachloride31200
Chloroform31200
Chlorobenzene31200
Methylene chloride31200
Tetrachloroethylene31200
Trichlorofluoromethane31200
1,1-Dichloroethane31200
1,1-Dichloroethylene31200
1,1,1-Trichloroethane31200
1,1,2-Trichloroethane31200
1,2-Dichlorobenzene31200
Vinyl chloride31200
Trichloroethylene31200
Mercury, total recoverable31200
cis-1,2-Dichloroethylene31200
trans-1,2-Dichloroethylene31200
Chloroethane31200
Hardness, total [as CaCO3]3800
Methyl tert-butyl ether [MTBE]3800
Toluene3800
Benzene3800
Ethylbenzene3800
Naphthalene3800
Petrol hydrocarbons, total recoverable3800
Ethanol3800
Ethylene dibromide3800
Xylene [mix of m+o+p]3800

NPDES VAG830659: inspections, violations and enforcement

NPDES VAG830659 (ALEXANDRIA CROSSING - SEWER LINE IMPROVEMENT): no single-event violation, inspection, formal enforcement action and informal enforcement action on file.

Watch NPDES VAG830659

NPDES VAG830659: one email when its EPA record changes — $99/month.

Billing

Privacy

Permits near NPDES VAG830659

NPDES VAG830659: 41 pollutant rows, 0 dated events; ICIS-NPDES download, loaded September 15, 2026.