Velarion Records
Free: one email when NPDES WAR011515 changes. Unsubscribe any time.

NPDES WAR011515 · Clean Water Act

ADDISON CONSTRUCTION SUPPLY, Tacoma, WA: NPDES WAR011515 discharge permit, effluent exceedances, inspections, penalties

ADDISON CONSTRUCTION SUPPLY, Tacoma, Washington: General permit coverage WAR011515, held by Addison Construction Supply Inc; Administratively continued; issued November 20, 2019, term to December 31, 2024, by State; Fabricated Structural Metal Manufacturing.

  • Zinc, total [as Zn]: 1 limit, 24 violations of any kind, 13 effluent exceedances, latest June 30, 2022, largest 281% over the limit.
  • Copper, total [as Cu]: 1 limit, 14 violations of any kind, 3 effluent exceedances, latest September 30, 2021, largest 123% over the limit.
  • Turbidity: 1 limit, 12 violations of any kind, 1 effluent exceedance, latest June 30, 2022.
  • pH: 2 limits, 22 violations of any kind.
  • Oil and grease visual: 1 limit, 11 violations of any kind.
  • Total Petroleum Hydrocarbons - Diesel: 1 limit, 8 violations of any kind.
  • Lead, total [as Pb]: 1 limit, 7 violations of any kind.
  • Total Petroleum Hydrocarbons - Diesel and Waste Oil: 0 limits, 1 violation of any kind.

ADDISON CONSTRUCTION SUPPLY among its neighbors

91 discharge permits are in the Chambers Creek subwatershed (HUC 171100190303); WAR011515 is one. Its county: 662, 9 major; WAR011515 is minor permit.

Other permits in the Chambers Creek subwatershed (HUC 171100190303)

What stands out

  • Its term runs 5 years and 41 days, November 20, 2019 to December 31, 2024; the term ended 652 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
  • No dated event in the 365 days to October 14, 2026.
  • 3 of its 8 pollutants on file have an effluent exceedance (38%); 7 are under a numeric limit; the largest exceedance is Zinc, total [as Zn] at 281% over its limit.
  • It is one of 8,573 discharge permits on the register in Washington; the file names no program for it, and it is a minor discharger.

Identity

FacilityADDISON CONSTRUCTION SUPPLY
PermitteeAddison Construction Supply Inc
NPDES IDWAR011515
StatusAdministratively continued
TypeGeneral permit coverage
ClassMinor
Facility typeNon-POTW
IssuedNovember 20, 2019
ExpiresDecember 31, 2024
AgencyState
AddressTacoma, WA 98409
SubwatershedChambers Creek (HUC 171100190303)
NAICS332312 – Fabricated Structural Metal Manufacturing
SIC3441 – Fabricated Structural Metal

NPDES WAR011515: effluent limits and exceedances

ADDISON CONSTRUCTION SUPPLY (NPDES WAR011515): 8 pollutants on file, 7 limited; 8 with a violation of any kind, 3 with an exceedance.

How exceedances are counted.

PollutantLimitsViolationsExceedancesLatestLargest, as filed
Zinc, total [as Zn]12413June 30, 2022281% over the limit
Copper, total [as Cu]1143September 30, 2021123% over the limit
Turbidity1121June 30, 2022
pH2220
Oil and grease visual1110
Total Petroleum Hydrocarbons - Diesel180
Lead, total [as Pb]170
Total Petroleum Hydrocarbons - Diesel and Waste Oil010

NPDES WAR011515: inspections, violations and enforcement

NPDES WAR011515 (ADDISON CONSTRUCTION SUPPLY): no single-event violation, inspection, formal enforcement action and informal enforcement action on file.

Watch NPDES WAR011515

NPDES WAR011515: one email when its EPA record changes — $99/month.

Billing

Privacy

Permits near NPDES WAR011515

NPDES WAR011515: 8 pollutant rows, 0 dated events; ICIS-NPDES download, loaded October 14, 2026.