Velarion Records
Free: one email when NPDES WV0115398 changes. Unsubscribe any time.

NPDES WV0115398 · Clean Water Act

ALCON ADVANCED OPTIC DEVICE CENTER (AODC) SOUTH, Huntington, WV: NPDES WV0115398 discharge permit, effluent exceedances, inspections, penalties

ALCON ADVANCED OPTIC DEVICE CENTER (AODC) SOUTH, Huntington, West Virginia: Individual permit WV0115398, held by ALCON RESEARCH, LTD.; Administratively continued; issued June 25, 1999, term to January 27, 2025; discharges to OHIO RIVER.

1 of the 14 pollutants listed for NPDES WV0115398 have no violation or effluent exceedance.

  • pH: 10 limits, 56 violations of any kind, 40 effluent exceedances, latest January 31, 2023.
  • BOD, 5-day, 20 deg. C: 8 limits, 51 violations of any kind, 39 effluent exceedances, latest December 31, 2015, largest 820% over the limit.
  • Coliform, fecal general: 2 limits, 43 violations of any kind, 37 effluent exceedances, latest April 30, 2021, largest 3,400% over the limit.
  • Solids, total suspended: 14 limits, 41 violations of any kind, 19 effluent exceedances, latest December 31, 2020, largest 4,087% over the limit.
  • Chlorine, total residual: 6 limits, 8 violations of any kind, 8 effluent exceedances, latest September 30, 2020, largest 3,471% over the limit.
  • BOD, 5-day, percent removal: 0 limits, 38 violations of any kind, 5 effluent exceedances, latest August 31, 2011, largest 85% over the limit.
  • Nitrogen, Kjeldahl, total [as N]: 4 limits, 17 violations of any kind, 5 effluent exceedances, latest December 31, 2015, largest 401% over the limit.
  • Flow, in conduit or thru treatment plant: 8 limits, 14 violations of any kind, 1 effluent exceedance, latest June 30, 2006, largest 13% over the limit.
  • Solids, suspended percent removal: 0 limits, 33 violations of any kind.
  • Oil and grease, hexane extr method: 10 limits, 10 violations of any kind.
  • Phthalate esters: 6 limits, 2 violations of any kind.
  • Acetone: 4 limits, 2 violations of any kind.
  • Di[2-ethylhexyl] phthalate [DEHP]: 0 limits, 2 violations of any kind.
  • Temperature, water deg. fahrenheit: 4 limits.
  • January 4, 2024: Management Practice Violations - Improper Operation and Maintenance (ST6).
  • January 4, 2024: Management Practice Violations - Failure to Maintain Records (ST6).
  • June 4, 2021: Management Practice Violations - Improper Operation and Maintenance (ST6).
  • October 24, 2017: Management Practice Violations - Improper Operation and Maintenance (ST6).

Other permits held by ALCON RESEARCH, LTD.

ALCON ADVANCED OPTIC DEVICE CENTER (AODC) SOUTH among its neighbors

17 discharge permits are in the Paddy Creek-Ohio River subwatershed (HUC 050901010709); WV0115398 is one. Its county: 53, 1 major; WV0115398 is minor permit.

Other permits in the Paddy Creek-Ohio River subwatershed (HUC 050901010709)

What stands out

  • Its term runs 25 years and 216 days, June 25, 1999 to January 27, 2025; the term ended 625 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
  • Its newest dated event on file is a single-event violation on January 4, 2024, 1,014 days before EPA's file was loaded.
  • No dated event in the 365 days to October 14, 2026.
  • EPA's file dates 4 events for it, from 2017 to 2024; the busiest year is 2024 with 2.
  • 8 of its 14 pollutants on file have an effluent exceedance (57%); 11 are under a numeric limit; the largest exceedance is Solids, total suspended at 4,087% over its limit.
  • It is one of 3,734 discharge permits on the register in West Virginia; the file names no program for it, and it is a minor discharger.

Identity

FacilityALCON ADVANCED OPTIC DEVICE CENTER (AODC) SOUTH
PermitteeALCON RESEARCH, LTD.
NPDES IDWV0115398
StatusAdministratively continued
TypeIndividual permit
ClassMinor
Facility typeNon-POTW
IssuedJune 25, 1999
ExpiresJanuary 27, 2025
AddressHuntington, WV 25702
Receiving waterOHIO RIVER
Receiving water impaired303(D) Listed
SubwatershedPaddy Creek-Ohio River (HUC 050901010709)
SIC3851 – Ophthalmic Goods - Manufacturing
Other EPA IDs (FRS)RCRA handler WVD982701799; ICIS-AIR source WV00001100037

NPDES WV0115398: effluent limits and exceedances

ALCON ADVANCED OPTIC DEVICE CENTER (AODC) SOUTH (NPDES WV0115398): 14 pollutants on file, 11 limited; 13 with a violation of any kind, 8 with an exceedance.

How exceedances are counted.

PollutantLimitsViolationsExceedancesLatestLargest, as filed
pH105640January 31, 2023
BOD, 5-day, 20 deg. C85139December 31, 2015820% over the limit
Coliform, fecal general24337April 30, 20213,400% over the limit
Solids, total suspended144119December 31, 20204,087% over the limit
Chlorine, total residual688September 30, 20203,471% over the limit
BOD, 5-day, percent removal0385August 31, 201185% over the limit
Nitrogen, Kjeldahl, total [as N]4175December 31, 2015401% over the limit
Flow, in conduit or thru treatment plant8141June 30, 200613% over the limit
Solids, suspended percent removal0330
Oil and grease, hexane extr method10100
Phthalate esters620
Acetone420
Di[2-ethylhexyl] phthalate [DEHP]020
Temperature, water deg. fahrenheit400

NPDES WV0115398: inspections, violations and enforcement

NPDES WV0115398: 4 single-event violations

DateWhat EPA recordedAgency
January 4, 2024Management Practice Violations - Improper Operation and MaintenanceST6
January 4, 2024Management Practice Violations - Failure to Maintain RecordsST6
June 4, 2021Management Practice Violations - Improper Operation and MaintenanceST6
October 24, 2017Management Practice Violations - Improper Operation and MaintenanceST6

NPDES WV0115398 (ALCON ADVANCED OPTIC DEVICE CENTER (AODC) SOUTH): no inspection, formal enforcement action and informal enforcement action on file.

Watch NPDES WV0115398

NPDES WV0115398: one email when its EPA record changes — $99/month.

Billing

Privacy

Permits near NPDES WV0115398

NPDES WV0115398: 14 pollutant rows, 4 dated events; ICIS-NPDES download, loaded October 14, 2026.