Velarion Records
The Pay Desk is the free weekly executive pay briefing — one company at a time, every number traceable to a public filing.
You’ll confirm on The Pay Desk’s sign-up page.

Clean Water Act discharge permit · NPDES NM0000124

REEVES ELECTRIC GENERATING STA, Aluquerque, NM: NPDES NM0000124 discharge permit, effluent exceedances, inspections, penalties

REEVES ELECTRIC GENERATING STA, held by PUBLIC SERVICE CO-NM (B, holds NPDES permit NM0000124, which discharges to 5. EPA’s file records it issued August 28, 2009 and expiring September 30, 2014. The status and dates are as EPA’s permit file stood when Velarion loaded it (September 15, 2026); EPA’s free Detailed Facility Report on ECHO carries the permit’s current standing.

Identity

Facility as filedREEVES ELECTRIC GENERATING STA
Permittee as filedPUBLIC SERVICE CO-NM (B
NPDES IDNM0000124
Permit statusAdministratively continued (past its expiration date and still in force until reissued)
Permit typeIndividual permit
Discharger classMinor discharger
Facility typeNot a publicly owned treatment works
IssuedAugust 28, 2009
Expiration dateSeptember 30, 2014
AddressAluquerque, NM 87103
Receiving water5
SubwatershedArroyo de Domingo (HUC 130202030301)

Cited to the EPA ICIS-NPDES permit file (ECHO download).

Effluent limits and exceedances

An effluent exceedance is a discharge monitoring report value over the permit’s numeric limit (EPA’s violation code E90). A violation of any kind also counts a report not filed. Each row is EPA’s own count for that pollutant.

Pollutant or measureLimitsViolations, any kindEffluent exceedancesLatest exceedanceLargest exceedance, as filed
Copper, total [as Cu]2106June 30, 2003352% over the limit
pH291May 31, 2003
Solids, total suspended260
Flow, in conduit or thru treatment plant260
Low Flow Pass/Fail Static Renewal 48Hr Acute Daphnia pulex260
LF Pass/Fail Static Renewal 48Hr Acute Pimephales promelas260
NOAEC Lethal Statis Renewal 48 Hr Acute Daphnia pulex260
NOAEC Lethal Static Renewal 48Hr acute Pimephales promelas260
Coef Of Var Static Renewal 48Hr Acute D. pulex260
Coef Of Var Static Renewal 48Hr Acute Pimephales promelas260
Hardness, total [as CaCO3]040
Zinc, total [as Zn]040
Whole effluent toxicity040
Temperature, water deg. fahrenheit130
Chlorine, total residual130
Chromium, hexavalent dissolved [as Cr]020
Polychlorinated biphenyls [PCBs]020
Alpha gross radioactivity020
Arsenic, total [as As]010
Whole effluent toxicity - retest #1200
Whole effluent toxicity - retest #2200

Cited to the EPA ICIS-NPDES limits and effluent violations files (ECHO download); up to 60 rows shown, most exceedances first.

Inspections, violations and enforcement

EPA’s single-event violation file, as loaded, holds no violation for NPDES NM0000124.

Velarion’s copy of EPA’s ICIS-NPDES files does not include the inspections, formal enforcement actions and informal enforcement actions files, so this page shows none of them. EPA’s free Detailed Facility Report on ECHO lists this permit’s inspections, enforcement actions and penalties.

Cited to the EPA ICIS-NPDES violation, inspection and enforcement files (ECHO download); up to 50 rows of each shown, newest first.

Watch this permit

One permit holder, $99/month. Watch the register for one permit holder and the places and receiving waters tied to its permits. Choose “One permit holder” and enter this permit’s NPDES ID, NM0000124.

Start the watch

How often?
  • One permit holder — $99/month
  • One watershed — $2,990/year
  • One state — $4,990/year
  • The whole register — $18,000/year

How we handle your data → Privacy

EPA publishes a free Detailed Facility Report for every permit on ECHO: its compliance status quarter by quarter, its inspections, and its enforcement actions and penalties. EPA also sends free notices of new inspections and enforcement actions through ECHO Notify; enter NPDES ID NM0000124 there.

Nearby on the register

Figures from EPA’s ICIS-NPDES download, loaded September 15, 2026.